Komplement (C1q)-Bindung an HLA-Antikörper in einem Festphasen-Immunoassay und klinische Wirkung auf die Thrombozytentransfusion
Background:
Platelets are blood cells that help blood clot. Some people have what is called thrombocytopenia. This means they have a low blood platelet count. They need platelet transfusions very often. Human leukocyte antigen (HLA) alloimmunization occurs for a lot of these people. They become refractory. This means their platelet levels no longer increase after transfusions. Researchers want to study a procedure that detects HLA antibodies. They want to test how well it predicts how a person will respond to a transfusion. They want to see if it does this better than the procedure that is usually used.
Objective:
To study the effect of C1q-binding of Class I HLA antibodies on platelet refractoriness in people who get platelet transfusions. To test if this method better predicts response to platelet transfusion than the IgG solid phase immunoassay method.
Eligibility:
People enrolled on protocols 11-C-0136, 08-H-0156, 03-C-0277, 01-C-0157, or 01-C-0129 who:
Agreed to have their specimens and data used for future research
Had Class I HLA antibodies detected by the IgG method
Had one or more platelet transfusions at NIH after the first positive HLA IgG antibody result
Design:
For each participant, researchers will look at a small portion of their archived plasma sample. The samples were left over from prior HLA antibody tests.
Participants samples will be analyzed. They will be tested to see if C1q-binding HLA antibodies are present. This will be done by solid phase immunoassay. Results will be compared with the past results of the IgG method.
Participants data will be stored in database that s protected by password.
...
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Detaillierte Beschreibung
Human leukocyte antigen (HLA) alloimmunization is common in patients undergoing frequent platelet transfusion, and is the most important cause of immune platelet refractoriness. Management strategies in HLA alloimmune platelet-refractory patients include transfusion with HLA-matched or crossmatched platelets; however, in broadly-sensitized patients, or in patients with uncommon HLA types, antigen-negative or epitope compatible donors may be difficult to find.
The Luminex immunoglobulin (Ig)G single-antigen-bead (SAB) solid phase immunoassay is now commonly used to detect HLA antibodies. However, an assay that specifically detects C1qbinding to HLA antibodies has been reported to identify a clinically relevant subset of HLA antibodies in solid organ transplantation; one group has studied the utility of this assay in platelet transfusion of HLA-alloimmunized platelet refractory patients. We intend to evaluate the ability of this C1-binding immunoassay to predict response to platelet transfusion in HLA alloimmune patients.
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Kontakte und Standorte
Studienorte
-
-
Maryland
-
Bethesda, Maryland, Vereinigte Staaten, 20892
- National Institutes of Health Clinical Center
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Beschreibung
-
INCLUSION CRITERIA:
- Class I HLA antibodies detected by the IgG solid phase immunoassay method
- Greater than or equal to 1 episode of platelet transfusion at NIH after the first positive HLA IgG antibody result
EXCLUSION CRITERIA:
1) Hyperproliferative thrombocytopenia
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Beobachtungsmodelle: COHORT
- Zeitperspektiven: RETROSPECTIVE
Anzahl der Gruppen / Kohorten
Kohorten und Interventionen
Gruppe / KohorteGruppe / Kohorte |
|---|
|
1
Previously selected HLA-alloimmunized platelet refractory, clinical, patients. |
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Corrected count increment after platelet transfusion
Zeitfenster: Retrospective
|
Corrected Count Increment |
Retrospective
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Ermittler
Ermittler
- Hauptermittler: Willy A Flegel, M.D., National Institutes of Health Clinical Center (CC)
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Loupy A, Lefaucheur C, Vernerey D, Prugger C, Duong van Huyen JP, Mooney N, Suberbielle C, Fremeaux-Bacchi V, Mejean A, Desgrandchamps F, Anglicheau D, Nochy D, Charron D, Empana JP, Delahousse M, Legendre C, Glotz D, Hill GS, Zeevi A, Jouven X. Complement-binding anti-HLA antibodies and kidney-allograft survival. N Engl J Med. 2013 Sep 26;369(13):1215-26. doi: 10.1056/NEJMoa1302506.
- Chen G, Sequeira F, Tyan DB. Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads. Hum Immunol. 2011 Oct;72(10):849-58. doi: 10.1016/j.humimm.2011.07.001. Epub 2011 Jul 18.
- Fontaine MJ, Kuo J, Chen G, Galel SA, Miller E, Sequeira F, Viele M, Goodnough LT, Tyan DB. Complement (C1q) fixing solid-phase screening for HLA antibodies increases the availability of compatible platelet components for refractory patients. Transfusion. 2011 Dec;51(12):2611-8. doi: 10.1111/j.1537-2995.2011.03194.x. Epub 2011 May 26.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Geschätzt)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- 999916155
- 16-CC-N155
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .