Safety and Efficacy of Pulsed-field Ablation for Atrial Fibrillation in High Versus Low-volume Ablation Centers (SAFFICIENT) (SAFFICIENT)

Safety and Efficacy of Pulsed-field Ablation for Atrial Fibrillation in High Versus Low-volume Ablation Centers

Catheter ablation using radiofrequency (RF) energy has been widely adopted for management of atrial fibrillation (AF) for the past several years.

However, heterogeneity of outcomes and complication rates are still reported that have been partly attributed to operator's experience and center's procedure volume (1). In a meta-analysis of 14 studies, both hospital volume of ≥50 and ≥100 procedures per year were associated with significantly lower complication rate compared to <50/year (2).

Pulse-field ablation (PFA) is an emerging technology for AF management that has demonstrated tremendous potential in terms of preferential tissue ablation with no damage to the adjacent organs. In the MANIFEST-PF survey, 24 European centers participated that had a mean of 704 ablations per year with 73.3 (range 7-291) PFA ablations annually (3). No post-PFA esophageal complications, PV stenosis or persistent phrenic nerve injury were reported. There appeared to be a trend toward fewer complications with center experience, particularly for pericardial tamponade (3).

However, the impact of number of PFA performed on procedure-success and safety has not been evaluated in the US.

This multicenter prospective study is designed to compare the incidence of adverse event (AE) and long-term procedural success of pulse-field ablation for AF in low volume (<100/year) vs. high volume (≥100/year) centers.

Study Overview

Detailed Description

Prospective, non-randomized, multi-center study NUMBER OF STUDY CENTERS: Up to 80 TRIAL OBJECTIVE To evaluate safety of the VARIPULSE™ Catheter when used in conjunction with the TRUPULSE™ Generator for catheter ablation in low volume centers, compared to high-volume centers, for the treatment of subjects with symptomatic atrial fibrillation, excluding long-standing persistent AF.

HYPOTHESIS The low volume centers would be noninferior to high volume centers with respect to the proportion of patients experiencing at least one primary adverse event (PAE).

ABLATION PROCEDURE All left atrial ablations such as pulmonary vein isolation (PVI) and isolation of left atrial posterior wall will be performed using the PFA system. If the right atrial structures are needed to be ablated (i.e. cavotricuspid isthmus line, coronary sinus), a commercially approved radiofrequency (RF) catheter and compatible RF generator will be used.

MANDATORY: Minimum applications per vein is 12, Maximum applications per vein is 20 Ablation Outside the PV

Ablation outside the PVs will be performed only in the presence of spontaneous triggers or documentation that those locations are the sites for triggers responsible for re-initiation of the arrhythmia either spontaneously or after isoproterenol challenge. For ablation outside the pulmonary vein, the number of applications will be determined on a case- by-case basis based on the expected tissue thickness in the ablation area. At a minimum, at least 6 applications per area (3 applications at 2 catheter rotations) should be considered. Each lesion set attempted will be assessed for acute efficacy (bi-directional block, absence of detectable electrograms). Additional lesions should be given until the acute endpoint is met.

Posterior wall ablations: Concentric overlapping ablations should be placed onto the posterior wall deliberately. The catheter will be rotated once between a pair of applications; briefly, rotation is performed such that, post-rotation, the splines are situated midway between the splines' pre- rotation positions. The number of applications will be at the operator's discretion.

DURATION OF SUBJECT PARTICIPATION:

11 months after the index ablation procedure (2 months blanking + 9 months follow-up)

DURATION OF STUDY 2-3 years (1-2 year of enrollment+ 11 months of study duration)

STATISTICS

The sample size and power calculation were performed to establish noninferiority (NI) of low volume centers with respect to the primary safety endpoint. With a NI margin of 0.04, an estimated sample size of 1084 patients per group will provide 80% power at one-sided significance level of 2.5% to declare non-inferiority. Considering 5% oversampling for attrition, 1138 patients will be enrolled per group.

Interim analysis: None planned

Study Type

Observational

Enrollment (Actual)

75

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Texas
      • Austin, Texas, United States, 78705
        • Texas Cardiac Arrhythmia

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Sampling Method

Non-Probability Sample

Study Population

Patients with atrial fibrillation

Description

Inclusion Criteria:

  • Age: >≥18 years

    • Symptomatic Paroxysmal or Persistent AF patients of ≤ 1 year
    • First ablation or redo procedure to treat AF
    • Willing to provide written informed consent
    • Able and willing to comply with all testing and requirements

Exclusion Criteria:

  • Long-standing persistent AF Page 17 of 70

    • Any condition contraindicating chronic anticoagulation
    • Prosthetic mechanical valves
    • Recent MI (in <3 months)
    • Active systemic infection
    • Pregnant or lactating women
    • Current enrollment in an investigational study evaluating another device or drug.
    • Documented left atrial (LA) thrombus by imaging within 48 hours before procedure (computed tomography (CT), transesophageal echocardiogram (TEE), or intracardiac echocardiogram (ICE) at the beginning of the procedure).
    • Uncontrolled heart failure or New York Heart Association (NYHA) Class IV
    • Significant congenital anomaly or medical problem that in the opinion of the investigator would preclude enrollment in this study
    • Life expectancy less than 12 months

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Safety of PFA
Time Frame: 1 year
Adverse events
1 year

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Efficacy of PFA
Time Frame: 2-mo blanking period+ 11 months
Arrhythmia-free on- or off-antiarrhythmic drugs
2-mo blanking period+ 11 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Andrea Natale, Texas Cardiac Arrhythmia Institute, St.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

August 29, 2024

Primary Completion (Actual)

April 4, 2025

Study Completion (Actual)

April 4, 2025

Study Registration Dates

First Submitted

June 24, 2024

First Submitted That Met QC Criteria

June 28, 2024

First Posted (Actual)

July 5, 2024

Study Record Updates

Last Update Posted (Actual)

May 28, 2025

Last Update Submitted That Met QC Criteria

May 21, 2025

Last Verified

May 1, 2025

More Information

Terms related to this study

Other Study ID Numbers

  • TCAI_SAFFICIENT

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Atrial Fibrillation

Clinical Trials on Catheter ablation using pulsed-field ablation (PFA) system

Subscribe