Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Optimal længde af kateter i det epidurale rum til analgesi ved fødsel hos ikke-overvægtige kvinder: et randomiseret kontrolleret forsøg på 4 cm versus 5 cm

Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.

Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.

Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.

This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.

Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.

The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

200

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Ontario
      • Toronto, Ontario, Canada, M5G1X5
        • Mount Sinai Hospital

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 50 år (Voksen)

Tager imod sunde frivillige

Ja

Køn, der er berettiget til at studere

Kvinde

Beskrivelse

Inclusion Criteria:

  • All women aged 18 years and above.
  • 3-7 cm dilation at time of insertion.
  • Women with BMI < 40 kg/m2

Exclusion Criteria:

  • Known contraindication to epidural insertion.
  • Inability or unwillingness to provide written consent.
  • Previous difficult epidural insertion.
  • Previous failed epidural.
  • Imminent instrumental or operative delivery.
  • Dural puncture.
  • Combined spinal epidural analgesia.
  • High BMI > 40 kg/m2

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Tredobbelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: 4 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 4 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

Andre navne:
  • epidural
Aktiv komparator: 5 cm epidural catheter

The epidural catheter will be thread into the epidural space at a length of 5 cm.

The epidural catheter length will vary, either 4 cm or 5 cm into the epidural space.

Andre navne:
  • epidural

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Composite outcome
Tidsramme: 24 hours

Presence of any of the individual primary outcomes described below:

  • Sensory block level <T10
  • VRNS pain score >3
  • Block height dicrepancy (unilateral or asymmetric block)
  • Re-siting of the epidural
  • Adjustment of catheter length
  • Abandonment of epidural or substitute for alternative method of analgesia
24 hours
Sensory block level < T10
Tidsramme: 1 hour

Sensory block level to ice will be measured 1 hour after the loading dose is administered.

Yes: inadequate block No: adequate block

1 hour
Block height discrepancy
Tidsramme: 24 hours

Unilateral block or block height discrepancy of >3 dermatomal levels at any time prior to delivery.

Yes: inadequate block No: adequate block

24 hours
Re-siting of the epidural
Tidsramme: 24 hours

Re-siting of the epidural at any time during labour will indicate an inadequate block, for any of the following reasons:

  • Inadequate analgesia
  • Persistent unilateral block
  • Persistent intravascular placement
  • Extensive motor block
  • Hypotension
  • High block
24 hours
Adjustment of catheter length
Tidsramme: 24 hours

Adjustment of catheter length at any time during labour would also indicate an inadequate block.

24 hours
Abandonment of epidural or substitute for alternative method of analgesia after initial failure: questionnaire
Tidsramme: 24 hours

The epidural analgesia will also be considered inadequate if the procedure is abandoned or another method of analgesia is used. This will be recorded by the anesthesiologist.

24 hours
Pain score >3 at any time during labour: questionnaire
Tidsramme: 24 hours

A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Number of epidural top-ups administered by the nursing team
Tidsramme: 24 hours

The number of times the labour and delivery nurse has to administer a top-up of the epidural.

24 hours
Number of epidural top-ups administered by the anesthesiologist
Tidsramme: 24 hours

The number of times the anesthesiologist has to administer a top-up of the epidural.

24 hours
Pain scores recorded throughout labour: questionnaire
Tidsramme: 24 hours

A verbal numerical rating score (VNRS), where 0=no pain and 10=worst pain ever. A verbal numerical rating score (VNRS) greater than 3, where 0=no pain and 10=worst pain ever.

24 hours
Hourly sensory block height assessment
Tidsramme: 24 hours

Hourly sensory block height assessment, using sensation to ice. This is recorded hourly as standard practice.

24 hours
Incidence of intravascular epidural placement
Tidsramme: 24 hours

Any incidence of intravascular epidural placement during labour will be recorded.

24 hours
Incidence of catheter dislodgement
Tidsramme: 24 hours

Any incidence of catheter dislodgement during labour will be recorded.

24 hours
Motor block using Bromage scale
Tidsramme: 24 hours

Bromage scale will be recorded hourly as standard practice.

  • 3: Unable to move feet or knees
  • 2: Able to move feet only
  • 1: Able to just move knees
  • 0: Full flexion of knees and feet
24 hours
Presence of paresthesia on insertion.
Tidsramme: 1 hour

Any presence of paresthesia on insertion will be recorded.

1 hour
Adequacy of conversion to surgical block if required for cesarean delivery: questionnaire
Tidsramme: 24 hours

Adequacy of conversion to surgical block in cases requiring cesarean deliveries for failed labor or fetal issues. This will be recorded by the anesthesiologist.

24 hours

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Efterforskere

  • Ledende efterforsker: Mrinalini Balki, MD, MOUNT SINAI HOSPITAL

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

23. november 2021

Primær færdiggørelse (Faktiske)

26. juli 2024

Studieafslutning (Faktiske)

27. juli 2024

Datoer for studieregistrering

Først indsendt

25. juni 2021

Først indsendt, der opfyldte QC-kriterier

25. juni 2021

Først opslået (Faktiske)

30. juni 2021

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

17. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

12. november 2026

Sidst verificeret

1. marts 2025

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • 21-06

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .