Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Optimální délka katétru v epidurálním prostoru pro porodní analgezii u neobézních žen: Randomizovaná kontrolovaná studie 4 cm versus 5 cm

Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.

Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.

Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.

This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.

Přehled studie

Postavení

Dokončeno

Podmínky

Intervence / Léčba

Detailní popis

Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.

Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.

The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.

Typ studie

Intervenční

Zápis (Aktuální)

200

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Ontario
      • Toronto, Ontario, Kanada, M5G1X5
        • Mount Sinai Hospital

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let až 50 let (Dospělý)

Přijímá zdravé dobrovolníky

Ano

Pohlaví způsobilá ke studiu

Ženský

Popis

Inclusion Criteria:

  • All women aged 18 years and above.
  • 3-7 cm dilation at time of insertion.
  • Women with BMI < 40 kg/m2

Exclusion Criteria:

  • Known contraindication to epidural insertion.
  • Inability or unwillingness to provide written consent.
  • Previous difficult epidural insertion.
  • Previous failed epidural.
  • Imminent instrumental or operative delivery.
  • Dural puncture.
  • Combined spinal epidural analgesia.
  • High BMI > 40 kg/m2

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Trojnásobný

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Aktivní komparátor: 4 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 4 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

Ostatní jména:
  • epidurální
Aktivní komparátor: 5 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 5 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

Ostatní jména:
  • epidurální

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Composite outcome
Časové okno: 24 hours

Presence of any of the individual primary outcomes described below:

  • Sensory block level <T10
  • VRNS pain score >3
  • Block height dicrepancy (unilateral or asymmetric block)
  • Re-siting of the epidural
  • Adjustment of catheter length
  • Abandonment of epidural or substitute for alternative method of analgesia
24 hours
Sensory block level < T10
Časové okno: 1 hour

Sensory block level to ice will be measured 1 hour after the loading dose is administered.

Yes: inadequate block No: adequate block

1 hour
Block height discrepancy
Časové okno: 24 hours

Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery.

Yes: inadequate block No: adequate block

24 hours
Re-siting of the epidural
Časové okno: 24 hours

Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:

  • Inadequate analgesia
  • Persistent unilateral block
  • Persistent intravascular placement
  • Extensive motor block
  • Hypotension
  • High block
24 hours
Adjustment of catheter length
Časové okno: 24 hours

Adjustment of catheter length at any time during labour would also indicate an inadequate block.

24 hours
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
Časové okno: 24 hours

The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist.

24 hours
Pain score >3 at any time during labour: questionnaire
Časové okno: 24 hours

A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Number of epidural top-ups administered by the nursing team
Časové okno: 24 hours

The number of times the labour and delivery nurse has to administer a top-up of the epidural.

24 hours
Number of epidural top-ups administered by the anesthesiologist
Časové okno: 24 hours

The number of times the anesthesiologist has to administer a top-up of the epidural.

24 hours
Pain scores recorded throughout labour: questionnaire
Časové okno: 24 hours

A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours
Hourly sensory block height assessment
Časové okno: 24 hours

Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice.

24 hours
Incidence of intravascular epidural placement
Časové okno: 24 hours

Any incidence of intravascular epidural placement during labour will be recorded.

24 hours
Incidence of catheter dislodgement
Časové okno: 24 hours

Any incidence of catheter dislodgement during labour will be recorded.

24 hours
Motor block using Bromage scale
Časové okno: 24 hours

Bromage scale will be recorded hourly as standard practice.

  • 3: Unable to move feet or knees
  • 2: Able to move feet only
  • 1: Able to just move knees
  • 0: Full flexion of knees and feet
24 hours
Presence of paresthesia on insertion.
Časové okno: 1 hour

Any presence of paresthesia on insertion will be recorded.

1 hour
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
Časové okno: 24 hours

Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist.

24 hours

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

23. listopadu 2021

Primární dokončení (Aktuální)

26. července 2024

Dokončení studie (Aktuální)

27. července 2024

Termíny zápisu do studia

První předloženo

25. června 2021

První předloženo, které splnilo kritéria kontroly kvality

25. června 2021

První zveřejněno (Aktuální)

30. června 2021

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

17. listopadu 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

12. listopadu 2026

Naposledy ověřeno

1. března 2025

Více informací

Termíny související s touto studií

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit