Kvantificering af snavs opfanget ved hjælp af TCEP under VIV TAVR med BVF
Kvantificering af snavs opfanget ved hjælp af transkateter cerebral embolisk beskyttelse (TCEP) under ventil i ventil Transkateter aortaklapudskiftning (VIV TAVR) med bioprotetisk klapfraktur (BVF)
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
Undersøgelsestype
Undersøgelsestype
Tilmelding (Anslået)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiekontakt
Studiekontakt
- Navn: Sheila Erwin, RN
- Telefonnummer: 816-932-7996
- E-mail: serwin@saintlukeskc.org
Studiesteder
-
-
Missouri
-
Kansas City, Missouri, Forenede Stater, 64111
- Rekruttering
- Saint Luke's Hospital of Kansas City
-
Kontakt:
- Sheila Erwin, RN
- Telefonnummer: 816-932-7996
- E-mail: serwin@saintlukeskc.org
-
Ledende efterforsker:
- Adnan Chhatriwalla, MD
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Beskrivelse
Inklusionskriterier:
- Mænd og kvinder ≥ 18 år
- Patienten har alvorlig bioprotetisk aortaklapdegeneration (stenose, insufficiens eller blandet klapsygdom) og en klinisk indikation for VIV TAVR
- Den bioprotetiske ventil kan brækkes ved højtryksballonoppumpning.
- Patienten anses for at have uoverkommelig eller høj dødelighedsrisiko relateret til kirurgisk aortaklapudskiftning som vurderet af hjerteteamet
- Til procedureplanlægning skal alle patienter have et CT-angiogram af brystet, maven og bækkenet for at bekræfte:
A. Tilstrækkelig femoral adgang til TAVR-proceduren B. Passende højre subclavia, carotis og brachiocephalic samt venstre carotis arterie anatomi til SENTINEL-enhedens udbygning.
- Patienten eller den juridiske repræsentant er i stand til at forstå og villig til at give skriftligt informeret samtykke til at deltage i forsøget
- Patienten er i stand til og villig til at vende tilbage til nødvendige opfølgningsbesøg og undersøgelser
- Patienten vurderes af det multidisciplinære hjerteklapteam og vurderes at være egnet til proceduren.
Ekskluderingskriterier:
- Patienter med lav eller moderat dødelighedsrisiko ved kirurgisk udskiftning af aortaklap
- Patienter med bioprotetiske klapper, der ikke kan brækkes med standard ikke-kompatible klapklapballoner (tabel 1)
- Patienter med tegn på signifikant carotisarteriestenose (dvs. carotisstenose ≥ 50%), noteret på ultralyds-duplex-billeddannelse eller CT-angiografi.
- Patienter med tegn på stenose af højre subclavia/brachiocephalic arterie
- Patienter med dialysefistel eller graft til højre arm/underarm.
- Patienter med høstet højre radial arterie til en tidligere koronar bypass-operation.
- Patienter med uoverkommelige aortabue-anomalier til SENTINEL-enhedsimplantation.
- Patienten med anamnese med cerebrovaskulær hændelse (CVA) inden for 6 måneder.
- Patient med tilfældig trombe fra venstre atriel vedhæng noteret på TEE- eller CT-billeddannelse.
- Patienten er aktivt tilmeldt et andet forsøg med en kardiovaskulær enhed eller et forsøgslægemiddel (deltagelse efter markedsundersøgelse og registre er acceptable)
- Patienten er gravid, eller graviditet er planlagt i løbet af undersøgelsen, hvis patienten er i den fødedygtige alder
- Enhver klinisk signifikant medicinsk tilstand eller tilstedeværelse af enhver laboratorieabnormitet udført før randomisering, som af investigator anses for at være klinisk vigtig og kan forstyrre gennemførelsen af undersøgelsen eller ikke opfylde procedureretningslinjerne for TAVR eller SENTINEL
- Patienten har en forventet levetid på mindre end et år
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Andet: VIV TAVR med BVF ved hjælp af TCEP
Alle forsøgspersoner vil modtage interventionen.
|
Indsættelse og udtagning af SENTINEL-anordningen udføres på tidspunktet for patientens TAVR-procedure i samme indstilling, mens de er bedøvet under moderat sedation eller generel anæstesi afhængigt af tilfældet.
Enheden indsættes ved initieringen af proceduren gennem 6F højre radial arterie-adgang, og filtrene er placeret i venstre fælles halspulsåre og brachiocephalic arterie.
Efter deployering udføres den sædvanlige TAVR-procedure.
Ved afslutningen af proceduren udtrækkes SENTINEL-anordningen, og hæmostase opnås ved det radiale adgangssted på sædvanlig måde med patenteret hæmostase.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Mængde af affald
Tidsramme: Under kirurgisk indgreb
|
Mængden af snavs fanget af SENTINEL TCEP-enheden i VIV TAVR med BVF-patienter sammenlignet med historiske data
|
Under kirurgisk indgreb
|
|
Komplikationsrate
Tidsramme: Gennem hospitalsudskrivning i gennemsnit 2,5 døgn
|
Slagtilfælde på hospitalet, apparatets emboliseringshastighed, procedurerelateret større blødning
|
Gennem hospitalsudskrivning i gennemsnit 2,5 døgn
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Dødelighed
Tidsramme: Gennem hospitalsudskrivning i gennemsnit 2,5 døgn
|
Dødsfald af alle årsager
|
Gennem hospitalsudskrivning i gennemsnit 2,5 døgn
|
|
MACCE
Tidsramme: Gennem hospitalsudskrivning i gennemsnit 2,5 døgn
|
Større uønskede hjerte- og cerebrovaskulære hændelser
|
Gennem hospitalsudskrivning i gennemsnit 2,5 døgn
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Samarbejdspartnere
Samarbejdspartnere
Efterforskere
Efterforskere
- Ledende efterforsker: Adnan Chhatriwalla, MD, Saint Luke's Health System
Publikationer og nyttige links
Generelle publikationer
- Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S; PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010 Oct 21;363(17):1597-607. doi: 10.1056/NEJMoa1008232. Epub 2010 Sep 22.
- Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Williams M, Dewey T, Kapadia S, Babaliaros V, Thourani VH, Corso P, Pichard AD, Bavaria JE, Herrmann HC, Akin JJ, Anderson WN, Wang D, Pocock SJ; PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011 Jun 9;364(23):2187-98. doi: 10.1056/NEJMoa1103510. Epub 2011 Jun 5.
- Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, Gleason TG, Buchbinder M, Hermiller J Jr, Kleiman NS, Chetcuti S, Heiser J, Merhi W, Zorn G, Tadros P, Robinson N, Petrossian G, Hughes GC, Harrison JK, Conte J, Maini B, Mumtaz M, Chenoweth S, Oh JK; U.S. CoreValve Clinical Investigators. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014 May 8;370(19):1790-8. doi: 10.1056/NEJMoa1400590. Epub 2014 Mar 29.
- Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, Doshi D, Cohen DJ, Pichard AD, Kapadia S, Dewey T, Babaliaros V, Szeto WY, Williams MR, Kereiakes D, Zajarias A, Greason KL, Whisenant BK, Hodson RW, Moses JW, Trento A, Brown DL, Fearon WF, Pibarot P, Hahn RT, Jaber WA, Anderson WN, Alu MC, Webb JG; PARTNER 2 Investigators. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2016 Apr 28;374(17):1609-20. doi: 10.1056/NEJMoa1514616. Epub 2016 Apr 2.
- Fairbairn TA, Mather AN, Bijsterveld P, Worthy G, Currie S, Goddard AJ, Blackman DJ, Plein S, Greenwood JP. Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status. Heart. 2012 Jan;98(1):18-23. doi: 10.1136/heartjnl-2011-300065. Epub 2011 Jul 7.
- Ghanem A, Muller A, Nahle CP, Kocurek J, Werner N, Hammerstingl C, Schild HH, Schwab JO, Mellert F, Fimmers R, Nickenig G, Thomas D. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging. J Am Coll Cardiol. 2010 Apr 6;55(14):1427-32. doi: 10.1016/j.jacc.2009.12.026. Epub 2010 Feb 24.
- Kahlert P, Knipp SC, Schlamann M, Thielmann M, Al-Rashid F, Weber M, Johansson U, Wendt D, Jakob HG, Forsting M, Sack S, Erbel R, Eggebrecht H. Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation. 2010 Feb 23;121(7):870-8. doi: 10.1161/CIRCULATIONAHA.109.855866.
- Spaziano M, Francese DP, Leon MB, Genereux P. Imaging and functional testing to assess clinical and subclinical neurological events after transcatheter or surgical aortic valve replacement: a comprehensive review. J Am Coll Cardiol. 2014 Nov 4;64(18):1950-63. doi: 10.1016/j.jacc.2014.07.986. Epub 2014 Oct 27.
- Kapadia SR, Kodali S, Makkar R, Mehran R, Lazar RM, Zivadinov R, Dwyer MG, Jilaihawi H, Virmani R, Anwaruddin S, Thourani VH, Nazif T, Mangner N, Woitek F, Krishnaswamy A, Mick S, Chakravarty T, Nakamura M, McCabe JM, Satler L, Zajarias A, Szeto WY, Svensson L, Alu MC, White RM, Kraemer C, Parhizgar A, Leon MB, Linke A; SENTINEL Trial Investigators. Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement. J Am Coll Cardiol. 2017 Jan 31;69(4):367-377. doi: 10.1016/j.jacc.2016.10.023. Epub 2016 Nov 1.
- Allen KB, Chhatriwalla AK, Cohen DJ, Saxon JT, Aggarwal S, Hart A, Baron S, Davis JR, Pak AF, Dvir D, Borkon AM. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation. Ann Thorac Surg. 2017 Nov;104(5):1501-1508. doi: 10.1016/j.athoracsur.2017.04.007. Epub 2017 Jun 29.
- Chhatriwalla AK, Allen KB, Saxon JT, Cohen DJ, Aggarwal S, Hart AJ, Baron SJ, Dvir D, Borkon AM. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement. Circ Cardiovasc Interv. 2017 Jul;10(7):e005216. doi: 10.1161/CIRCINTERVENTIONS.117.005216.
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 21-109
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .