Euclid Phoenix Lens Design Trial 2
Euclid Phoenix Lens Design Trial Del 2
Lens wettability and subjective comfort of Euclid orthokeratology lenses with and without an enhanced coating will be compared in 50 children. Axial elongation will be monitored in pediatric patients who qualify and consent.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
This clinical investigation is a prospective, randomized, double-masked, two-arm non-crossover trial. Existing Euclid orthokeratology wearers are randomized to be fit in lenses either with the standard lens coating or with the enhanced lens coating containing MPC. Subjects are evaluated at Dispense (Day 0), 1-Day, 2-Week, 1-Month, and 3-Months. Participants under the age of 17 are presented with the option to participate in an optional 9-month study extension, over which axial length is monitored.
The primary objective of this trial is to provide an assessment of the lens wettability and patient comfort with an enhanced surface treatment for the Emerald Lens design when used by practitioners with moderate experience with fitting Euclid orthokeratology lenses.
The hypothesis to be tested is that the proportion of participants with a lens wettability score of > 3 (on a 5 point scale) with the enhanced surface treatment will be greater than that of the current lens surface, using a 1 to 5 scale
The primary outcome variable is lens wettability as measured on eye using a 1 to 5 scale
This clinical investigation will be a prospective, randomized, double-masked two-arm non-crossover trial.
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Minnesota
-
Edina, Minnesota, Forenede Stater, 55436
- Cornea and Contact Lens Institute of Minnesota
-
Sartell, Minnesota, Forenede Stater, 56377
- Pinecone Vision Center
-
-
New Jersey
-
North Brunswick, New Jersey, Forenede Stater, 08902
- Somerset Eye Care
-
-
Tennessee
-
Memphis, Tennessee, Forenede Stater, 38104
- Southern College of Optometry
-
-
Washington
-
Kirkland, Washington, Forenede Stater, 98034
- Specialty Eyecare Group
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
-
Be of legal age or, if under legal age have written consent of their parent or guardian to participate.
-
Sign written Informed Consent (and the California Bill of Rights, if applicable).
-
Ages 6-35 (inclusive) and able to understand and assent to participation
-
Current wearers of Euclid Emerald (Oprifocon A) Orthokeratology lenses, which at initiation of fitting, had
- Need of optical correction for myopia, from -1.00 to -5.00 Diopters (D).
- Refractive astigmatism of less than -1.50 D.
-
Have a minimum Best Spectacle Corrected Visual Acuity (BSCVA) of 20/40 or better in each eye.
-
Have acceptable or optimal fit with study lenses (once fitting has been completed) and be willing to wear these lenses as directed for the duration of the study.
-
On examination, have ocular findings considered to be within normal limits, including:
- No evidence of active infection involving the conjunctiva, lids or adnexa.
- No evidence of structural abnormalities of the lid, conjunctiva or adnexal tissue considered significant by the investigator to include minimum levels (Grade 2 or less) of tarsal-conjunctival abnormalities
- Clear corneas with no evidence of edema, staining, opacities, corneal neovascularization greater than a trace amount (i.e. All vessels extending less than 1.5 mm from the limbus); all as observed on slit lamp examination.
- No iritis.
- No herpes keratitis (recurrent or otherwise) or other active ocular disease that would contraindicate lens wear or lessen attainability of VA sought in this study (20/40 or better).
- No evidence of dry eye or meibomian gland dysfunction
-
Normal binocularity (no amblyopia or strabismus, and no anisometropia of greater than 2.00D)
-
Be willing and able to follow instructions and attend the schedule of follow-up visits.
Exclusion Criteria:
- Does not meet the any of the above inclusion criteria
- Not able or willing to provide informed consent and assent
- Requires concurrent ocular medication
- Eye injury or surgery within twelve weeks immediately prior to enrollment
- Pre-existing ocular condition that would preclude contact lens fitting
- Currently enrolled in an ophthalmic clinical trial
- Pregnant or lactating or expect to become pregnant during the trial
- Evidence of systemic or ocular abnormality, infection or disease likely to affect successful wear of contact lenses or use of their accessory solutions.
- Allergy or sensitivity to any product used in this trial
- Any systemic disease including autoimmune disease, immunocompromising diseases, connective tissue disease, clinically significant atopic diseases, insulin dependent diabetes, use of medications including corticosteroids and antimetabolites that may affect the eye or be exaggerated by contact lenses.
- Strabismus/amblyopia
- Habitual uncorrected anisometropia ≥ 2.00D
- Subjects who have undergone corneal refractive surgery
- Subjects with severe corneal irregularity contraindicating lens wear
- Inability to wear contact lenses, or an unacceptable contact lens fit
- Poor or unacceptable fit with any study lens
- Employees, staff or family members of personnel at the site
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Firedobbelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: Euclid orthokeartology (standard coating)
Euclid Orthokeratology Contact Lenses are lathe cut contact lenses with spherical posterior surfaces. The posterior curve is selected to properly fit an individual eye for orthokeratology and the anterior curve is selected to provide the necessary optical power for a temporary reduction of myopia. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea. |
Lens with the current coating |
|
Eksperimentel: Euclid orthokeartology (enhanced coating)
Euclid Orthokeratology Contact Lenses are lathe cut contact lenses with spherical posterior surfaces. The posterior curve is selected to properly fit an individual eye for orthokeratology and the anterior curve is selected to provide the necessary optical power for a temporary reduction of myopia. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea. |
Lens with the enhanced coating |
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Lens wettability
Tidsramme: 12 months
|
Lens wettability as measured on eye using a 1 to 5 scale (5 better) |
12 months
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Patient comfort ratings
Tidsramme: 12 months
|
Patient comfort as measured by patient reported outcome using a 1 to 5 scale (5 better) |
12 months
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- EU-PHX-RCT-002
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .