Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Safety and Feasibility of an Integrated Fabric-Type Orthosis for Gait and Balance Improvement in Geriatric Patients

12. November 2026 aktualisiert von: Seoul National University Hospital

Safety and Feasibility of an Integrated Fabric- Type Orthosis With Muscle-Mimicking and Proprioception-Enhancing Functions for Improving Gait and Balance in Geriatric Patients: Pilot Clinical Trial

This pilot clinical trial aims to evaluate the safety and feasibility of an integrated fabric-type orthosis with muscle-mimicking and proprioception-enhancing functions in older adults with geriatric conditions affecting gait and balance. The wearable orthosis provides lower-limb assistance through a fabric-based actuation system and vibrotactile proprioceptive stimulation. Thirty participants aged 65 years or older will undergo gait, balance, proprioception, and electromyography assessments under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on. Outcome measures include gait performance, postural sway, one-leg standing balance, joint position sense, muscle activation, physiological responses, fatigue, and device-related adverse events. The study is designed as an exploratory pilot trial to assess the clinical applicability, usability, and safety of the wearable assistive device in geriatric patients.

Studienübersicht

Status

Rekrutierung

Bedingungen

Intervention / Behandlung

Studientyp

Interventionell

Einschreibung (Geschätzt)

30

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studienorte

    • Jongno
      • Seoul, Jongno, Südkorea, 03080
        • Rekrutierung
        • Seoul National University Hospital
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

65 Jahre und älter (Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

Eligibility for participation in the study requires that all the following criteria are met:

  1. Age: Participants must be 65 years of age or older.

  2. Comprehension and Compliance: Able to fully understand and comply with the instructions and study procedures.

  3. Mobility-Impacting Conditions: Must have at least one of the following conditions affecting mobility: (1)Sarcopenia:

    • Muscle Strength: Handgrip strength of <28 kg for men and <18 kg for women.
    • Muscle Function: Short Physical Performance Battery (SPPB) score of 8 or less.
    • Muscle Mass: Bioelectrical impedance analysis (BIA) showing muscle mass <7.0 kg/m² for men and <5.7 kg/m² for women. (2)Diabetes:
    • Diagnosed distal symmetric polyneuropathy.
    • Sensory impairments in toes or feet. (3)Knee Osteoarthritis:
    • Kellgren-Lawrence grade ≥2.
    • Persistent pain (≥3 months) with a severity of at least 3 on the Numerical Rating Scale (NRS).

Exclusion Criteria:

Individuals meeting any of the following criteria will be excluded from study participation:

  1. Inability to Consent: Unable to provide informed consent or not willing to participate in the study procedures.

  2. Severe Sensory or Motion Limitations: Including severe visual or vestibular impairments that could increase the risk of falling.

  3. Communication Barriers: Significant hearing, speech, or language problems that would hinder communication with study personnel.

  4. Independent Walking Inability: Cannot walk independently without the aid of a walking device.

  5. Other Significant Diseases or Conditions:

    • Neurological disorders that affect walking ability (e.g., stroke, Parkinson's disease).
    • Orthopedic or musculoskeletal conditions severely affecting lower limb function.
    • Severe cardiovascular conditions including uncontrolled hypertension or heart failure.
    • Respiratory diseases requiring regular oxygen therapy.
    • Active cancer treatment or cancer treatment within the past 3 years (except basal cell carcinoma or localized prostate cancer).
    • Severe psychiatric disorders like schizophrenia or bipolar disorder.
  6. Other Exclusionary Factors:

    • Past severe orthopedic surgeries on lower limbs which might affect gait and mobility.
    • Severe back pain or any other condition affecting mobility not already listed.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Sonstiges
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Integrated Fabric-Type Orthosis Evaluation

Participants will undergo gait, balance, proprioception, and electromyography assessments under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on. The wearable fabric-type orthosis provides muscle-mimicking lower-limb assistance and proprioception-enhancing vibrotactile stimulation for gait and balance support in older adults.

A wearable fabric-type lower-limb orthosis integrating muscle-mimicking actuation and proprioception-enhancing vibrotactile stimulation. The device is designed to assist knee and ankle movements during gait and balance activities in older adults with gait and balance impairments. Participants will be evaluated under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on.

Andere Namen:
  • Soft Exosuit

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Change in Blood Pressure From Before to After Functional Assessment
Zeitfenster: Immediately before and after the functional assessment at each study visit

Systolic and Diastolic blood pressure will be measured in millimeters of mercury (mmHg) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.

Immediately before and after the functional assessment at each study visit
Change in Heart Rate From Before to After Functional Assessment
Zeitfenster: Immediately before and after the functional assessment at each study visit

Heart rate will be measured in beats per minute (bpm) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.

Immediately before and after the functional assessment at each study visit
Change in Perceived Exertion From Before to After Functional Assessment
Zeitfenster: Immediately before and after the functional assessment at each study visit

Perceived exertion will be assessed using the Borg Scale before and after completion of the functional assessment. Higher scores indicate greater perceived exertion.

Immediately before and after the functional assessment at each study visit
Change in Pain Intensity From Before to After Functional Assessment
Zeitfenster: Immediately before and after the functional assessment at each study visit

Pain intensity will be assessed using the Numeric Rating Scale (NRS) before and after completion of the functional assessment. Scores range from 0 to 10, with higher scores indicating greater pain intensity.

Immediately before and after the functional assessment at each study visit

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
6-Minute Walk Test
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate walking endurance and functional mobility by measuring the maximum walking distance achieved within six minutes.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
10-Meter Walk Test
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To assess gait speed and short-distance walking performance under different orthosis conditions.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
20-Meter Walk Test
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To assess walking speed and gait performance over a longer walking distance.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Surface Electromyography
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate lower-limb muscle activation patterns during walking using surface electromyography (sEMG).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Static One-Leg Standing Balance Test
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate static balance ability by measuring the duration participants can maintain single-leg standing.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Postural Sway
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To assess postural stability during quiet standing using center of pressure (COP)-based balance measurements.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Passive Joint Position Reproduction Test
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate proprioceptive accuracy by measuring passive knee joint position reproduction error.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Active Joint Position Reproduction Test
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

To evaluate proprioceptive accuracy by measuring active knee joint position reproduction error.

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Participant Satisfaction
Zeitfenster: Immediately post-brace activation (power on)

To assess participant satisfaction, comfort, perceived usability, and overall acceptance of the wearable orthosis.

Immediately post-brace activation (power on)
Gait Speed
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Gait speed measured using the GAITRite system, reported in meters per second (m/s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Cadence
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Cadence measured using the GAITRite system, reported in steps per minute (steps/min).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Step Time
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Step time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Step Length
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Step length measured using the GAITRite system, reported in centimeters (cm).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Stride Time
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Stride time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Stride Length
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Stride length measured using the GAITRite system, reported in centimeters (cm).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Single Support Time
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Single support time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Double Support Time
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Double support time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Stance Time
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Stance time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
Swing Time
Zeitfenster: 1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Swing time measured using the GAITRite system, reported in seconds (s).

1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Mitarbeiter

Ermittler

  • Studienleiter: hyungik shin, prof, Seoul National University Hospital

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

17. Juni 2026

Primärer Abschluss (Geschätzt)

31. Dezember 2027

Studienabschluss (Geschätzt)

31. Dezember 2027

Studienanmeldedaten

Zuerst eingereicht

21. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

12. November 2026

Zuerst gepostet (Tatsächlich)

18. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

18. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

12. November 2026

Zuletzt verifiziert

1. Mai 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • H-2603-077-1726

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .