Optimální délka katétru v epidurálním prostoru pro porodní analgezii u neobézních žen: Randomizovaná kontrolovaná studie 4 cm versus 5 cm
Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.
Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.
Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.
This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.
Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.
The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Ontario
-
Toronto, Ontario, Kanada, M5G1X5
- Mount Sinai Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- All women aged 18 years and above.
- 3-7 cm dilation at time of insertion.
- Women with BMI < 40 kg/m2
Exclusion Criteria:
- Known contraindication to epidural insertion.
- Inability or unwillingness to provide written consent.
- Previous difficult epidural insertion.
- Previous failed epidural.
- Imminent instrumental or operative delivery.
- Dural puncture.
- Combined spinal epidural analgesia.
- High BMI > 40 kg/m2
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Trojnásobný
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Aktivní komparátor: 4 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 4 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Ostatní jména:
|
|
Aktivní komparátor: 5 cm epidural catheter
The epidural catheter will be thread into the epidural space at a length of 5 cm. |
The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Composite outcome
Časové okno: 24 hours
|
Presence of any of the individual primary outcomes described below:
|
24 hours
|
|
Sensory block level < T10
Časové okno: 1 hour
|
Sensory block level to ice will be measured 1 hour after the loading dose is administered. Yes: inadequate block No: adequate block |
1 hour
|
|
Block height discrepancy
Časové okno: 24 hours
|
Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery. Yes: inadequate block No: adequate block |
24 hours
|
|
Re-siting of the epidural
Časové okno: 24 hours
|
Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:
|
24 hours
|
|
Adjustment of catheter length
Časové okno: 24 hours
|
Adjustment of catheter length at any time during labour would also indicate an inadequate block. |
24 hours
|
|
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
Časové okno: 24 hours
|
The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist. |
24 hours
|
|
Pain score >3 at any time during labour: questionnaire
Časové okno: 24 hours
|
A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Number of epidural top-ups administered by the nursing team
Časové okno: 24 hours
|
The number of times the labour and delivery nurse has to administer a top-up of the epidural. |
24 hours
|
|
Number of epidural top-ups administered by the anesthesiologist
Časové okno: 24 hours
|
The number of times the anesthesiologist has to administer a top-up of the epidural. |
24 hours
|
|
Pain scores recorded throughout labour: questionnaire
Časové okno: 24 hours
|
A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever. |
24 hours
|
|
Hourly sensory block height assessment
Časové okno: 24 hours
|
Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice. |
24 hours
|
|
Incidence of intravascular epidural placement
Časové okno: 24 hours
|
Any incidence of intravascular epidural placement during labour will be recorded. |
24 hours
|
|
Incidence of catheter dislodgement
Časové okno: 24 hours
|
Any incidence of catheter dislodgement during labour will be recorded. |
24 hours
|
|
Motor block using Bromage scale
Časové okno: 24 hours
|
Bromage scale will be recorded hourly as standard practice.
|
24 hours
|
|
Presence of paresthesia on insertion.
Časové okno: 1 hour
|
Any presence of paresthesia on insertion will be recorded. |
1 hour
|
|
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
Časové okno: 24 hours
|
Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist. |
24 hours
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- 21-06
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .