Diastolický výkon a norepinefrin u spinálně indukované hypotenze pro porod císařským řezem (NORA-CS)
Vliv diastolického výkonu na odpověď na norepinefrin pro prevenci hypotenze vyvolané spinální anestezií při porodu císařským řezem a pohodu plodu
Background and rationale: The best agent to prevent spinal-induced hypotension is still uncertain but norepinephrine showed fewer effects on heart rate and cardiac output. In septic patients norepinephrine has been shown to produce an "endogenous fluid challenge".
Objective: We aim to assess if patients with impaired diastolic function (46% of pregnant women at term) are less able to maintain indexed cardiac output in response to norepinephrine infusion during spinal-induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.
Methods: We will assess by echocardiogram the diastolic function before surgery and will then start continuous non-invasive hemodynamic monitoring with a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) and perform a fluid challenge to relate diastolic disfunction with fluid responsiveness. Hemodynamic monitoring will continue throughout the surgery. Norepinephrine infusion will start concomitantly to beginning of spinal anesthesia and will stop 5 minutes after uterotonic medication.
Outcome: We aim to assess if patients with diastolic disfunction are less able to maintain cardiac output in response to norepinephrine infusion during spinal anesthesia induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.)
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Italy
-
Rome, Italy, Itálie, 00168
- IRCCS Fondazione Policlinico Universitario Agostino Gemelli
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
Pregnant women between the 36th and the 40th week of gestation undergoing spinal anesthesia for elective caesarian delivery.
Exclusion Criteria:
- age < 18 yo;
- preeclampsia;
- eclampsia;
- atrial fibrillation and sinus tachycardia;
- cardiovascular diseases;
- neuromuscular disease;
- emergent or urgent cesarean delivery;
- coagulopathies;
- contraindications to spinal anesthesia.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Základní věda
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: Hemodynamic Assessment
All participants underwent the same protocol-specified procedures, including a 250-mL crystalloid fluid challenge and continuous non-invasive hemodynamic monitoring using ClearSight. Standard prophylactic norepinephrine was administered during spinal anesthesia for elective cesarean delivery. Participants were categorized according to left ventricular diastolic function (normal or impaired) for subsequent physiological analyses. No allocation to different treatments was performed. |
Norepinephrine is administered as a continuous infusion at 0.05 mcg/kg/min and is kept to maintain systolic blood pressure within 90-120% of baseline during spinal anaesthesia. The infusion is started at the same time cerebrospinal fluid is obtained, immediately before injection of spinal medications, through a small-bore tubing connected directly to the peripheral intravenous catheter. It is stopped 5 minutes All patients are connected to a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) by an inflatable finger cuff placed on the midphalanx of hand middle or ring finger with no radial artery catheter and its heart reference system (HRS) is zeroed at the level of the patient's midaxillary line. The ClearSight® monitoring is started in the pre-anaesthesia room and calibrated for 5 minutes before recording. The monitoring continues throughout the procedure until patient transfer in the recovery room. All data are anonymously collected on a USB pen for statistical analysis. |
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Indexed Cardiac Output
Časové okno: Baseline/after spinal anesthesia/after delivery
|
We aim to study if the diastolic performance of the heart measured by transthoracic echocardiography in healthy pregnant women at term undergoing spinal anesthesia for caesarean delivery influences the effects of norepinephrine on indexed cardiac output (CI) measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Indexed Stroke Volume
Časové okno: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of indexed stroke volume (SVI) in ml, blood pressure (BP) in mmHg and heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Systolic Blood Pressure
Časové okno: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of blood pressure (BP) in mmHg measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Heart Rate
Časové okno: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Apgar Scores
Časové okno: Decreases of Indexed Cardiac Output after spinal anesthesia
|
We ought to correlate the reduction of neonatal Apgar Scores with decreases of indexed cardiac output measured by non-invasive continuous hemodynamic monitoring. |
Decreases of Indexed Cardiac Output after spinal anesthesia
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- 30865/19
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .