- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06671171
Wearable Assessment of Thoracic, Cardiac Health and Exercise Performance Trial (WATCH-X)
Wearable health technology, particularly smartwatches, has revolutionized personal health monitoring by enabling continuous, non-invasive tracking of various physiological parameters. The potential applications of these devices in cardiology are extensive, but it is crucial to validate their accuracy against established medical-grade devices.
The Apple Watch Series 9 (Apple, USA) exemplifies the capabilities of modern smartwatches, offering a wide range of health tracking features. These include heart rate monitoring, detection of irregular heart rhythms suggestive of atrial fibrillation, electrocardiogram recording, blood oxygen level measurement, and comprehensive mobility metrics (including VO2 max, six-minute walk distance, walking speed, step length, double support time, and walking asymmetry). Many of these parameters are highly relevant for cardiovascular patients, potentially aiding in disease progression monitoring and adverse event prediction. However, there is a lack of comprehensive validation studies for these devices in specific cardiovascular disease populations.
This investigator-initiated prospective observational study involving 50-100 participants that aims to validate smartwatchbased assessments using medical-grade devices and techniques. The study will focus on adult patients with congenital heart disease, pulmonary hypertension, heart failure, and coronary artery disease, as well as athletes undergoing cardiovascular assessment. By comparing smartwatch data with established clinical measurements, the investigators seek to determine the reliability and potential clinical utility of these wearable devices in diverse cardiovascular contexts. This research will help bridge the gap between consumer-grade wearable technology and clinical practice in cardiology.
Study Overview
Status
Intervention / Treatment
Detailed Description
Trial participants from Queen Mary Hospital and the University of Hong Kong will be recruited. Potential participants will be contacted and provided with a detailed explanation of the study, including its purpose, procedures, risks, and benefits. Written informed consent will be obtained from all participants before enrolment. This process involves providing individuals with the informed consent document, allowing time for review and questions, and obtaining their signature if they agree to participate. Participants will receive a copy of the signed consent form for their records.
At Visit 1, Comprehensive demographic and clinical data will be collected from each participant, Clinical Management System (CMS), Electronic Patient Record (ePR), and Clinical Data Analysis and Reporting System (CDARS) of the Hospital Authority in Hong Kong. This will include age, sex, height, weight, body mass index, and detailed medical history focusing on cardiovascular conditions. Information about current medications and smoking status will also be recorded. Additionally, participants will undergo a baseline clinical examination, including blood pressure measurement, heart rate, and a 12-lead electrocardiogram.
Participants will undergo a conventional cardiopulmonary exercise test (CPX) to determine their maximal oxygen uptake (VO2max) at Visit 1. This test will be conducted in a controlled clinical setting under the supervision of cardiologists. Participants will exercise on a treadmill while their respiratory gas exchange is measured using a metabolic cart. The exercise intensity will be gradually increased until the participant reaches volitional exhaustion or predetermined safety criteria are met. The highest oxygen uptake value achieved during the test will be recorded as the VO2max. Participant will concurrently be wearing the investigational smartwatch for pre- and post-SaO2 and VO2max assessment. This gold-standard measurement will serve as the reference for validating the smartwatch's continuous VO2max estimation.
The 6-minute walk distance will be assessed in a hospital setting at Visit 2 under the supervision of a research staff. Participants will be instructed to walk as far as possible in six minutes along a predetermined course, typically a straight hallway. The total distance walked will be measured and recorded. During the test, the research nurse will monitor the participant's heart rate, blood oxygen saturation, and perceived exertion at regular intervals. Participant will concurrently be wearing the investigational smartwatch for pre- and post SaO2 and VO2max assessment.
Participants will be provided with a medical-grade pulse oximeter for home use. They will be instructed to measure their oxygen saturation once daily throughout the one-week study period. Measurements should be taken at approximately the same time each day, preferably in the morning after waking and before any strenuous activity. Participants will record their oxygen saturation readings in a provided log. These daily measurements will serve as reference points for validating the continuous oxygen saturation data collected by the smartwatch.
Study Type
Enrollment (Actual)
Contacts and Locations
Study Locations
-
-
-
Hong Kong, Hong Kong
- Department of Medicine Queen Marry Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Age 20 to 70 years old
- Ability to provide informed consent
- History of the following cardiovascular conditions
- Adult congenital heart disease
- Pulmonary hypertension
- Heart failure
- Coronary artery disease
- Athletes undergoing cardiovascular assessment
Exclusion Criteria:
- Contraindication for undergoing physical exertion including cardio-pulmonary exercise testing (CPX) and 6-minute walk test (6MWT)
- Pregnancy
- Known allergy to components of the investigational product
Study Plan
How is the study designed?
Design Details
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
WatchX
Participants will wear the investigational smartwatch (Apple Watch Series 9) concurrently for pre- and post-SaO2 and VO2max assessment during cardiopulmonary exercise test at Visit 1. Through one-week study period, participants will record their oxygen saturation data collected by the smartwatch once daily in a provided log, preferably in the morning after waking and before any strenuous activity. At Visit 2, participants will walk for a 6-Minute walk test and wear the investigational smartwatch (Apple Watch Series 9) concurrently for pre- and post-SaO2 and VO2max assessment during assessment. |
Participants will wear Apple Watch Series 9 during cardiopulmonary exercise test (in Visit 1), 1-week study period and 6-Minute walk distance test (in Visit 2) to have assessment of maximal oxygen uptake and pre- and post-SaO2. During 1-week study period, participants will measure their oxygen saturation once daily with a medical-grade pulse oximeter while wearing the smartwatch continuously. |
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Correlation between CPX VO2max and smartwatch parameters (virtual VO2 max, physical activity parameters)
Time Frame: During treadmill exercise in the day of recruitment and concurrently baseline assessment (Visit 1/ Week 1)
|
VO2 max (ml/min/kg) concurrently measured with a medical-grade device and a smartwatch which has virutal VO2 max and physical activity parameters as assessed during treadmill exercise
|
During treadmill exercise in the day of recruitment and concurrently baseline assessment (Visit 1/ Week 1)
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Correlation between VO2 max (ml/min/kg) obtained using medical-grade device and smartwatch
Time Frame: From enrollment to end of follow up at Visit 2(Week 2)
|
VO2 max (ml/min/kg) obtained using medical-grade device and smartwatch during supervised treadmill exercise, supervised 6-minute walk test and mean and max value during other exercise
|
From enrollment to end of follow up at Visit 2(Week 2)
|
|
Correlation between SaO2 (%) obtained using medical-grade device and smartwatch
Time Frame: From enrollment to end of follow up at Visit 2(Week 2)
|
SaO2 (%) obtained using medical-grade device and smartwatch during supervised treadmill exercise, supervised 6-minute walk test and during other exercise in the follow up period.
|
From enrollment to end of follow up at Visit 2(Week 2)
|
|
SaO2 (%) measured by the smartwatch
Time Frame: From enrollment to end of follow up at Visit 2(Week 2)
|
SaO2 (%) measured by the smartwatch from enrollment to end of follow up period
|
From enrollment to end of follow up at Visit 2(Week 2)
|
|
SaO2 (%) in participants with severe disease and participants with mild disease
Time Frame: From enrollment to end of follow up at Visit 2(Week 2)
|
SaO2 (%) in participants with severe versus mild disease from enrollment to end of follow up period
|
From enrollment to end of follow up at Visit 2(Week 2)
|
|
Novel markers or patterns
Time Frame: From enrollment to end of follow up at Visit 2(Week 2)
|
Novel markers or patterns indicative of disease severity or predictive of adverse events as assessed from enrollment to end of follow up period
|
From enrollment to end of follow up at Visit 2(Week 2)
|
Collaborators and Investigators
Sponsor
Publications and helpful links
General Publications
- Wong CK, Lau YM, Lui HW, Chan WF, San WC, Zhou M, Cheng Y, Huang D, Lai WH, Lau YM, Siu CW. Automatic detection of cardiac conditions from photos of electrocardiogram captured by smartphones. Heart. 2024 Aug 14;110(17):1074-1082. doi: 10.1136/heartjnl-2023-323822.
- Guo Y, Wang H, Zhang H, Liu T, Liang Z, Xia Y, Yan L, Xing Y, Shi H, Li S, Liu Y, Liu F, Feng M, Chen Y, Lip GYH; MAFA II Investigators. Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation. J Am Coll Cardiol. 2019 Nov 12;74(19):2365-2375. doi: 10.1016/j.jacc.2019.08.019. Epub 2019 Sep 2.
- Chan PH, Wong CK, Poh YC, Pun L, Leung WW, Wong YF, Wong MM, Poh MZ, Chu DW, Siu CW. Diagnostic Performance of a Smartphone-Based Photoplethysmographic Application for Atrial Fibrillation Screening in a Primary Care Setting. J Am Heart Assoc. 2016 Jul 21;5(7):e003428. doi: 10.1161/JAHA.116.003428.
- Mannhart D, Lischer M, Knecht S, du Fay de Lavallaz J, Strebel I, Serban T, Vogeli D, Schaer B, Osswald S, Mueller C, Kuhne M, Sticherling C, Badertscher P. Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial Fibrillation: BASEL Wearable Study. JACC Clin Electrophysiol. 2023 Feb;9(2):232-242. doi: 10.1016/j.jacep.2022.09.011. Epub 2023 Jan 18.
- Perez MV, Mahaffey KW, Hedlin H, Rumsfeld JS, Garcia A, Ferris T, Balasubramanian V, Russo AM, Rajmane A, Cheung L, Hung G, Lee J, Kowey P, Talati N, Nag D, Gummidipundi SE, Beatty A, Hills MT, Desai S, Granger CB, Desai M, Turakhia MP; Apple Heart Study Investigators. Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation. N Engl J Med. 2019 Nov 14;381(20):1909-1917. doi: 10.1056/NEJMoa1901183.
- Wong CK, Un KC, Zhou M, Cheng Y, Lau YM, Shea PC, Lui HW, Zuo ML, Yin LX, Chan EW, Wong ICK, Sin SWC, Yeung PPN, Chen H, Wibowo S, Wei TLN, Lee SM, Chow A, Tong RCF, Hai J, Tam FCC, Siu CW. Daily ambulatory remote monitoring system for drug escalation in chronic heart failure with reduced ejection fraction: pilot phase of DAVID-HF study. Eur Heart J Digit Health. 2022 May 7;3(2):284-295. doi: 10.1093/ehjdh/ztac024. eCollection 2022 Jun.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
- Vascular Diseases
- Cardiovascular Diseases
- Heart Diseases
- Respiratory Tract Diseases
- Lung Diseases
- Congenital Abnormalities
- Cardiovascular Abnormalities
- Arteriosclerosis
- Arterial Occlusive Diseases
- Coronary Disease
- Myocardial Ischemia
- Hypertension
- Congenital, Hereditary, and Neonatal Diseases and Abnormalities
- Heart Failure
- Heart Defects, Congenital
- Coronary Artery Disease
- Hypertension, Pulmonary
Other Study ID Numbers
- WATCH-X
- HKU / HA HKW IRB (Other Identifier: HKU / HA HKW IRB)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Coronary Artery Disease
-
Infirmerie Protestante de LyonRecruitingCoronary Artery Bypass | Coronary Artery Disease(CAD) | Off Pump Coronary Artery Bypass Surgery | Hemodynamic Optimization | Hemodynamic Management | Off Pump Coronary Artery Bypass Graft | Coronary Artery Disease With Need for Bypass Surgery | NoradrenalineFrance
-
Shanghai Bluesail Boyuan Medical Technology Co....Not yet recruitingCoronary Artery Disease | Coronary Artery Calcification | Severe Coronary Artery DiseaseChina
-
I.R.C.C.S Ospedale Galeazzi-Sant'AmbrogioCompletedCoronary Artery Disease (CAD) | Atherosclerosis of Coronary ArteryItaly
-
Scitech Produtos Medicos SANot yet recruitingCoronary Artery Disease (CAD) | Multivessel Coronary Artery Disease | Complex Coronary Lesions | Calcific Coronary Arteriosclerosis | Small Vessel Ischemic Disease | Stenosis CoronaryBrazil
-
University Medical Centre LjubljanaRecruitingCoronary Artery Disease With Myocardial InfarctionSlovenia
-
Istanbul Mehmet Akif Ersoy Educational and Training...Bakirkoy Dr. Sadi Konuk Research and Training Hospital; Ege University; Istanbul... and other collaboratorsActive, not recruitingCoronary Artery Disease (CAD) | Coronary Bifurcation Lesion | Left Main Coronary Artery StenosisTurkey (Türkiye)
-
EBI Anti Sepsis BVCR2O B.V.Not yet recruitingCoronary Artery Disease (CAD) | Coronary Artery Bypass Graft Surgery(CABG)United States, Netherlands, Belgium, United Kingdom
-
Fundación EPICActive, not recruitingCoronary Artery Disease | Left Main Coronary Artery Disease | Left Main Coronary Artery Stenosis | Restenosis, CoronarySpain
-
Mahidol UniversityThe Princess Mantarop Kamalas Foundation, The Nurses' Association of Thailand and other collaboratorsActive, not recruitingCoronary Artery Disease (CAD) | Postoperative Recovery | Coronary Artery Bypass Graft (CABG)Thailand
-
Elixir Medical CorporationIstituto Clinico HumanitasActive, not recruitingCoronary Artery Disease | Chronic Total Occlusion of Coronary Artery | Multi Vessel Coronary Artery Disease | Bifurcation of Coronary Artery | Long Lesions Coronary Artery DiseaseItaly
Clinical Trials on Apple Watch Series 9
-
University Hospital HeidelbergThe German Heart Foundation; Klaus Tschira Stiftung, Germany; Freunde und Förderer...Completed
-
Stanford UniversityApple Inc.Terminated
-
The Cleveland ClinicCase Western Reserve UniversityCompletedHeart Rate Fast | Heart Rate LowUnited States
-
Masimo CorporationCompleted
-
Oxford University Hospitals NHS TrustCompleted
-
The Cleveland ClinicWashington University School of MedicineRecruitingAtrial FibrillationUnited States
-
Janssen Scientific Affairs, LLCApple Inc.CompletedAtrial FibrillationUnited States
-
Case Comprehensive Cancer CenterSuspendedGlioblastoma | Seizures | Venous ThromboembolismUnited States