Modified Nuclear Phacoemulsification in Brown Cataract
Modified Technique for Nuclear Phacoemulsification in Brown Cataractous Nucleus
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The hard nucleus is physiologically immune against water flow from out to inside the nucleus but we discovered that it is not immune against the flow of water from inside the nucleus to outside. So, we are doing phacoemulsification as usual, but we stop when the gutter becomes half the thickness of the nucleus, then we use the tip of the phaco as irrigation for 30 seconds. the nucleus will become softer.
. As we know, the nucleus of the lens has the highest concentration of crystalline (high osmotic pressure), so the water will flow from the center of the nucleus to the outer surface without any resistance, and all adhesions and bonds between lens fibers will be broken at once, and the nucleus becomes softer.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Asyut, Egypt, 71111
- Assiut univercity
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Brown cataract
Exclusion Criteria:
- white cataract
- soft cataract
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Brown cataract
doing phacoemulsification as usual, but we stop when the gutter becomes half the thickness of the nucleus, then we use the tip of the phaco as irrigation for 30 seconds. the nucleus will become softer
|
doing phacoemulsification as usual but we stop when the gutter becomes half the thickness of the nucleus then we use tip of the phaco as irrigation for 30 seconds. the nucleus will become more softer
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
phaco time
Time Frame: 60 seconds
|
time of ultrasound power
|
60 seconds
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 17209067
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.