Zkouška designu objektivu Euclid Phoenix 2
Zkušební zkouška designu objektivu Euclid Phoenix, část 2
Lens wettability and subjective comfort of Euclid orthokeratology lenses with and without an enhanced coating will be compared in 50 children. Axial elongation will be monitored in pediatric patients who qualify and consent.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
This clinical investigation is a prospective, randomized, double-masked, two-arm non-crossover trial. Existing Euclid orthokeratology wearers are randomized to be fit in lenses either with the standard lens coating or with the enhanced lens coating containing MPC. Subjects are evaluated at Dispense (Day 0), 1-Day, 2-Week, 1-Month, and 3-Months. Participants under the age of 17 are presented with the option to participate in an optional 9-month study extension, over which axial length is monitored.
The primary objective of this trial is to provide an assessment of the lens wettability and patient comfort with an enhanced surface treatment for the Emerald Lens design when used by practitioners with moderate experience with fitting Euclid orthokeratology lenses.
The hypothesis to be tested is that the proportion of participants with a lens wettability score of > 3 (on a 5 point scale) with the enhanced surface treatment will be greater than that of the current lens surface, using a 1 to 5 scale
The primary outcome variable is lens wettability as measured on eye using a 1 to 5 scale
This clinical investigation will be a prospective, randomized, double-masked two-arm non-crossover trial.
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Minnesota
-
Edina, Minnesota, Spojené státy, 55436
- Cornea and Contact Lens Institute of Minnesota
-
Sartell, Minnesota, Spojené státy, 56377
- Pinecone Vision Center
-
-
New Jersey
-
North Brunswick, New Jersey, Spojené státy, 08902
- Somerset Eye Care
-
-
Tennessee
-
Memphis, Tennessee, Spojené státy, 38104
- Southern College of Optometry
-
-
Washington
-
Kirkland, Washington, Spojené státy, 98034
- Specialty Eyecare Group
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
-
Be of legal age or, if under legal age have written consent of their parent or guardian to participate.
-
Sign written Informed Consent (and the California Bill of Rights, if applicable).
-
Ages 6-35 (inclusive) and able to understand and assent to participation
-
Current wearers of Euclid Emerald (Oprifocon A) Orthokeratology lenses, which at initiation of fitting, had
- Need of optical correction for myopia, from -1.00 to -5.00 Diopters (D).
- Refractive astigmatism of less than -1.50 D.
-
Have a minimum Best Spectacle Corrected Visual Acuity (BSCVA) of 20/40 or better in each eye.
-
Have acceptable or optimal fit with study lenses (once fitting has been completed) and be willing to wear these lenses as directed for the duration of the study.
-
On examination, have ocular findings considered to be within normal limits, including:
- No evidence of active infection involving the conjunctiva, lids or adnexa.
- No evidence of structural abnormalities of the lid, conjunctiva or adnexal tissue considered significant by the investigator to include minimum levels (Grade 2 or less) of tarsal-conjunctival abnormalities
- Clear corneas with no evidence of edema, staining, opacities, corneal neovascularization greater than a trace amount (i.e. All vessels extending less than 1.5 mm from the limbus); all as observed on slit lamp examination.
- No iritis.
- No herpes keratitis (recurrent or otherwise) or other active ocular disease that would contraindicate lens wear or lessen attainability of VA sought in this study (20/40 or better).
- No evidence of dry eye or meibomian gland dysfunction
-
Normal binocularity (no amblyopia or strabismus, and no anisometropia of greater than 2.00D)
-
Be willing and able to follow instructions and attend the schedule of follow-up visits.
Exclusion Criteria:
- Does not meet the any of the above inclusion criteria
- Not able or willing to provide informed consent and assent
- Requires concurrent ocular medication
- Eye injury or surgery within twelve weeks immediately prior to enrollment
- Pre-existing ocular condition that would preclude contact lens fitting
- Currently enrolled in an ophthalmic clinical trial
- Pregnant or lactating or expect to become pregnant during the trial
- Evidence of systemic or ocular abnormality, infection or disease likely to affect successful wear of contact lenses or use of their accessory solutions.
- Allergy or sensitivity to any product used in this trial
- Any systemic disease including autoimmune disease, immunocompromising diseases, connective tissue disease, clinically significant atopic diseases, insulin dependent diabetes, use of medications including corticosteroids and antimetabolites that may affect the eye or be exaggerated by contact lenses.
- Strabismus/amblyopia
- Habitual uncorrected anisometropia ≥ 2.00D
- Subjects who have undergone corneal refractive surgery
- Subjects with severe corneal irregularity contraindicating lens wear
- Inability to wear contact lenses, or an unacceptable contact lens fit
- Poor or unacceptable fit with any study lens
- Employees, staff or family members of personnel at the site
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Čtyřnásobek
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: Euclid orthokeartology (standard coating)
Euclid Orthokeratology Contact Lenses are lathe cut contact lenses with spherical posterior surfaces. The posterior curve is selected to properly fit an individual eye for orthokeratology and the anterior curve is selected to provide the necessary optical power for a temporary reduction of myopia. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea. |
Lens with the current coating |
|
Experimentální: Euclid orthokeartology (enhanced coating)
Euclid Orthokeratology Contact Lenses are lathe cut contact lenses with spherical posterior surfaces. The posterior curve is selected to properly fit an individual eye for orthokeratology and the anterior curve is selected to provide the necessary optical power for a temporary reduction of myopia. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea. |
Lens with the enhanced coating |
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Lens wettability
Časové okno: 12 months
|
Lens wettability as measured on eye using a 1 to 5 scale (5 better) |
12 months
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Patient comfort ratings
Časové okno: 12 months
|
Patient comfort as measured by patient reported outcome using a 1 to 5 scale (5 better) |
12 months
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- EU-PHX-RCT-002
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .