Instrumentelle Analyse des Gehens bei Menschen mit osseointegrierten Prothesen zur Amputation der unteren Extremitäten: Vergleichende Bewertung mit herkömmlichen Schaftprothesen (AStrO-OI)
The currently accepted standard for rehabilitation and mobility following amputation is a socket-mounted prosthesis. Osseointegration is an alternative method that has gradually gained greater acceptance in the last 30 years. It is defined as a procedure in which a metal implant is directly anchored to the residual bone, attached to a prosthetic limb using a transcutaneous connector.
The advantages of osseointegrated prostheses over conventional socket prostheses include stable fixation, significant increases in walking ability, range of motion and control of the prosthesis, and health-related quality of life. Moreover, bodyweight distribution results more similar to physiological conditions.
No formal consensus exists for osseointegration surgery. However, based on the positive clinical experience, surgeons currently indicate this surgery for those patients who show poor tolerance of socket prostheses.
The present study investigates neuro-physiologic and mechanical parameters of walking and balance in patients with lower limb amputation and osseointegrated prostheses and in matched patients with traditional socket prostheses to highlight strengths and weaknesses of the alternative technique with respect to the present standard of care.
The primary endpoint is the investigation of the neurologic and mechanic adaptation in terms of a) kinematic and dynamic segmental analysis of walking and transfer of the body center of mass during walking; b) capacity to retain balance in response to different conditions of oscillation, tilt, and translation of a posturographic platform.
The secondary endpoint is investigating of adaptation to walking on a split-belt treadmill mounted on force sensors with the belts running at different velocities.
We hypothesize that:
- the deficit in joint power of the prosthetic limb is associated with a phenomenon of "learned non-use" both in balance and during gait. This behavior looks automatic and unconscious. It consists of the under recruitment of the impaired side as a form of unconscious protection, which is adopted when the contralateral side may be exploited to carry out the function;
- the joint power provided by the prosthetic limb may increase both by increasing treadmill velocity and by walking in split-belt modality with the prosthetic limb on the faster belt;
- an "after-effect" will be evidenced after the split-belt walking test when the two belts will return to the same velocity; patients with osseointegrated prostheses and patients with socket prostheses may show different behaviors in the adaptation to split-belt walking and the following post-adaptation, as a result of the residual proprioception of the amputated limb.
Results from the present study will allow:
- the identification of the possible advantages in walking and balance symmetry in patients with osseointegrated prostheses with respect to patients with socket prostheses;
- the estimate of the sample size for future experimental protocols and new rehabilitative programs.
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Milan, Italien, 20122
- ASST Gaetano Pini-CTO
-
-
MI
-
Milan, MI, Italien, 20122
- Istituto Auxologico Italiano
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- unilateral lower extremity amputation;
- age > 18 years;
- amputation-adjusted Body Mass Index between 18 and 25;
- ability to understand the instructions;
- ability to wittingly sign the informed consent form.
Exclusion Criteria:
- other previous knee injuries or major surgical interventions at the lower limbs;
- comorbidities, such as neurological conditions, vascular diseases, or diseases of orthopedic, cardiac, or pulmonary origin;
- cancer disease in the site under examination;
- other neurological pathologies with impact on balance and gait.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Diagnose
- Zuteilung: Nicht randomisiert
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Keine (Offenes Etikett)
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Experimental: Patients with osseointegrated prostheses
Patients with an osseointegrated prosthesis following a lower limb amputation |
Tests of standing balance will be performed using the EquiTest System posturographic platform. Individuals will be requested to perform three tasks within the EquiTest battery: Sensory Organization test, Motor Control test backward/forward, Adaptation Test upward/downward. Gait analysis will be performed on a force sensorized split-belt treadmill. Participants will walk at increasing velocities from 0.2 m/s to the highest sustainable velocity in tied-belt condition. Velocity will be increased by 0.1 m/s every 20 consecutive strides. During gait analysis in the split-belt condition, participants will walk for 30 seconds with both belts at 0.4 m/s. Then, the velocity of the belt under the prosthetic limb will be increased to 1.2 m/s. After 6 minutes, the velocity of the faster belt will be restored at 0.4 m/s for 6 more minutes. Different combinations of velocities could be tested based on the patients' characteristics, maintaining a ratio of 3:1 between the velocities of the 2 belts. |
|
Experimental: Patients with socket prostheses
Patients with a socket-mounted prosthesis following a lower limb amputation |
Tests of standing balance will be performed using the EquiTest System posturographic platform. Individuals will be requested to perform three tasks within the EquiTest battery: Sensory Organization test, Motor Control test backward/forward, Adaptation Test upward/downward. Gait analysis will be performed on a force sensorized split-belt treadmill. Participants will walk at increasing velocities from 0.2 m/s to the highest sustainable velocity in tied-belt condition. Velocity will be increased by 0.1 m/s every 20 consecutive strides. During gait analysis in the split-belt condition, participants will walk for 30 seconds with both belts at 0.4 m/s. Then, the velocity of the belt under the prosthetic limb will be increased to 1.2 m/s. After 6 minutes, the velocity of the faster belt will be restored at 0.4 m/s for 6 more minutes. Different combinations of velocities could be tested based on the patients' characteristics, maintaining a ratio of 3:1 between the velocities of the 2 belts. |
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Joint power
Zeitfenster: Day 1
|
Joint kinematics will be recorded during walking through an optoelectronic method as per the Davis anthropometric model. The 3D displacement of the markers will be captured using 8 near-infrared stroboscopic cameras. Joint power will be computed through the spatiotemporal synchronization of ground reaction force vectors and the joint centers of rotation. The sagittal plane, only, will be considered for the analysis. Hip, knee, and ankle joint power will be computed as the product of joint torque and joint rotation speed. Power will be defined as positive or generated when the joint moment and rotation speed share the same directions (i. e., when agonist muscles are contracting while shortening), as negative or absorbed otherwise. Positive work will be computed as the integral of the generated (positive) power over time. |
Day 1
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Kinetic energy of the center of mass during walking
Zeitfenster: Day 1
|
Changes in kinetic energy during walking due to the forward (Ekf), lateral (Ekl), and vertical (Ekv) velocity will be computed. |
Day 1
|
|
Energy of the center of mass during walking due to vertical motion
Zeitfenster: Day 1
|
Changes in gravitational potential energy (Ep), and changes of the mechanical energy due to the vertical motion, Ev = Ekv+Ep, will be computed. |
Day 1
|
|
Total mechanical energy of the center of mass during walking
Zeitfenster: Day 1
|
Changes in total mechanical energy (Etot = Ekf+Ekl +Ev) will be computed. |
Day 1
|
|
Recovery of mechanical energy, R
Zeitfenster: Day 1
|
The amount of recovery of mechanical energy, R, due to the passive exchange between Ekf, Ev and Ekl, during walking, will be computed according to the equation R = (Wf + Wv + Wl - Wext)/(Wf + Wv + Wl) × 100, where Wf for Ekf, Wv for Ev, Wl for Ekl and Wtot for Etot represents the corresponding work values calculated as the sum of the positive increments of these energy values during one step. |
Day 1
|
|
SOT score
Zeitfenster: Day 1
|
The patient's task is to maintain an upright stance during three 20 s trials under six different conditions, including movements of the platform and the visual surround 'tuned' with the individual's sagittal oscillation. The SOT score will be calculated by comparing the sagittal oscillation of the body's center of mass (COM) to the maximal sagittal oscillation. The score is averaged across the six conditions (range 0-100. The higher the score, the lower the oscillation). |
Day 1
|
|
MCT score
Zeitfenster: Day 1
|
The patient's capacity to recover upright stance when the platform suddenly shifts forward or backward, thus causing the subject to lean back or forward with respect to the ground. The score is the latency between the onset of translation and the rise of a compensatory torque. Average latency between legs, repetitions and stimulus amplitude (36 values overall) is computed. The score is given in ms (the lower, the better). |
Day 1
|
|
ADT score
Zeitfenster: Day 1
|
The patient's capacity to minimize body sway when the platform suddenly tilts upward or downward, thus causing the body to lean backward or forward with respect to the ground, respectively. A non-dimensional parameter from a 'sway-energy function' is calculated. The function provides an 'energy' parameter derived from the root mean square of speed and acceleration of the position of the centre of pressure on the force plate during the tilt (range 0 to infinite, the lower, the better). |
Day 1
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Mitarbeiter
Mitarbeiter
Ermittler
Ermittler
- Hauptermittler: Luigi Tesio, MD, Professor, Istituto Auxologico Italiano
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- 24X101
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .