Effect of Simethicone on Colon Preparation During Water Exchange Colonoscopy
Effects of Simethicone on Colon Preparation in Water Exchange Colonoscopies: a Randomized Controlled Study
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Anslået)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiekontakt
Studiekontakt
- Navn: Chih -Wei Tseng
- Telefonnummer: +886-5-2648000
- E-mail: cwtseng2@gmail.com
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Beskrivelse
Inclusion Criteria:
- Consecutive patients undergoing screening, surveillance, or diagnostic colonoscopy.
- Procedures performed by participating endoscopists.
- Ability to provide written informed consent.
Exclusion Criteria:
- Colonoscopy performed using air insufflation or water immersion technique.
- History of colorectal surgery (e.g., colectomy or colostomy).
- Known or suspected colonic obstruction or severe stricture.
- Requirement for inpatient bowel preparation.
- Known allergy or hypersensitivity to simethicone.
- Unable or unwilling to provide informed consent.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Sundhedstjenesteforskning
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Dobbelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Aktiv komparator: Without simethicone group
follow a bowel preparation protocol consisting of 10 mg of bisacodyl and 2 liters of PEG solution.
|
All participants followed a standardized bowel preparation protocol consisting of 10 mg of bisacodyl and 2 liters of PEG solution administered in a split-dose regimen.
|
|
Eksperimentel: With simethicone group
Participants received a total of 30 mL of simethicone, with 15 mL added to each 1-liter dose of polyethylene glycol (PEG) solution in the split-dose regimen.
|
All participants followed a standardized bowel preparation protocol consisting of 10 mg of bisacodyl and 2 liters of PEG solution administered in a split-dose regimen.
Participants in the simethicone group additionally received 30 mL of simethicone (600 mg), with 15 mL added to each 1-liter dose of PEG solution.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Boston bowel preparation scale (BBPS)
Tidsramme: At the time of colonoscopy.
|
Bowel preparation quality assessed using the Boston Bowel Preparation Scale (BBPS).
Adequate preparation is defined as a total score ≥6 with all segment scores ≥2.
|
At the time of colonoscopy.
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Bubble score assessed using a 4-point bubble scale
Tidsramme: During the colonoscopy procedure.
|
Bubble score assessed during colonoscopy using a 4-point scale (0-3) for each colon segment, where higher scores indicate more bubbles.
|
During the colonoscopy procedure.
|
|
Colon Endoscopic Bubble Scale(CEBuS)
Tidsramme: During the colonoscopy procedure.
|
Bowel cleanliness assessed using the Colon Endoscopic Bubble Scale (CEBuS), categorized based on the percentage of mucosal surface obscured by bubbles (e.g., <5%, 5-50%, >50%).Higher scores indicate poorer visibility due to bubbles.
|
During the colonoscopy procedure.
|
|
Adenoma detection rate (ADR)
Tidsramme: one week
|
one week
|
|
|
Polyp detection rate (PDR)
Tidsramme: one week
|
one week
|
|
|
Cecal intubation rate
Tidsramme: At the time of colonoscopy.
|
Proportion of procedures in which the cecum is successfully reached.
|
At the time of colonoscopy.
|
|
Cecal intubation time
Tidsramme: During the colonoscopy procedure.
|
Time from insertion to successful cecal intubation, measured in minutes.
|
During the colonoscopy procedure.
|
|
Withdrawal time
Tidsramme: During the colonoscopy procedure.
|
Time from cecal intubation to scope withdrawal, measured in minutes.
|
During the colonoscopy procedure.
|
|
Volume of water infused
Tidsramme: During the procedure.
|
Total volume of water infused during colonoscopy, measured in milliliters.
|
During the procedure.
|
|
Volume of fluid aspirated
Tidsramme: During the procedure
|
Total volume of fluid aspirated during colonoscopy, measured in milliliters.
|
During the procedure
|
|
Patient-reported pain score
Tidsramme: Immediately after the procedure.
|
Pain assessed using a visual analog scale (VAS) ranging from 0 (no pain) to 10 (worst pain imaginable).
|
Immediately after the procedure.
|
|
Patient satisfaction score
Tidsramme: Immediately after the procedure.
|
Patient satisfaction assessed using a numeric rating scale from 0 to 10, where higher scores indicate greater satisfaction.
|
Immediately after the procedure.
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Publikationer og nyttige links
Generelle publikationer
- Tongprasert S, Sobhonslidsuk A, Rattanasiri S. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation. World J Gastroenterol. 2009 Jun 28;15(24):3032-7. doi: 10.3748/wjg.15.3032.
- Sung H, Ferlay J, Siegel RL, Laversanne M, Soerjomataram I, Jemal A, Bray F. Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. CA Cancer J Clin. 2021 May;71(3):209-249. doi: 10.3322/caac.21660. Epub 2021 Feb 4.
- Zauber AG, Winawer SJ, O'Brien MJ, Lansdorp-Vogelaar I, van Ballegooijen M, Hankey BF, Shi W, Bond JH, Schapiro M, Panish JF, Stewart ET, Waye JD. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med. 2012 Feb 23;366(8):687-96. doi: 10.1056/NEJMoa1100370.
- Lebwohl B, Kastrinos F, Glick M, Rosenbaum AJ, Wang T, Neugut AI. The impact of suboptimal bowel preparation on adenoma miss rates and the factors associated with early repeat colonoscopy. Gastrointest Endosc. 2011 Jun;73(6):1207-14. doi: 10.1016/j.gie.2011.01.051. Epub 2011 Apr 8.
- Cao RR, Wang L, Gao C, Pan JH, Yoshida EM, Li HY, Qi XS. Effect of oral simethicone on the quality of colonoscopy: A systematic review and meta-analysis of randomized controlled trials. J Dig Dis. 2022 Mar;23(3):134-148. doi: 10.1111/1751-2980.13084. Epub 2022 Mar 14.
- Sun M, Yang G, Wang Y. Cleaning effect and tolerance of 16 bowel preparation regimens on adult patients before colonoscopy: a network meta-analysis. Int J Colorectal Dis. 2023 Mar 11;38(1):69. doi: 10.1007/s00384-023-04355-3.
- Zhang S, Zheng D, Wang J, Wu J, Lei P, Luo Q, Wang L, Zhang B, Wang H, Cui Y, Chen M. Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial. Endoscopy. 2018 Apr;50(4):412-422. doi: 10.1055/s-0043-121337. Epub 2017 Nov 13.
- Joao M, Areia M, Alves S, Elvas L, Brito D, Saraiva S, Cadime AT. The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial. GE Port J Gastroenterol. 2023 Jun 15;31(2):116-123. doi: 10.1159/000530866. eCollection 2024 Apr.
- Bai Y, Fang J, Zhao SB, Wang D, Li YQ, Shi RH, Sun ZQ, Sun MJ, Ji F, Si JM, Li ZS. Impact of preprocedure simethicone on adenoma detection rate during colonoscopy: a multicenter, endoscopist-blinded randomized controlled trial. Endoscopy. 2018 Feb;50(2):128-136. doi: 10.1055/s-0043-119213. Epub 2017 Oct 6.
- Moolla M, Dang JT, Shaw A, Dang TNT, Tian C, Karmali S, Sultanian R. Simethicone decreases bloating and improves bowel preparation effectiveness: a systematic review and meta-analysis. Surg Endosc. 2019 Dec;33(12):3899-3909. doi: 10.1007/s00464-019-07066-5. Epub 2019 Aug 26.
- Menees SB, Elliott E, Govani S, Anastassiades C, Judd S, Urganus A, Boyce S, Schoenfeld P. The impact of bowel cleansing on follow-up recommendations in average-risk patients with a normal colonoscopy. Am J Gastroenterol. 2014 Feb;109(2):148-54. doi: 10.1038/ajg.2013.243.
- Sharma P, Burke CA, Johnson DA, Cash BD. The importance of colonoscopy bowel preparation for the detection of colorectal lesions and colorectal cancer prevention. Endosc Int Open. 2020 May;8(5):E673-E683. doi: 10.1055/a-1127-3144. Epub 2020 Apr 17.
Datoer for undersøgelser
Studer store datoer
Studiestart (Anslået)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- A11403003
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .