Reduction in IV Associated Contamination
Reduction in Intraoperative Lumen Contamination of Standard 3-Way Open Lumen Stopcock Sets Through Use of a Novel, Passive Bundle
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
New Hampshire
-
Lebanon, New Hampshire, Vereinigte Staaten, 03756
- Dartmouth-Hitchcock Medical Center
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Adult patient undergoing surgery or procedure in operating room
- Undergoing general anesthesia
Exclusion Criteria:
- Children (age < 18 years)
- Lack of intravenous access
- failure of anesthesia provider to complete training on experimental device
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Verhütung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Kein Eingriff: Control
Control arm using standard of care operating room procedures and equipment
|
|
|
Experimental: Problem Solving Innovations (PSI) Experimental
Implementation of the passive bundle including HubScrub and DocIt
|
Implementation of passive bundle which includes HubScrub and DocIt device into the operating room environment.
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Presence of Bacterial IV Stopcock Lumen Contamination
Zeitfenster: 48 hours
|
The presence of bacteria in the stopcock lumen was assessed by analyzing swab cultures of the lumens.
Each swab potentially containing bacteria from any of the 3 lumens of the stopcock sets were analyzed
|
48 hours
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Presence of Positive Bacterial Culture in IV Stopcock Due to Effluent Contamination
Zeitfenster: Until positive, up to 5 days
|
Open lumen ports were removed from the patient; sent directly to the anesthesiology microbiology laboratory; connected by the same clinical laboratory scientist to sterile catheters using sterile, aseptic technique; and injected directly into a BacT/Alert 3D system (bioMérieux Inc., Durham, NC) with 2 mL of sterile saline per port.
BacT/Alert is a blood culture system that automatically monitors bacterial growth using colorimetry; a sensor inserted at the bottom of the bottle changes color on detecting the carbon dioxide produced by the growth of the bacteria.
Catheters were then removed, and the bottles were directly incubated in the BacT/Alert system for 5 days or until positive.
Once positive, the liquid in the bottle was examined to identify the organism.
|
Until positive, up to 5 days
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Mitarbeiter
Mitarbeiter
Ermittler
Ermittler
- Hauptermittler: Bryan S Brindeiro, MD, Dartmouth-Hitchcock Medical Center
- Studienleiter: Randy W Loftus, MD, Dartmouth-Hitchcock Medical Center
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Loftus RW, Koff MD, Burchman CC, Schwartzman JD, Thorum V, Read ME, Wood TA, Beach ML. Transmission of pathogenic bacterial organisms in the anesthesia work area. Anesthesiology. 2008 Sep;109(3):399-407. doi: 10.1097/ALN.0b013e318182c855.
- Koff MD, Loftus RW, Burchman CC, Schwartzman JD, Read ME, Henry ES, Beach ML. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device. Anesthesiology. 2009 May;110(5):978-85. doi: 10.1097/ALN.0b013e3181a06ec3.
- Loftus RW, Muffly MK, Brown JR, Beach ML, Koff MD, Corwin HL, Surgenor SD, Kirkland KB, Yeager MP. Hand contamination of anesthesia providers is an important risk factor for intraoperative bacterial transmission. Anesth Analg. 2011 Jan;112(1):98-105. doi: 10.1213/ANE.0b013e3181e7ce18. Epub 2010 Aug 4.
- Loftus RW, Brindeiro BS, Kispert DP, Patel HM, Koff MD, Jensen JT, Dodds TM, Yeager MP, Ruoff KL, Gallagher JD, Beach ML, Brown JR. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a passive catheter care system. Anesth Analg. 2012 Dec;115(6):1315-23. doi: 10.1213/ANE.0b013e31826d2aa4. Epub 2012 Nov 9.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- 22743
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .