Effect of Scanning Technology on the Accuracy of Digitally Customized Intraradicular Attachments
Effect of Scanning Technology on the Accuracy of Digitally Customized Intraradicular Attachments: A Cross Overstudy
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Afnan GM Qamar
- Phone Number: 01158902700
- Email: afnan.gamal98@gmail.com
Study Locations
-
-
Giza Governorate
-
Giza, Giza Governorate, Egypt, 12573
- Hospital of October 6 university
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients aged 18-65 years.
- Endodontically treated teeth requiring intra-radicular attachments.
- Adequate oral hygiene .
- Periodontally Compromised Teeth: When some teeth have reduced bone support but can still be maintained as overdenture abutments with proper treatment.
Exclusion Criteria:
- Severely Compromised Remaining Teeth: If the remaining teeth have poor prognosis due to extensive decay or severe periodontal disease.
- Severe Bone Loss Around Abutment Teeth: If the remaining teeth do not provide adequate support, they may fail early, leading to additional complications.
- Severe Malocclusion: Where occlusal discrepancies make overdenture placement difficult.
- Limited inter-arch Space: cann't accommodate the overdenture components. 5 . Poor Oral Hygiene: increase the risk of decay or periodontal issues in retained abutments.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Group I
Indirect scanning by desktop scanner (for the conventional impression)
|
Scanning of intra-radicular impression by desktop scanner
|
|
Experimental: Group II
Intraoral scanning by Intraoral scanner A
|
Direct scanning of the intra-radicular canal by Intraoral scanner A
|
|
Experimental: Group III
Intraoral scanning by Intraoral scanner B
|
Direct scanning of the intra-radicular canal by Intraoral scanner B
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Accuracy
Time Frame: Immediately after scanning.
|
measure accuracy between the dimension of the prepared canal gained by intra-radicular impression and the dimension of the prepared canal directly by two different types of intraoral scanners
|
Immediately after scanning.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Patient-reported comfort
Time Frame: Immediately after impression taking and scanning.
|
Patient-reported comfort (assessed via a Likert scale questionnaire) Scaled from 0-100 The highest score means excellent The lowest score means unsatisfactory
|
Immediately after impression taking and scanning.
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- Effect of Scanning Technology
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.