Drug-Coated Balloon Versus Drug-Eluting Stent in Patient With ST-Segment Elevation Myocardial Infarction (DCB-STEMI)
Acute ST-segment elevation myocardial infarction (STEMI) is a life-threatening emergency requiring immediate intervention. The incidence of premature coronary artery disease (PCAD) is rising rapidly in China; its long-term prognosis remains poor and it frequently progresses to acute myocardial infarction, necessitating high-risk therapies such as primary percutaneous coronary intervention (PCI) or coronary artery bypass grafting, thereby imposing enormous economic and psychological burdens on patients and their families. Moreover, the cumulative 6-year rate of death or myocardial infarction after implantation of the latest-generation drug-eluting stents still reaches 15%, and management of stent failure is extremely challenging. Drug-coated balloon (DCB) angioplasty-representing the "leave-nothing-behind" paradigm-is a highly promising option in young subjects. Accumulating clinical evidence demonstrates that DCB provides favorable efficacy across a broad spectrum of lesions, including small-vessel and large-vessel de novo disease, bifurcation lesions, and in-stent restenosis. Nevertheless, high-quality data on the impact of DCB angioplasty in de novo large-vessel disease and in the setting of acute STEMI are still lacking.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Objectives of Study:
Compare the clinical outcomes of drug-coated balloon (DCB) and drug-eluting stent (DES) treatment in patients with ST-segment elevation myocardial infarction (STEMI).
Design of Study:
Investigator-Initiated,Open Label,Prospective,Multicenter,Randomized Clinical Trial.
Patients Selected: This study aims to STEMI patients who have successfully completed lesion pretreatment in multiple medical centers in China. Patients who meet the inclusion criteria and have no exclusion criteria will be randomly assigned 1:1 to the drug coated balloon group and drug eluting stent group, totaling 1244 cases (622 cases per group).
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Jucheng Zhang
- Phone Number: +8618768146640
- Email: jucheng@zju.edu.cn
Study Locations
-
-
Zhejiang
-
Hangzhou, Zhejiang, China
- Recruiting
- Second Affiliated Hospital, School of Medicine, Zhejiang University
-
Contact:
- Chi Liu
- Phone Number: +8615950550839
- Email: liuchi1011@163.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- . Age of Patients ≥18 years old;
- Acute myocardial infarction patients with onset symptoms<48 hours require emergency PCI;
- . Diagnosis: Chest pain and other ischemic symptoms accompanied by ST segment elevation in at least two adjacent leads on electrocardiogram (① V2 or V3 lead: male<40 years ≥ 0.25mV, ≥ 40 years ≥ 0.2mV; Female ≥1.5mV;② Other leads ≥ 1mV), or new left bundle branch block occurs;
- Criminal blood vessels with clear requirements for emergency PCI;
- Coronary artery in situ lesions, with a visual reference lumen diameter of ≥ 2mm and ≤ 4mm; Lesion's length<40mm;
- After thrombus aspiration and pre dilation, the lesion stenosis is ≤ 50% and there is no C-type or above dissection.
- He/she or his/her legal representative voluntarily participates in this study and signs an informed consent form.
Exclusion Criteria:
- The patient has allergies or contraindications to the following medications: Heparin, Aspirin, Clopidogrel, Prasugrel, Ticagrelor, Cilostazol, Indobufen, Contrast Medias (Patients with clear contrast agent allergies such as rash but can be controlled with effective drugs such as glucocorticoids and diphenhydramine in advance can be selected);
- The patient has active pathological bleeding;
- History of significant gastrointestinal or urogenital bleeding or bleeding tendency within 3 months prior to surgery, known coagulation disorders (including heparin induced thrombocytopenia);
- Patients who are pregnant or have the intention to become pregnant during the period of research;
- Non cardiogenic combined lesions show an expected life expectancy of less than one year;
- Left main trunk's stenosis ≥ 50%
- History of coronary artery bypass grafting in the past;
- Intubation or mechanical ventilation status;
- . Cardiogenic Shock
- . Without signature on informed consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: DCB group
STEMI patients undergo revascularization using DCB |
Drug-coated balloon treatment of target lesions in patients with STEMI undergoing percutaneous coronary intervention. |
|
Active Comparator: DES group
STEMI patients undergo revascularization using DES |
Drug-eluting stent treatment of target lesions in patients with STEMI undergoing percutaneous coronary intervention. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Incidence of patient-oriented composite endpoints (POCE) (Direct measurement and coronary angiography)
Time Frame: 12 months
|
POCE including all-cause mortality, any stroke, any myocardial infarction (MI), and any revascularization, will be obtained through follow-up of subjects. |
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Incidence of patient-oriented composite endpoints (POCE) (Direct measurement and coronary angiography)
Time Frame: 36 months, 60 months
|
POCE including all-cause mortality, any stroke, any myocardial infarction (MI), and any revascularization, will be obtained through follow-up of subjects. |
36 months, 60 months
|
|
Incidence of target vessel failure (Direct measurement and coronary angiography)
Time Frame: 12 months
|
Target vessel failure (a composite of cardiac death, target-vessel MI, or target vessel revascularization) will be obtained through follow-up of subjects. |
12 months
|
|
Incidence of all-cause mortality (Direct measurement)
Time Frame: 36 months, 60 months
|
All-cause mortality will be obtained through follow-up of subjects. |
36 months, 60 months
|
|
Incidence of non-fatal MI (Direct measurement)
Time Frame: 36 months, 60 months
|
Non-fatal MI will be obtained through follow-up of subjects. |
36 months, 60 months
|
|
Incidence of any revascularization (coronary angiography)
Time Frame: 36 months, 60 months
|
Any revascularization will be obtained through follow-up of subjects. |
36 months, 60 months
|
|
Incidence of all-cause and cardiac death (Direct measurement)
Time Frame: 12 months, 36 months, 60 months
|
All-cause and cardiac death will be obtained through follow-up of subjects. |
12 months, 36 months, 60 months
|
|
Incidence of any non-fatal MI without peri-procedural MI (Direct measurement)
Time Frame: 12 months, 36 months, 60 months
|
Any non-fatal MI without peri-procedural MI will be obtained through follow-up of subjects. |
12 months, 36 months, 60 months
|
|
Incidence of any non-fatal MI with peri-procedural MI (Direct measurement)
Time Frame: 12 months, 36 months, 60 months
|
Any non-fatal MI with peri-procedural MI will be obtained through follow-up of subjects. |
12 months, 36 months, 60 months
|
|
Incidence of any target vessel/lesion revascularization (Coronary angiography)
Time Frame: 12 months, 36 months, 60 months
|
Any target vessel/lesion revascularization will be obtained through follow-up of subjects. |
12 months, 36 months, 60 months
|
|
Incidence of any non-target vessel/lesion revascularization (Coronary angiography)
Time Frame: 12 months, 36 months, 60 months
|
Any non-target vessel/lesion revascularization will be obtained through follow-up of subjects. |
12 months, 36 months, 60 months
|
|
Incidence of any revascularization (ischemia-driven or all) (Coronary angiography)
Time Frame: 12 months, 36 months, 60 months
|
Any revascularization (ischemia-driven or all) will be obtained through follow-up of subjects. |
12 months, 36 months, 60 months
|
|
Incidence of non-fatal stroke (ischemic and hemorrhagic) (Direct measurement)
Time Frame: 12 months, 36 months, 60 months
|
Non-fatal stroke (ischemic and hemorrhagic) will be obtained through follow-up of subjects. |
12 months, 36 months, 60 months
|
|
CRP and POCE
Time Frame: 12 months, 36 months, 60 months
|
Prognostic value of CRP on POCE |
12 months, 36 months, 60 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Director: Jun Jiang, Second Affiliated Hospital, Zhejiang University, School of Medicine
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Vascular Diseases
- Cardiovascular Diseases
- Pathologic Processes
- Heart Diseases
- Infarction
- Necrosis
- Myocardial Ischemia
- Myocardial Infarction
- Ischemia
- Pathological Conditions, Signs and Symptoms
- ST Elevation Myocardial Infarction
- Equipment and Supplies
- Prostheses and Implants
- Stents
- Drug-Eluting Stents
Other Study ID Numbers
Other Study ID Numbers
- 2024-0936
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.