- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05978947
Microfluidic Chip Method Versus Density Gradient Centrifugation Method on Semen Parameters
Effect of Sperm Preparation by a Microfluidic Chip Method Versus a Density Gradient Centrifugation Method on Semen Parameters
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Infertility affects one in six couples and is getting more common as many women delay marriage and childbirth for various reasons. In vitro fertilization (IVF) is the most effective treatment for couples with long standing infertility and has treated millions of infertile couples over the world since the first birth of IVF was reported more than 40 years ago. However, despite advances in technology, the pregnancy and birth rates remain around 35% and 25% per transfer in Europe in 2018. Among all infertile couples, 20-30% are due to male infertility. Semen parameters may affect the IVF outcomes and it was hypothesized that the relative contribution of sperm to a live birth is around 10-15%.
IVF involves hormone injections to stimulate a woman's ovaries to produce a number of oocytes which are collected by a minor operation and then mixed with sperm to form embryos in the laboratory. Usually, one or two embryos are transferred to the uterus 2-5 days after oocyte retrieval. In IVF, semen samples produced by husbands are commonly processed by a density gradient centrifugation method to isolate the better spermatozoa for fertilization. The density gradient centrifugation can enrich spermatozoa with relatively good motility and normal morphology. It is possible to recover spermatozoa from semen specimens with a very low sperm density. It can provide a relatively good yield. However, it requires technical training to set up the density gradient consisting of two media with different densities. During semen processing, spermatozoa are centrifuged through the gradient. It is known that centrifugation causes considerable damage to spermatozoa by the reactive oxygen species produced during the process. Reactive oxygen species are known to be one of the major causes leading to sperm DNA fragmentation and subsequent adverse outcomes including implantation failure and miscarriage. A meta-analysis showed sperm DNA damage has a negative effect on clinical pregnancy following IVF.
A microfluidic chip, which is a miniaturized device containing channels and chambers in the microscale range for nanoparticle preparation, is being used as an alternative sperm preparation technique recently. By employing microfluidic technology, spermatozoa can go through the chip that closely simulates the natural selection in the female genital tract microenvironment. The technology enables the selection of high-quality motile spermatozoa from semen samples without the need for centrifugation, leading to reduced reactive oxygen species formation.
Studies have consistently demonstrated that the use of a microfluidic chip method greatly reduces DNA fragmentation and increases motility when compared with the density gradient centrifugation method.
This randomized controlled trial aims compare the effect of sperm preparation by a microfluidic chip method versus a density gradient centrifugation method on semen parameters prior to the start of a randomized trial comparing the effects of the two sperm preparation methods on the cumulative live birth rates of in vitro fertilization.
Objectives:
The first objective of this randomized controlled trial is to compare the effect of sperm preparation by a microfluidic chip method versus a density gradient centrifugation on semen parameters. The hypothesis is that the use of sperm preparation by a microfluidic chip method improves semen parameters.
The second objective is to compare the effect of two different microfluidic chip platforms on semen parameters.
Trial design:
Men attending at the Centre of Assisted Reproduction and Embryology, Queen Mary Hospital for fertility treatment will be recruited.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: YU WING TONG, MBBS
- Phone Number: 92707722
- Email: ptong@connect.hku.hk
Study Locations
-
-
Hong Kong
-
Hong Kong, Hong Kong, China
- Recruiting
- Department of Obstetrics and Gynaecology
-
Contact:
- Ernest HY NG, MD
- Phone Number: 852-22553400
- Email: nghye@hku.hk
-
Principal Investigator:
- Ernest HY NG, MD
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Sperm concentration of the raw semen with at least 5 million motile sperm per ml with a total volume of not less than 1.5ml.
Exclusion Criteria:
- Sperm concentration of the raw semen of less than 5 million motile sperm per ml
- Men unable to provide an ejaculated semen sample
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Quadruple
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Microfluidic Chip Method
The Sperm Separation Device - ZyMōt Multi 850µL device (ZyMōt Fertility, Inc) will be used.
The microfluidic chamber will be used based on the manufacturer's instructions.
850 μL of the semen sample will be added to the inlet port of the device and 750 μL of fertilization media will be added to the outlet port.
The device will then be incubated in 6% CO2 at 37°C.
After 30 minutes, 500 μL of the prepared sample at the outlet port will be removed and pipetted into a labelled test tube.
The final volume will be adjusted to 1mL for sperm counting.
|
The ZyMōt Multi 850µL device is a laboratory tool designed for use in assisted reproductive technology (ART) procedures such as intrauterine insemination (IUI) and in vitro fertilization (IVF).
It is a sperm preparation device that uses a proprietary patented technology to isolate and select motile sperm from semen samples for use in ART procedures.
|
|
Active Comparator: Density Gradient Centrifugation Method
After liquefaction, sperm preparation will be completed by a discontinuous density gradient centrifugation method, using Pureception (CooperSurgical, Denmark) sperm density gradient media.
The resulting sperm pellet after centrifugation will be washed once with the sperm washing medium (G-IVF Plus, Vitrolife, Sweden) The washed spermatozoa will be resuspended with the same medium, adjusting the final volume to 500 μL.
The final volume will be adjusted to 1mL for sperm counting.
|
Density gradient centrifugation is a laboratory technique used to separate and isolate different types of cells or particles based on their density.
It is commonly used in various applications, including cell biology, immunology, and assisted reproductive technology (ART).
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
DNA fragmentation by Comet assay
Time Frame: 1 months
|
Measurement of DNA fragmentation by Comet assay using the Olive tail moment as the quantitative metric.
|
1 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Sperm count
Time Frame: 1 months
|
Sperm count
|
1 months
|
|
Forward motility
Time Frame: 1 months
|
Assessment of forward motility of sperm by manual observation using the World Health Organization (WHO) criteria.
|
1 months
|
|
Morphology
Time Frame: 1 months
|
Quantitative assessment of sperm morphology by manual observation using the Tygerberg strict criteria.
|
1 months
|
|
Sperm aneuploidy
Time Frame: 1 months
|
Quantitative measurement of sperm aneuploidy by fluorescence in situ hybridization (FISH) using probes for chromosomes X, Y, 13, 18, and 21.
|
1 months
|
|
Calcium ionophore A23187 -induced acrosome reaction assay
Time Frame: 1 months
|
Quantitative measurement of acrosome reaction in sperm induced by calcium ionophore A23187 using flow cytometry.
|
1 months
|
|
Intact oocyte/hemizona binding assay
Time Frame: 1 months
|
Quantitative measurement of sperm binding to intact oocytes or hemizona using the intact oocyte/hemizona binding assay.
|
1 months
|
|
Sperm velocities measured by CASA
Time Frame: 1 months
|
Quantitative analysis of sperm velocities using computer-assisted sperm analysis (CASA) system, including assessment of forward motility, curvilinear velocity, and linearity.
|
1 months
|
|
Artificial intelligence analysis
Time Frame: 1 months
|
Quantitative analysis of sperm morphology using artificial intelligence algorithms.
|
1 months
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Estimated)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- UW 23-233
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.