Desempenho diastólico e norepinefrina na hipotensão induzida pela coluna vertebral para cesariana (NORA-CS)
Influência do desempenho diastólico na resposta à norepinefrina para a prevenção da hipotensão induzida pela raquianestesia para cesariana e bem-estar fetal
Background and rationale: The best agent to prevent spinal-induced hypotension is still uncertain but norepinephrine showed fewer effects on heart rate and cardiac output. In septic patients norepinephrine has been shown to produce an "endogenous fluid challenge".
Objective: We aim to assess if patients with impaired diastolic function (46% of pregnant women at term) are less able to maintain indexed cardiac output in response to norepinephrine infusion during spinal-induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.
Methods: We will assess by echocardiogram the diastolic function before surgery and will then start continuous non-invasive hemodynamic monitoring with a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) and perform a fluid challenge to relate diastolic disfunction with fluid responsiveness. Hemodynamic monitoring will continue throughout the surgery. Norepinephrine infusion will start concomitantly to beginning of spinal anesthesia and will stop 5 minutes after uterotonic medication.
Outcome: We aim to assess if patients with diastolic disfunction are less able to maintain cardiac output in response to norepinephrine infusion during spinal anesthesia induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.)
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Italy
-
Rome, Italy, Itália, 00168
- IRCCS Fondazione Policlinico Universitario Agostino Gemelli
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
Pregnant women between the 36th and the 40th week of gestation undergoing spinal anesthesia for elective caesarian delivery.
Exclusion Criteria:
- age < 18 yo;
- preeclampsia;
- eclampsia;
- atrial fibrillation and sinus tachycardia;
- cardiovascular diseases;
- neuromuscular disease;
- emergent or urgent cesarean delivery;
- coagulopathies;
- contraindications to spinal anesthesia.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Ciência básica
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Experimental: Hemodynamic Assessment
All participants underwent the same protocol-specified procedures, including a 250-mL crystalloid fluid challenge and continuous non-invasive hemodynamic monitoring using ClearSight. Standard prophylactic norepinephrine was administered during spinal anesthesia for elective cesarean delivery. Participants were categorized according to left ventricular diastolic function (normal or impaired) for subsequent physiological analyses. No allocation to different treatments was performed. |
Norepinephrine is administered as a continuous infusion at 0.05 mcg/kg/min and is kept to maintain systolic blood pressure within 90-120% of baseline during spinal anaesthesia. The infusion is started at the same time cerebrospinal fluid is obtained, immediately before injection of spinal medications, through a small-bore tubing connected directly to the peripheral intravenous catheter. It is stopped 5 minutes All patients are connected to a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) by an inflatable finger cuff placed on the midphalanx of hand middle or ring finger with no radial artery catheter and its heart reference system (HRS) is zeroed at the level of the patient's midaxillary line. The ClearSight® monitoring is started in the pre-anaesthesia room and calibrated for 5 minutes before recording. The monitoring continues throughout the procedure until patient transfer in the recovery room. All data are anonymously collected on a USB pen for statistical analysis. |
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Indexed Cardiac Output
Prazo: Baseline/after spinal anesthesia/after delivery
|
We aim to study if the diastolic performance of the heart measured by transthoracic echocardiography in healthy pregnant women at term undergoing spinal anesthesia for caesarean delivery influences the effects of norepinephrine on indexed cardiac output (CI) measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Indexed Stroke Volume
Prazo: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of indexed stroke volume (SVI) in ml, blood pressure (BP) in mmHg and heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Systolic Blood Pressure
Prazo: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of blood pressure (BP) in mmHg measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Heart Rate
Prazo: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Apgar Scores
Prazo: Decreases of Indexed Cardiac Output after spinal anesthesia
|
We ought to correlate the reduction of neonatal Apgar Scores with decreases of indexed cardiac output measured by non-invasive continuous hemodynamic monitoring. |
Decreases of Indexed Cardiac Output after spinal anesthesia
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- 30865/19
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .