Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Indledende korrektion Keratokonus

9. november 2026 opdateret af: University of Illinois Chicago

Indledende korrektion Keratokonus: Skleral vs hornhindegasgennemtrængelige linser SCOPE-undersøgelse

Keratoconus is a non-inflammatory, progressive disease in which corneal irregularity increases. As the condition develops, more advanced forms of optical correction are needed to improve vision for patients. Until recently, small diameter corneal gas permeable lenses were considered the primary mode of correction for patients with keratoconus. Now, however, practitioners have multiple options for reducing the optical aberrations caused by keratoconus, including scleral lenses. As of yet, no single option for optical correction has been identified as the preferred mode of correction in terms of overall patient satisfaction with vision, comfort, and ease of use. The order in which various forms of optical correction would be most logically introduced has yet to be determined. This is a study comparing small diameter corneal gas permeable and large diameter scleral lenses in individuals with keratoconus.

This study will prospectively compare visual satisfaction and ease of use between corneal gas permeable and scleral lenses for patients with mild to moderate keratoconus.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

While both corneal gas permeable and scleral lenses have been show to improve visual acuity in individuals with keratoconus, it has yet to be determined if one option has superior comfort and overall patient satisfaction in patients new to gas permeable lens use. In this study, patients will be prospectively fit with both corneal gas permeable and scleral lenses according to standard clinical practice. Both corneal gas permeable and scleral lenses are considered standard of care for patients with keratoconus.

The investigators hypothesize that study participants will select scleral lens over corneal gas permeable lens as their preferred final lens type of choice.

The Primary outcome measure of this study is participant selected final lens choice for continued use for the management of keratoconus.

Methods:

Study Design This is a prospective, multi-center, randomized interventional clinical trial with a 2x2 crossover design of patients with keratoconus fit with corneal and scleral gas permeable contact lenses. The crossover design allows intra-subject differences between two randomized groups with participants serving as their own controls. Contact lens #1 will be the SynergEyes VS (Synergeyes, Inc., Carlsbad CA) which features bi-tangential toric peripheries with linear landing zones. The standard lens is 16.0mm and is available from 14.5 to 17.5mm diameters. Contact lens #2 will be the RoseK2 corneal gas permeable lens (Blanchard Contact Lens, Inc. Manchester, NH). The lens is available in with a base curve range from 4.30 to 8.60 mm, diameter of 7.90 to 10.40mm.

Inclusion Criteria

  • Age 18 or older.
  • Diagnosis of keratoconus.
  • Available baseline corneal topography and pachymetry
  • Amsler-Krumeich keratoconus classification of stage 1 or higher

Exclusion Criteria

  • No prior corneal transplantation or INTACTS
  • No prior use of hybrid, corneal or scleral gas permeable lenses
  • Presence of corneal scarring

Study procedures During the initial study visits patient demographics, past ocular and medical history and best corrected visual acuity with manifest refraction will be recorded. Additional testing may include corneal topography, pachymetry and meibography. Dry eye symptoms and contact lens comfort will be assessed using the OSDI and CLDEQ questionnaires.

Participants will be fit according to standard practices with the RoseK 2 corneal gas permeable and Synergeyes VS scleral lenses following manufacturer's recommendations. Over refraction and best corrected visual acuity will be recorded. Subjective comfort with lens use rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

Participants will be randomized to dispense lens #1 vs lens #2. They will be trained in safe application and removal and provided instructions on lens disinfection procedures. Best corrected visual acuity with lens #1 and subjective comfort with lens use will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

At the next visit, participants will return wearing lens #1 for minimum of 3 hours. Best corrected visual acuity with lens #1 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

At the final visit, participants will return wearing lens #2 for minimum of 3 hours. Best corrected visual acuity with lens #2 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

The participant will make a final selection of lens of choice #1 or #2.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

32

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Illinois
      • Chicago, Illinois, Forenede Stater, 60616
        • Illinois Eye Institute
      • Chicago, Illinois, Forenede Stater, 60612
        • University of Illinois at Chicago Eye and Ear Infirmary
    • Minnesota
      • Rochester, Minnesota, Forenede Stater, 55905
        • Mayo Clinic
    • Ohio
      • Columbus, Ohio, Forenede Stater, 43210
        • The Ohio State University College of Optometry

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Diagnosis of keratoconus
  • Available baseline corneal topography and pachymetry
  • Amsler-Krumeich keratoconus classification9 of stage 1

Exclusion Criteria:

  • No prior corneal transplantation or INTACTS
  • No prior use of hybrid, corneal or scleral gas permeable lenses
  • Presence of corneal scarring.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Andet
  • Tildeling: Randomiseret
  • Interventionel model: Crossover opgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Corneal gas permeable lens first

Device: corneal gas permeable contact lenses (RoseK2 corneal Blanchard Contact Lens, Inc. Manchester, NH).

Participants with an odd study ID will be fit with the corneal gas permeable lens first.

Fit in corneal gas permeable contact lens first.

Aktiv komparator: Scleral lens first

Device: scleral lenses (SynergEyes VS (Synergeyes, Inc., Carlsbad CA).

Participants with an even study ID will be fit with the scleral lens first.

Fit in corneal gas permeable contact lens first.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Final contact lens choice
Tidsramme: At study completion (6-24 weeks)

Each study participant will select whether to continue with Lens 1 or Lens 2. The percentage of those who choose a Scleral Lens will be compared to the percentage of participants who select corneal gas permeable lenses.

At study completion (6-24 weeks)

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Subjective comfort with lens use
Tidsramme: Baseline, Study Visit 1 (2-4 weeks), Study Visit 2 (4-10 weeks) and at study completion (6-24 weeks)

Subjective comfort with lens use will be rated by participants on comfort scale of 0 (not comfortable) to 10 (very comfortable).

Baseline, Study Visit 1 (2-4 weeks), Study Visit 2 (4-10 weeks) and at study completion (6-24 weeks)

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Efterforskere

  • Ledende efterforsker: Ellen S Shorter, OD, University of Illinois Chicago

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

23. juli 2021

Primær færdiggørelse (Faktiske)

15. maj 2026

Studieafslutning (Faktiske)

15. maj 2026

Datoer for studieregistrering

Først indsendt

14. maj 2021

Først indsendt, der opfyldte QC-kriterier

4. juni 2021

Først opslået (Faktiske)

8. juni 2021

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

13. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

9. november 2026

Sidst verificeret

1. maj 2026

Mere information

Begreber relateret til denne undersøgelse

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • 2020-1504

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

produkt fremstillet i og eksporteret fra U.S.A.

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .