Safety and Feasibility of an Integrated Fabric-Type Orthosis for Gait and Balance Improvement in Geriatric Patients

November 12, 2026 updated by: Seoul National University Hospital

Safety and Feasibility of an Integrated Fabric- Type Orthosis With Muscle-Mimicking and Proprioception-Enhancing Functions for Improving Gait and Balance in Geriatric Patients: Pilot Clinical Trial

This pilot clinical trial aims to evaluate the safety and feasibility of an integrated fabric-type orthosis with muscle-mimicking and proprioception-enhancing functions in older adults with geriatric conditions affecting gait and balance. The wearable orthosis provides lower-limb assistance through a fabric-based actuation system and vibrotactile proprioceptive stimulation. Thirty participants aged 65 years or older will undergo gait, balance, proprioception, and electromyography assessments under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on. Outcome measures include gait performance, postural sway, one-leg standing balance, joint position sense, muscle activation, physiological responses, fatigue, and device-related adverse events. The study is designed as an exploratory pilot trial to assess the clinical applicability, usability, and safety of the wearable assistive device in geriatric patients.

Study Overview

Status

Recruiting

Conditions

Intervention / Treatment

Study Type

Interventional

Enrollment (Estimated)

30

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • Jongno
      • Seoul, Jongno, South Korea, 03080
        • Recruiting
        • Seoul National University Hospital
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

65 years and older (Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

Eligibility for participation in the study requires that all the following criteria are met:

  1. Age: Participants must be 65 years of age or older.

  2. Comprehension and Compliance: Able to fully understand and comply with the instructions and study procedures.

  3. Mobility-Impacting Conditions: Must have at least one of the following conditions affecting mobility: (1)Sarcopenia:

    • Muscle Strength: Handgrip strength of <28 kg for men and <18 kg for women.
    • Muscle Function: Short Physical Performance Battery (SPPB) score of 8 or less.
    • Muscle Mass: Bioelectrical impedance analysis (BIA) showing muscle mass <7.0 kg/m² for men and <5.7 kg/m² for women. (2)Diabetes:
    • Diagnosed distal symmetric polyneuropathy.
    • Sensory impairments in toes or feet. (3)Knee Osteoarthritis:
    • Kellgren-Lawrence grade ≥2.
    • Persistent pain (≥3 months) with a severity of at least 3 on the Numerical Rating Scale (NRS).

Exclusion Criteria:

Individuals meeting any of the following criteria will be excluded from study participation:

  1. Inability to Consent: Unable to provide informed consent or not willing to participate in the study procedures.

  2. Severe Sensory or Motion Limitations: Including severe visual or vestibular impairments that could increase the risk of falling.

  3. Communication Barriers: Significant hearing, speech, or language problems that would hinder communication with study personnel.

  4. Independent Walking Inability: Cannot walk independently without the aid of a walking device.

  5. Other Significant Diseases or Conditions:

    • Neurological disorders that affect walking ability (e.g., stroke, Parkinson's disease).
    • Orthopedic or musculoskeletal conditions severely affecting lower limb function.
    • Severe cardiovascular conditions including uncontrolled hypertension or heart failure.
    • Respiratory diseases requiring regular oxygen therapy.
    • Active cancer treatment or cancer treatment within the past 3 years (except basal cell carcinoma or localized prostate cancer).
    • Severe psychiatric disorders like schizophrenia or bipolar disorder.
  6. Other Exclusionary Factors:

    • Past severe orthopedic surgeries on lower limbs which might affect gait and mobility.
    • Severe back pain or any other condition affecting mobility not already listed.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Other
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Integrated Fabric-Type Orthosis Evaluation

Participants will undergo gait, balance, proprioception, and electromyography assessments under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on. The wearable fabric-type orthosis provides muscle-mimicking lower-limb assistance and proprioception-enhancing vibrotactile stimulation for gait and balance support in older adults.

A wearable fabric-type lower-limb orthosis integrating muscle-mimicking actuation and proprioception-enhancing vibrotactile stimulation. The device is designed to assist knee and ankle movements during gait and balance activities in older adults with gait and balance impairments. Participants will be evaluated under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on.

Other Names:
  • Soft Exosuit

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Change in Blood Pressure From Before to After Functional Assessment
Time Frame: Immediately before and after the functional assessment at each study visit

Systolic and Diastolic blood pressure will be measured in millimeters of mercury (mmHg) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.

Immediately before and after the functional assessment at each study visit
Change in Heart Rate From Before to After Functional Assessment
Time Frame: Immediately before and after the functional assessment at each study visit

Heart rate will be measured in beats per minute (bpm) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.

Immediately before and after the functional assessment at each study visit
Change in Perceived Exertion From Before to After Functional Assessment
Time Frame: Immediately before and after the functional assessment at each study visit

Perceived exertion will be assessed using the Borg Scale before and after completion of the functional assessment. Higher scores indicate greater perceived exertion.

Immediately before and after the functional assessment at each study visit
Change in Pain Intensity From Before to After Functional Assessment
Time Frame: Immediately before and after the functional assessment at each study visit

Pain intensity will be assessed using the Numeric Rating Scale (NRS) before and after completion of the functional assessment. Scores range from 0 to 10, with higher scores indicating greater pain intensity.

Immediately before and after the functional assessment at each study visit

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
6-Minute Walk Test
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate walking endurance and functional mobility by measuring the maximum walking distance achieved within six minutes.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
10-Meter Walk Test
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To assess gait speed and short-distance walking performance under different orthosis conditions.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
20-Meter Walk Test
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To assess walking speed and gait performance over a longer walking distance.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Surface Electromyography
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate lower-limb muscle activation patterns during walking using surface electromyography (sEMG).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Static One-Leg Standing Balance Test
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate static balance ability by measuring the duration participants can maintain single-leg standing.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Postural Sway
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To assess postural stability during quiet standing using center of pressure (COP)-based balance measurements.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Passive Joint Position Reproduction Test
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate proprioceptive accuracy by measuring passive knee joint position reproduction error.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Active Joint Position Reproduction Test
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate proprioceptive accuracy by measuring active knee joint position reproduction error.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Participant Satisfaction
Time Frame: Immediately post-brace activation (power on)

To assess participant satisfaction, comfort, perceived usability, and overall acceptance of the wearable orthosis.

Immediately post-brace activation (power on)
Gait Speed
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Gait speed measured using the GAITRite system, reported in meters per second (m/s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Cadence
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Cadence measured using the GAITRite system, reported in steps per minute (steps/min).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Step Time
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Step time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Step Length
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Step length measured using the GAITRite system, reported in centimeters (cm).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Stride Time
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Stride time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Stride Length
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Stride length measured using the GAITRite system, reported in centimeters (cm).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Single Support Time
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Single support time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Double Support Time
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Double support time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Stance Time
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Stance time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Swing Time
Time Frame: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Swing time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Collaborators

Investigators

  • Study Director: hyungik shin, prof, Seoul National University Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

June 17, 2026

Primary Completion (Estimated)

December 31, 2027

Study Completion (Estimated)

December 31, 2027

Study Registration Dates

First Submitted

May 21, 2026

First Submitted That Met QC Criteria

November 12, 2026

First Posted (Actual)

November 18, 2026

Study Record Updates

Last Update Posted (Actual)

November 18, 2026

Last Update Submitted That Met QC Criteria

November 12, 2026

Last Verified

May 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • H-2603-077-1726

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.