Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Den personlige KNÆ-forsøg

2. oktober 2026 opdateret af: Helse Møre og Romsdal HF

Robotassisteret kirurgi, der sammenligner personlig justering versus mekanisk justering af total knæarthroplastik - et randomiseret kontrolleret forsøg

Robotic knee surgery makes it possible to adopt different alignment philosophies in total knee arthroplasty. The classical operation where the knee is placed in a neutral manner, the so called mechanical alignment, has been used for decades. The kinematical alignment has recently won popularity. With this technique the focus is to render the natural knee anatomy even if this means to end up with a varus or valgus position. In this study, the investigators will compare the mechanical alignment and kinematical alignment and test the patients clinically and with a special CT scan to see if this technique gives equal or better longevity of the implants.

Studieoversigt

Status

Aktiv, ikke rekrutterende

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

Mechanical alignment (MA) has for many years been the most used surgical alignment technique in total knee arthroplasty (TKA). This means that regardless of constitutional native anatomy (i.e. valgus or varus), one strives to achieve a neutral coronal knee axis on postoperative x-rays (Hip-Knee-Ankle angle, HKA). To achieve MA, the cuts are made perpendicular to the mechanical axis, and subsequent soft tissue balancing is performed if necessary. However, many patients do not have a neutral knee alignment before they develop osteoarthritis. Several authors therefore advocate the personalized alignment (kinematic, KA or functional alignment, FA), where the aim is to restore the patient's original pre-arthritis anatomy and joint line. This means that tibial component placement in varus or valgus is accepted, despite the possible result of a postoperative non-neutral HKA axis. Studies indicate that good clinical results can be achieved in terms of range of motion (ROM) and patient reported outcome measures (PROMs) with these techniques, but it has not been tested properly in terms of activity measurements, strength testing or migration of implants. There is diversity in the literature regarding whether tibial component with too much deviation from a neutral axis can lead to increased migration and eventually aseptic solution. To date, only a few trials, with diverging results, have assessed migration of the implants implanted with KA or FA. The methods are so far perceived as controversial, despite the widespread use.

KA or FA can be performed by manual conventional surgery; however, the newly introduced robotic assisted surgery probably yields higher accuracy and precision of the cuts during surgery. This makes robotic assisted surgery well suited for personalized surgery. Yet, it is claimed that because of diversity of the different features for planning and executing the surgery, each system should be evaluated separately, and not as a group. The investigators therefore planned this study to assess the efficacy of robotic assisted surgery comparing MA and personalized alignment (PA) techniques.

Aims of the trial

  1. Evaluate the clinical outcomes of patients who have had TKA with PA and compare it with conventional MA.
  2. Analyse and compare the in vivo stability over time of TKA operated with PA vs. MA using CT- based radiostereometric analysis (CT-RSA).
  3. Evaluate the postoperative position of the implants using two different alignment philosophies.

Objective Perform TKAs on patients using ROSA® Knee System (Zimmer Biomet, Warsaw, Indiana USA) robotic assisted surgery and randomize the patients to either PA or MA.

Materials and methods

A multiple blinded randomized controlled parallel superiority trial will be performed, where the patients, study nurse, statistician and physiotherapists are blinded to the surgical method (PA or MA). The study will include 152 patients. The study adheres to the consort statement.

Surgery All surgeons involved in the trial are experienced knee surgeons. The surgeons have received thorough tutoring in the use of the ROSA Knee System and the Persona TKA, and both alignment techniques have now been adopted in our standard treatment of end stage OA. The learning curve of robotic assisted surgery is probably very small, and more related to time spent on the procedure rather than placement of the implants. The placement of the tibial implant will be restricted in the coronal plane to maximum 5 degrees of varus and 2 degrees of valgus. In sagittal plane, the slope will be limited to between 0-10 degrees.

The Persona TKA implant although contemporary, is a well-documented implant with very low migration.

The MA and PA techniques are well known and already used in a widespread fashion all around the world. Several clinics in Norway have also adopted the methods.

Implantation of tantalum markers in bone and polyethylene has been performed for more than 40 years in numerous studies without any known complications.

Known but rare complications to robotic surgery are fractures at the site of insertion of the bone pins, and pin site infections. In elderly or osteoporotic patients, the surgeons will consider using unicortical engagement of the pins. Concerning infections, all the default precautions in the OR will be taken, such as preoperative and postoperative administration of antibiotics, strict sterile procedures etc.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

160

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Møre and Romsdal
      • Kristiansund, Møre and Romsdal, Norge, 6508
        • Kristiansund Hospital, Møre and Romsdal Hospital Trust

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 80 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

• femoro-tibial or patello-femoral osteoarthritis (Kellgren-Lawrence, K-L) grade 2-4 with persistent pain, referred to Kristiansund Hospital for primary TKA

Exclusion Criteria:

  • serious psychiatric disorders
  • dementia
  • drug abuse
  • patients not able to speak and read Norwegian language making them noncompliant or unable to perform an informed consent
  • Patients with ongoing cancer therapy
  • Patients with ASA (The American Society of Anesthesiologists physical status class risk stratification system) classification >3
  • Patients in the need of walking aid devices
  • Patients in need of primary revision arthroplasty or more than 15 degrees of varus or 5 degrees of valgus on preoperative HKA images.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Tredobbelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Mechanical alignment

Patients are operated with ROSA robot and mechanical alignment

Mechanical or Personalized alignment

Eksperimentel: Personalized alignment

Patients are operated with ROSA robot and kinematic alignment

Mechanical or Personalized alignment

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
MTPM
Tidsramme: 2 years

Maximum Total Point Motion measured by CT -based RSA in millimeters.

2 years

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
XYZ translation
Tidsramme: 2 years

Translation of implant measured by CT -based RSA in millimeters

2 years
XYZ rotation
Tidsramme: 2 years

Rotation of implant measured by CT -based RSA in degrees

2 years
Steps per day
Tidsramme: 1 year and 2 years

ActivePAL accelerator registration of mean steps per day measured 24/7 for a week

1 year and 2 years
Walking speed
Tidsramme: 1 and 2 years

ActivePAL accelerator registration of mean meter per second measured 24/7 for a week

1 and 2 years
Stair climbing
Tidsramme: 1 and 2 years

Standardized climbing and descending of stairs up and down. Time in seconds measured up, down and total.

1 and 2 years
Maximal voluntary contraction flexion
Tidsramme: 1 and 2 years

Isometric contraction at 90 degrees knee flexion measured in Newtons with Tindeq force cell

1 and 2 years
Maximal voluntary contraction extension
Tidsramme: 1 and 2 years

Isometric contraction at 90 degrees knee extension measured in Newtons with Tindeq force cell

1 and 2 years
Maximal voluntary contraction
Tidsramme: 1 and 2 years

Isometric contraction at 90 degrees knee flexion measured in Newtons with Tindeq force cell

1 and 2 years
Sit to stand test
Tidsramme: 1 and 2 years

Maximum number of repetitive transitions from sitting on a chair to standing without the use of hands during 30 seconds

1 and 2 years
KOOS score
Tidsramme: 1 and 2 years

Knee Injury and Osteoarthritis of 5 dimensions measuring activity of daily living (ADL), Quality of life, Sport and recreation, pain and symptoms. From 0 (bad) to 100 (excellent)

1 and 2 years
FJS
Tidsramme: 1 and 2 years

Forgotten Joint Score is a 12 item scale assessing the ability to forget the operated joint as artificial during activities of daily living. Ranges from 0 (bad) to 100 (excellent)

1 and 2 years
Eq-5D
Tidsramme: 1 and 2 years

EuroQol 5 Dimensions is a generic patient reported outcome measure measuring quality of life. The scale ranges from 100 ('the best imaginable health state') to 0 ('the worst imaginable health state' ).

1 and 2 years
VAS
Tidsramme: 1 and 2 years

The Visual Analogue Scale (VAS) measures pain intensity. The VAS consists of a 10cm line, with two end points representing 0 ('no pain') and 10 ('pain as bad as it could possibly be')

1 and 2 years

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Samarbejdspartnere

Efterforskere

  • Studieleder: Frank-David Øhrn, MD, PhD, Møre og Romsdal Hospital Trust
  • Studiestol: Kirsti Sevaldsen, MD, PhD, Møre og Romsdal Hospital Trust

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Generelle publikationer

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

25. august 2024

Primær færdiggørelse (Anslået)

1. maj 2027

Studieafslutning (Anslået)

1. maj 2035

Datoer for studieregistrering

Først indsendt

8. juli 2024

Først indsendt, der opfyldte QC-kriterier

16. juli 2024

Først opslået (Faktiske)

18. juli 2024

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

5. oktober 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

2. oktober 2026

Sidst verificeret

1. oktober 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • 738578

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

JA

IPD-planbeskrivelse

Upon proper request to the corresponding author data will be shared anonymously.

IPD-delingstidsramme

After publication and for 2 years

IPD-deling Understøttende informationstype

  • STUDY_PROTOCOL
  • SAP
  • ICF

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .