Safety and Efficacy of Neuroform3TM for Intracranial Aneurysm Treatment (SENAT)
This is a prospective observational multicenter registry to evaluate safety and efficacy data on Neuroform3TM stenting for treatment with endovascular coiling of wide neck aneurysms on an intent to treat basis.
The objectives of this study are:
- Assessment of morbidity-mortality at 1 month and 12-18 months following the treatment of the intracranial aneurysm with Neuroform3TM stent and endovascular coiling using the modified Rankin scale (mRS).
- to evaluate adverse events.
- Angiographic assessment at 12-18 months compared to the initial post-treatment assessment via the modified Raymond scale and same/better/worse scale.
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
-
Bordeaux, França, 33076
- Centre Hospitalier pellegrin
-
Caen, França, 14033
- CHU Hôpital de la Côte de Nacre
-
Lille, França, 59037
- CHRU Salengro
-
Limoges, França, 87042
- CHU Limoges
-
Lyon, França, 69394
- Hôpital neurologique
-
Montpellier, França, 34059
- Hôpital Gui de Chauliac
-
Nancy, França, 54035
- CHU Nancy
-
Nantes, França, 44035
- CHU Hôpital Guillaume et René Laënnec
-
Nice, França, 06000
- Hôpital Saint-Roch
-
Paris, França, 75010
- Hôpital Lariboisière
-
Paris, França, 75013
- Groupe Hospitalier Pitie-Salpetriere
-
Paris, França, 75019
- Fondation Rotschild
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- 18 year's old patient or above.
- every patient suffering from an un-ruptured or ruptured aneurysm, for whom the endovascular treatment approach using the Neuroform3TM stent is considered by the therapeutic team in charge.
- patient who has given his consent to participate to the study and to get his anonymized data collected
Exclusion Criteria:
- patient with dissecting or fusiform aneurysm
- treatment of several aneurysms in the same procedure, except adjacent aneurysm treated by the same stent
- severe vasospasm
- aneurysm associated with an arterio-venous malformation
- use of another Neuroform3TM stent
- woman pregnant or nursing
- patients not likely to be followed upon (living abroad)
- people protected by justice (safeguard of law, supervision or trusteeship)
- patient unsuitable to the anti-thrombotic and/or to anticoagulants therapies
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Morbidity and Mortality associated with stenting and coiling
Prazo: 30 days and 12-18 months post procedure
|
Assessment of morbidity and mortality at 30 days and 12-18 months post endovascular treatment of wide neck aneurysm with a Neurform 3 stent and coiling as assessed by the modified Rankin scale (mRS).
|
30 days and 12-18 months post procedure
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Efficacy of the Neuroform stent for treatment of wide neck aneurysms
Prazo: post procedure and at 12-18 months post procedure
|
Assessment of the morphological results post endovascular coiling and stenting of wide neck aneurysms and assessment of anatomical stability of the treatment at 12-18 months post procedure
|
post procedure and at 12-18 months post procedure
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Alessandra Biondi
- Investigador principal: Alain Bonafé
Publicações e links úteis
Publicações Gerais
- Murayama Y, Nien YL, Duckwiler G, Gobin YP, Jahan R, Frazee J, Martin N, Vinuela F. Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience. J Neurosurg. 2003 May;98(5):959-66. doi: 10.3171/jns.2003.98.5.0959.
- Leung CH, Poon WS, Yu LM; International Subarachnoid Aneurysm Trial. The ISAT trial. Lancet. 2003 Feb 1;361(9355):430-1; author reply 432. doi: 10.1016/s0140-6736(03)12405-1. No abstract available.
- Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME. Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol. 2005 May;26(5):1223-31.
- Alfke K, Straube T, Dorner L, Mehdorn HM, Jansen O. Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization. AJNR Am J Neuroradiol. 2004 Apr;25(4):584-91.
- Barath K, Cassot F, Rufenacht DA, Fasel JH. Anatomically shaped internal carotid artery aneurysm in vitro model for flow analysis to evaluate stent effect. AJNR Am J Neuroradiol. 2004 Nov-Dec;25(10):1750-9.
- Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH. Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery. 2004 Jun;54(6):1359-67; discussion 1368. doi: 10.1227/01.neu.0000124484.87635.cd.
- Byrne JV, Bashiri M, Pasco A, Morris JH. A novel flexible endovascular stent for use in small and tortuous vessels. Neuroradiology. 2000 Jan;42(1):56-61. doi: 10.1007/s002340050015.
- Canton G, Levy DI, Lasheras JC, Nelson PK. Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms. J Neurosurg. 2005 Nov;103(5):891-902. doi: 10.3171/jns.2005.103.5.0891.
- dos Santos Souza MP, Agid R, Willinsky RA, Cusimano M, Montanera W, Wallace MC, terBrugge KG, Marotta TR. Microstent-assisted coiling for wide-necked intracranial aneurysms. Can J Neurol Sci. 2005 Feb;32(1):71-81. doi: 10.1017/s0317167100016917.
- Fiorella D, Albuquerque FC, Han P, McDougall CG. Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery. 2004 Jan;54(1):6-16; discussion 16-7. doi: 10.1227/01.neu.0000097194.35781.ea.
- Howington JU, Hanel RA, Harrigan MR, Levy EI, Guterman LR, Hopkins LN. The Neuroform stent, the first microcatheter-delivered stent for use in the intracranial circulation. Neurosurgery. 2004 Jan;54(1):2-5. doi: 10.1227/01.neu.0000099370.05758.4d. No abstract available.
- Lylyk P, Ferrario A, Pasbon B, Miranda C, Doroszuk G. Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. J Neurosurg. 2005 Feb;102(2):235-41. doi: 10.3171/jns.2005.102.2.0235.
- Wakhloo AK, Lanzino G, Lieber BB, Hopkins LN. Stents for intracranial aneurysms: the beginning of a new endovascular era? Neurosurgery. 1998 Aug;43(2):377-9. doi: 10.1097/00006123-199808000-00126. No abstract available.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- SENAT
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .