Computational Design, Fabrication, and Evaluation of Optimized Patient-Specific Transtibial Prosthetic Sockets

September 28, 2022 updated by: Massachusetts Institute of Technology
The overall goal of this study is to further develop and clinically assess a computational and data-driven design and manufacturing framework for mechanical interfaces that quantitatively produces transtibial prosthetic sockets in a faster and more cost-effective way than conventional processes. The main hypothesis of this proposal is that the novel quantitative interface is equivalent to, or better than, a conventional interface in terms of: 1) gait symmetry, 2) skin contact pressures, 3) skin surface temperature, and 4) comfort as evaluated from a questionnaire.

Study Overview

Status

Completed

Conditions

Detailed Description

Title: Computational Design, Fabrication, and Evaluation of Optimized Patient-Specific Transtibial Prosthetic Sockets

Principle Investigator: Dr. Hugh Herr

Background: The overall goal of this application is to further develop and clinically assess a computational and data-driven design and manufacturing framework for mechanical interfaces that quantitatively produces transtibial prosthetic sockets in a faster and more cost-effective way than conventional processes. Traditionally, prosthetic socket production has been a craft activity, based primarily on the experience of the prosthetist. Even with advances in computer-aided design and computer-aided manufacturing (CAD/CAM), the design process remains manual. The manual nature of the process means it is non-repeatable and currently largely non-data-driven, and quantitative data is either not obtained or insufficiently employed. Furthermore, discomfort, skin problems and pressure ulcer formation remain prevalent. Through the proposed computational modeling framework, a repeatable, data-driven and patient-specific design process is made available which is based on scientific rationale.

Objective/hypothesis: The main hypothesis of this proposal is that a socket, designed using the novel computational design framework, is equivalent to, or better than, a conventional socket (designed by a prosthetist) in terms of: 1) gait symmetry, 2) skin contact pressures, 3) skin surface temperature, and 4) comfort as evaluated from a questionnaire. Our hypothesis is supported by the presented pilot data which shows reduced or equivalent skin contact pressures and subject reported comfort levels for several critical anatomical regions.

Specific Aims: 1) Subject-specific biomechanical modeling for N=18 subjects, 2) Computational design and fabrication of sockets for N=18 subjects, and 3) Clinical evaluation of novel sockets for N=18 subjects.

Study Design: A cohort of 18 subjects will be recruited for this study. MRI or CT data will be recorded for all subjects. Through image segmentation geometrically accurate 3D finite element analysis (FEA) models will be constructed. The resulting predictive FEA models will then be used in a novel, data-driven, and automated computational design framework for prosthetic sockets, to design prosthetic sockets for all subjects. The framework optimizes the socket designs, as assessed by skin contact pressures and internal tissue strain, through iterative adjustment of the virtual tests sockets. Final designs are subsequently 3D printed. To evaluate the prosthetic sockets with each of the subjects each subject will do a standing and walking exercise using their conventional sockets or the novel sockets. Meanwhile skin contact pressures and temperatures are recorded, gait symmetry data is collecetd, and socket comfort is assessed using a questionnaire. Together this data provides a quantitative and qualitative evaluation and comparison of the novel and conventional sockets.

Study Type

Interventional

Enrollment (Actual)

10

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Jalisco
      • Nuevo Mexico, Jalisco, Mexico, 45201
        • Tecnologico de Monterrey, Biomechatronics Lab
    • Massachusetts
      • Cambridge, Massachusetts, United States, 02142
        • Massachusetts Institute of Technology, Media Lab

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 64 years (Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Age: 18-64 years old
  • Amputation type: Transtibial amputation (bilateral or unilateral) which took place >1 year prior to study
  • Activity or K-level: At least K3
  • Socket quality: The subject's conventional socket(s) should be deemed of high quality and comfortable
  • MRI safety: Subjects should be able to undergo MRI

Exclusion Criteria:

-

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Basic Science
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Prosthetic socket evaluation
Intervention: Prosthetic socket for transtibial amputee. A subject's conventional prosthetic socket is compared to a novel prosthetic socket designed as part of the research. For standing and walking exercises the following will be assessed. 1) local skin contact pressures, 2) metabolic power, 3) gait parameters (symmetry indices for joint angles, positions, torques, and also ground reaction forces), and 4) the socket evaluation questionnaire.
To wear a prosthetic socket for evaluation of comfort and biomechanical metrics such as skin loading conditions.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Local skin pressure while wearing a socket
Time Frame: Assessed once during (clinical) socket comfort evaluation phase. Measurements are for standing and walking exercises for the conventional and novel socket.
Local skin contact pressures (in Newton per square meter) are assessed using pressure sensors positioned on the skin surface. Local pressures relate to comfort which is the topic of investigation. These measurements are performed during the (clinical) socket comfort evaluation phase which is typically 3 months after the initial data acquisition phase for each subject. Measurements take place once and in a single session. As such only a single time point is investigated (the time point of the experiment is not a relevant or investigated parameter). The data is compared across subjects and socket types.
Assessed once during (clinical) socket comfort evaluation phase. Measurements are for standing and walking exercises for the conventional and novel socket.
Skin surface temperature difference
Time Frame: Assessed once during (clinical) socket comfort evaluation phase. Measurements are for standing and walking exercises for the conventional and novel socket.
Skin surface temperatures (in Celsius) are assessed using a Flir thermal camera, with images taken immediately post-kinematic walking trial. From these measurements the average residuum skin surface temperature is assessed for 4 different view directions: anterior, posterior, medial, and lateral. Measurements take place once and in a single session. As such only a single time point is investigated (the time point of the experiment is not a relevant or investigated parameter). The data is compared across subjects and socket types.
Assessed once during (clinical) socket comfort evaluation phase. Measurements are for standing and walking exercises for the conventional and novel socket.
Gait parameter asymmetry
Time Frame: Assessed once during (clinical) socket comfort evaluation phase. Measurements are for standing and walking exercises for the conventional and novel socket.
Socket fit (and discomfort) influences musculoskeletal behavior and may alter gait patterns. Subjects are equipped with markers tracked (units of mm) using a motion capture system (T40s, Vicon Motion Systems Ltd, Oxford, UK). Ground reaction forces (units Newton) are also recorded. From these measurements gait symmetry indices for: joint angles, positions, torques, and ground reaction forces, are computed. These measurements are performed during the (clinical) socket comfort evaluation phase which is typically 3 months after the initial data acquisition phase for each subject. Measurements take place once and in a single session. As such only a single time point is investigated (the time point of the experiment is not a relevant or investigated parameter). The data is compared across subjects and socket types.
Assessed once during (clinical) socket comfort evaluation phase. Measurements are for standing and walking exercises for the conventional and novel socket.
Socket evaluation questionnaire
Time Frame: Assessed once during (clinical) socket comfort evaluation phase. Measurements are for sitting, standing and walking exercises for the conventional and novel socket.
Socket fit and discomfort is assessed using a questionnaire created to document patient experiences and preferences while using prosthetic interfaces (liners, sockets) both over a longitudinal timeline and on an immediate basis. After establishing subject baselines for socket use, patients complete a section that instructs them to evaluate the novel prosthetic socket provided against their conventional prosthetic socket. Subjects complete the questionnaire via a HIPAA compliant surveying instrument on Redcap, and questions are tailored to minimize bias through adoption of verified metrics (such as those from the TAPES-R instrument) or by the use of sliding scales that eliminate the need for constrained integer number input. The data is analyzed by subject, across subjects as a whole, and socket types.
Assessed once during (clinical) socket comfort evaluation phase. Measurements are for sitting, standing and walking exercises for the conventional and novel socket.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Hugh M Herr, PhD, Massachusetts Institute of Technology, Media Lab

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

September 15, 2017

Primary Completion (Actual)

August 31, 2022

Study Completion (Actual)

August 31, 2022

Study Registration Dates

First Submitted

April 19, 2018

First Submitted That Met QC Criteria

May 21, 2018

First Posted (Actual)

June 4, 2018

Study Record Updates

Last Update Posted (Actual)

September 30, 2022

Last Update Submitted That Met QC Criteria

September 28, 2022

Last Verified

September 1, 2022

More Information

Terms related to this study

Other Study ID Numbers

  • 1101004280
  • R01EB024531-01 (U.S. NIH Grant/Contract)

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Amputation Stump

Clinical Trials on Prosthetic socket for transtibial amputee

Subscribe