Safety and Efficacy of Neuroform3TM for Intracranial Aneurysm Treatment (SENAT)
This is a prospective observational multicenter registry to evaluate safety and efficacy data on Neuroform3TM stenting for treatment with endovascular coiling of wide neck aneurysms on an intent to treat basis.
The objectives of this study are:
- Assessment of morbidity-mortality at 1 month and 12-18 months following the treatment of the intracranial aneurysm with Neuroform3TM stent and endovascular coiling using the modified Rankin scale (mRS).
- to evaluate adverse events.
- Angiographic assessment at 12-18 months compared to the initial post-treatment assessment via the modified Raymond scale and same/better/worse scale.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Kontakter og lokationer
Studiesteder
-
-
-
Bordeaux, Frankrig, 33076
- Centre Hospitalier pellegrin
-
Caen, Frankrig, 14033
- CHU Hôpital de la Côte de Nacre
-
Lille, Frankrig, 59037
- CHRU Salengro
-
Limoges, Frankrig, 87042
- CHU Limoges
-
Lyon, Frankrig, 69394
- Hôpital neurologique
-
Montpellier, Frankrig, 34059
- Hôpital Gui de Chauliac
-
Nancy, Frankrig, 54035
- CHU Nancy
-
Nantes, Frankrig, 44035
- CHU Hôpital Guillaume et René Laënnec
-
Nice, Frankrig, 06000
- Hôpital Saint-Roch
-
Paris, Frankrig, 75010
- Hôpital Lariboisiere
-
Paris, Frankrig, 75013
- Groupe Hospitalier Pitie-Salpetriere
-
Paris, Frankrig, 75019
- Fondation Rotschild
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
Inclusion Criteria:
- 18 year's old patient or above.
- every patient suffering from an un-ruptured or ruptured aneurysm, for whom the endovascular treatment approach using the Neuroform3TM stent is considered by the therapeutic team in charge.
- patient who has given his consent to participate to the study and to get his anonymized data collected
Exclusion Criteria:
- patient with dissecting or fusiform aneurysm
- treatment of several aneurysms in the same procedure, except adjacent aneurysm treated by the same stent
- severe vasospasm
- aneurysm associated with an arterio-venous malformation
- use of another Neuroform3TM stent
- woman pregnant or nursing
- patients not likely to be followed upon (living abroad)
- people protected by justice (safeguard of law, supervision or trusteeship)
- patient unsuitable to the anti-thrombotic and/or to anticoagulants therapies
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Morbidity and Mortality associated with stenting and coiling
Tidsramme: 30 days and 12-18 months post procedure
|
Assessment of morbidity and mortality at 30 days and 12-18 months post endovascular treatment of wide neck aneurysm with a Neurform 3 stent and coiling as assessed by the modified Rankin scale (mRS).
|
30 days and 12-18 months post procedure
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Efficacy of the Neuroform stent for treatment of wide neck aneurysms
Tidsramme: post procedure and at 12-18 months post procedure
|
Assessment of the morphological results post endovascular coiling and stenting of wide neck aneurysms and assessment of anatomical stability of the treatment at 12-18 months post procedure
|
post procedure and at 12-18 months post procedure
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Efterforskere
Efterforskere
- Ledende efterforsker: Alessandra Biondi
- Ledende efterforsker: Alain Bonafé
Publikationer og nyttige links
Generelle publikationer
- Murayama Y, Nien YL, Duckwiler G, Gobin YP, Jahan R, Frazee J, Martin N, Vinuela F. Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience. J Neurosurg. 2003 May;98(5):959-66. doi: 10.3171/jns.2003.98.5.0959.
- Leung CH, Poon WS, Yu LM; International Subarachnoid Aneurysm Trial. The ISAT trial. Lancet. 2003 Feb 1;361(9355):430-1; author reply 432. doi: 10.1016/s0140-6736(03)12405-1. No abstract available.
- Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME. Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol. 2005 May;26(5):1223-31.
- Alfke K, Straube T, Dorner L, Mehdorn HM, Jansen O. Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization. AJNR Am J Neuroradiol. 2004 Apr;25(4):584-91.
- Barath K, Cassot F, Rufenacht DA, Fasel JH. Anatomically shaped internal carotid artery aneurysm in vitro model for flow analysis to evaluate stent effect. AJNR Am J Neuroradiol. 2004 Nov-Dec;25(10):1750-9.
- Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH. Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery. 2004 Jun;54(6):1359-67; discussion 1368. doi: 10.1227/01.neu.0000124484.87635.cd.
- Byrne JV, Bashiri M, Pasco A, Morris JH. A novel flexible endovascular stent for use in small and tortuous vessels. Neuroradiology. 2000 Jan;42(1):56-61. doi: 10.1007/s002340050015.
- Canton G, Levy DI, Lasheras JC, Nelson PK. Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms. J Neurosurg. 2005 Nov;103(5):891-902. doi: 10.3171/jns.2005.103.5.0891.
- dos Santos Souza MP, Agid R, Willinsky RA, Cusimano M, Montanera W, Wallace MC, terBrugge KG, Marotta TR. Microstent-assisted coiling for wide-necked intracranial aneurysms. Can J Neurol Sci. 2005 Feb;32(1):71-81. doi: 10.1017/s0317167100016917.
- Fiorella D, Albuquerque FC, Han P, McDougall CG. Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery. 2004 Jan;54(1):6-16; discussion 16-7. doi: 10.1227/01.neu.0000097194.35781.ea.
- Howington JU, Hanel RA, Harrigan MR, Levy EI, Guterman LR, Hopkins LN. The Neuroform stent, the first microcatheter-delivered stent for use in the intracranial circulation. Neurosurgery. 2004 Jan;54(1):2-5. doi: 10.1227/01.neu.0000099370.05758.4d. No abstract available.
- Lylyk P, Ferrario A, Pasbon B, Miranda C, Doroszuk G. Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. J Neurosurg. 2005 Feb;102(2):235-41. doi: 10.3171/jns.2005.102.2.0235.
- Wakhloo AK, Lanzino G, Lieber BB, Hopkins LN. Stents for intracranial aneurysms: the beginning of a new endovascular era? Neurosurgery. 1998 Aug;43(2):377-9. doi: 10.1097/00006123-199808000-00126. No abstract available.
Datoer for undersøgelser
Studer store datoer
Studiestart
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- SENAT
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .