Optimal Duration of Longitudinal Mechanical Traction in Displaced Radius Fractures: a Prospective Non-inferiority Study (DRF-LUKS)
The goal of this clinical trial is to learn if 1 minute of mechanical traction lines up a broken wrist bone as well as 5 or 10 minutes of traction in adults (18 years and older) who come to the emergency department with a displaced distal radius fracture (a broken wrist with the bone pieces out of place) that needs to be set and put in a cast. The main questions it aims to answer are:
Is the bone position on X-ray after 1 minute of traction no worse than after 5 or 10 minutes? Bone position is measured as wrist tilt, radial inclination, radial height and ulnar variance.
At what point during traction does the bone reach its best position?
There is no separate comparison group. Each participant serves as their own comparison. Researchers will compare X-rays taken before traction and after 1, 5 and 10 minutes of traction in the same participant to see if longer traction improves bone alignment.
Participants will:
Receive standard pain relief and have their arm placed in traction with finger loops and a 5 kg weight, as in usual care Have two extra wrist X-rays (front and side view) after 1 minute and again after 5 minutes of traction, in addition to the standard X-rays before traction and after 10 minutes Have their fracture set and a cast applied as usual. Participation ends when they leave the emergency department, and there are no extra follow-up visits.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Jill I de Bode
- Phone Number: +410412054770
- Email: jilliris.debode@luks.ch
Study Contact Backup
- Name: Bryan JM van de Wall
- Email: bryan.vandewall@luks.ch
Study Locations
-
-
Canton of Lucerne
-
Lucerne, Canton of Lucerne, Switzerland, 6000
- Recruiting
- Luzerner Kantonsspital
-
Contact:
- Bryan JM van de Wall
- Phone Number: +410412054770
- Email: bryan.vandewall@luks.ch
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Age 18 years or older Acute, displaced distal radius fracture (AO/OTA 23-A, 23-B or 23-C) presenting to the Emergency Department and requiring closed reduction with mechanical traction and cast immobilisation Written informed consent
Exclusion Criteria:
Pathological fracture Open distal radius fracture Irreducible fracture requiring immediate operative fixation Previous surgery, previous fracture, or concomitant fracture of the same (ipsilateral) upper extremity Acute neurovascular compromise requiring immediate surgical intervention Inability to provide informed consent (e.g. severe cognitive impairment, dementia, acute substance intoxication, or a language barrier with no interpreter available) Pregnancy (screened per standard ED protocol)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Sequential traction (1, 5 and 10 minutes)
Adults with an acute displaced distal radius fracture receive standard longitudinal mechanical traction, using finger traps on the thumb, index and middle fingers and a 5 kg counterweight. Standard wrist radiographs (PA and lateral) are taken before traction (T0) and after 10 minutes (T3). Two additional study radiographs (PA and lateral) are taken after 1 minute (T1) and 5 minutes (T2) of traction. Each participant serves as their own control. Closed reduction and casting then follow standard care. |
Continuous longitudinal traction with standardized finger traps and a 5 kg weight over a pulley on the emergency department reduction frame, lasting 10 minutes. Wrist radiographs are taken at 1, 5 and 10 minutes of traction. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in volar/dorsal tilt
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of tracti
|
Volar or dorsal tilt of the distal radius (degrees), measured on the lateral wrist radiograph. The difference between time points is compared against a non-inferiority margin of 5 degrees. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of tracti
|
|
Change in radial inclination
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Radial inclination (degrees), measured on the posteroanterior wrist radiograph. The difference between time points is compared against a non-inferiority margin of 5 degrees. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
|
Change in radial height
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Radial height (mm), measured on the posteroanterior wrist radiograph. The difference between time points is compared against a non-inferiority margin of 2 mm. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
|
Change in ulnar variance
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Ulnar variance (mm), measured on the posteroanterior wrist radiograph. The difference between time points is compared against a non-inferiority margin of 2 mm. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Proportion of fractures with acceptable radiological alignment
Time Frame: After 1, 5 and 10 minutes of traction
|
Percentage of participants whose fracture meets acceptable alignment criteria for volar/dorsal tilt, radial inclination, radial height and ulnar variance at each traction time point. |
After 1, 5 and 10 minutes of traction
|
|
Time point of maximal radiological realignment
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
The traction time point (1, 5 or 10 minutes) at which each of the four radiological parameters (volar/dorsal tilt, radial inclination, radial height, ulnar variance) reaches its maximal correction relative to baseline. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
|
Effect of fracture morphology on change in radiological alignment
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Association between fracture type (AO/OTA 23-A, 23-B, 23-C) and baseline displacement, and the change in the four radiological parameters over time. This is analysed with linear mixed-effects models. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
|
Effect of age and sex on change in radiological alignment
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Association between patient age and sex and the change in the four radiological parameters over time. This includes a sex × time interaction, analysed with linear mixed-effects models. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
|
Effect of BMI, forearm circumference, time to presentation and pain on change in radiological alignment
Time Frame: Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Association between BMI, forearm circumference (a proxy for muscle volume), time from injury to emergency department presentation and maximum pain during traction, and the change in volar/dorsal tilt, radial inclination, radial height and ulnar variance over time. Pain is scored on a Numeric Rating Scale (NRS) from 0 (no pain) to 10 (worst pain imaginable). This is analysed with linear mixed-effects models. |
Before traction (0 minutes) and after 1, 5 and 10 minutes of traction
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Court-Brown CM, Caesar B. Epidemiology of adult fractures: A review. Injury. 2006 Aug;37(8):691-7. doi: 10.1016/j.injury.2006.04.130. Epub 2006 Jun 30.
- McQueen M, Caspers J. Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Br. 1988 Aug;70(4):649-51. doi: 10.1302/0301-620X.70B4.3403617.
- Lippuner K, Johansson H, Kanis JA, Rizzoli R. Remaining lifetime and absolute 10-year probabilities of osteoporotic fracture in Swiss men and women. Osteoporos Int. 2009 Jul;20(7):1131-40. doi: 10.1007/s00198-008-0779-8. Epub 2008 Oct 31.
- Walenkamp MM, Goslings JC, Beumer A, Haverlag R, Leenhouts PA, Verleisdonk EJ, Liem RS, Sintenie JB, Bronkhorst MW, Winkelhagen J, Schep NW. Surgery versus conservative treatment in patients with type A distal radius fractures, a randomized controlled trial. BMC Musculoskelet Disord. 2014 Mar 19;15:90. doi: 10.1186/1471-2474-15-90.
- Candela V, Di Lucia P, Carnevali C, Milanese A, Spagnoli A, Villani C, Gumina S. Epidemiology of distal radius fractures: a detailed survey on a large sample of patients in a suburban area. J Orthop Traumatol. 2022 Aug 30;23(1):43. doi: 10.1186/s10195-022-00663-6.
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- BASEC-2026-01751
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.