Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Ti-Mesh-Rahmenvergleich für die Alveolarknochenaugmentation

29. September 2026 aktualisiert von: Boston University

Augmentation des menschlichen Alveolarknochens: Vergleich eines 3D-CAD-CAM-Ti-Mesh-Rahmens mit einem herkömmlichen Ti-Mesh-Rahmen, der zum Zeitpunkt der Operation hergestellt wurde

This research compares a chairside Titanium Mesh frame fabrication used during bone grafting procedures with the use of a computer-aided design/computer-assisted manufacture (CAD-CAM) Titanium Mesh frame. In addition, a novel method of measuring soft tissue thickness will be tested using an Optical scanner at various times during the sequence of surgeries.

The device used for shaping is a very thin, perforated titanium metal sheet with numerous small perforations (referred to as Micromesh). The construction of this device is usually accomplished chairside at the time of the surgery with custom cutting and shaping done using cues from the geometry of the surgical defect. An alternative approach will be tested where the mesh is pre-designed using digital information provided by a special xray and an optical scan device which takes a digital impression of the tooth and soft tissue surface. A digitally designed frame can then be printed using CAD-CAM software prior to surgery. This should reduce surgical time.

A randomized control trial of 30 patients needing 3-D bone augmentation will be conducted comparing chairside fabrication of Ti-MESH or TEST- CAD-CAM designed and preprinted Ti-MESH to investigate these objectives:

  1. Compare the operative times required for placement and removal of two different Ti-MESH frame fabrications
  2. Compare post-op wound healing -Ti MESH exposure rates, bone production (volume, contour, and quality) and soft tissue thickness changes during the 1-year study period.

Studienübersicht

Status

Anmeldung auf Einladung

Bedingungen

Intervention / Behandlung

Studientyp

Interventionell

Einschreibung (Geschätzt)

30

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Massachusetts
      • Boston, Massachusetts, Vereinigte Staaten, 02118
        • BU Goldman School of Dental Medicine

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 80 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Partially edentulous
  • Adult dental patients that require moderate 3-D bone augmentation for dental implant site improvement

Exclusion Criteria:

  • Poor oral hygiene indices for microbial plaque (PI) and gingival inflammation (GI)
  • Patients who have been on Chemotherapy or Radiation therapy within last 5 years.
  • Patients under active treatment with following medications: Bisphosphonates, Gabapentin, Glucocorticoids, Methotrexate, or Estrogen supplements.
  • Subjects under the direct supervision of the PI
  • Smoking more than 10 cigarettes per day
  • Uncontrolled diabetes or other metabolic disorders

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: CAD-CAM Ti-Mesh frame

Participants randomized into this arm will have their tooth loss treated with CAD-CAM designed and preprinted Ti-MESH during surgery.

CAD-CAM technology which is the process of designing and manufacturing a custom-made dental device, or a patient-specific dental device from an industrialized product, with the aid of a computer.will be used to plan and preprint a 3-D Ti-Mesh frame prior to the surgery.

Aktiver Komparator: Conventional Ti-Mesh frame

Participants randomized into this arm will have their tooth loss treated with conventional chairside fabrication of Ti-MESH during surgery.

A three-dimensional frame or cage of Ti-Mesh or Ti-reinforced d-polytetrafluoroethylene (PTFE) will be fashioned during the surgery to contain, shape and stabilize the bone graft materials (the internal scaffold). This 3-D frame will be custom fabricated from a perforated Ti Mesh sheet material at the time of surgery which takes considerable time and skill.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Bone contour accuracy
Zeitfenster: 5 months post op

Bone contour accuracy will be derived by merger of the post op Cone beam computed tomography (CBCT) DICOM file with the CBCT-1/CEREC-1/Virtual Implant file produced at the planning stage. Accuracy of fit will be calculated for volume and linear measures (4 sides of each implant-MDBL) horizontal and vertical from the implant restorative platform.

5 months post op
Total surgical time
Zeitfenster: 2 hours

Total surgical time is defined as from incision time to completion of sutures and will be measured in minutes.

2 hours
Surgical exposure time for recipient site
Zeitfenster: 5 minutes

Surgical exposure time will be measured for recipient site in minutes

5 minutes

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Ti-Mesh exposure incidence
Zeitfenster: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Number of exposures

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Ti-Mesh exposure size
Zeitfenster: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Ti-Mesh exposure size will be measured in millimeters

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Ti-Mesh exposure location
Zeitfenster: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Ti-Mesh exposure location will be documented within mucosa, gingiva, or at the incision line

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Percentage of Vital bone
Zeitfenster: 6 months

Percentage of vital bone will be measured in histologic sections of bone core taken at time of implant surgery.

6 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Hauptermittler: Serge Dibart, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
  • Studienleiter: Albert M Price, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

25. Januar 2024

Primärer Abschluss (Geschätzt)

1. September 2027

Studienabschluss (Geschätzt)

1. Dezember 2027

Studienanmeldedaten

Zuerst eingereicht

5. Oktober 2023

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

5. Oktober 2023

Zuerst gepostet (Tatsächlich)

11. Oktober 2023

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

1. Oktober 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

29. September 2026

Zuletzt verifiziert

1. September 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • H-43856
  • AP 37 (Andere Kennung: Geistlich Pharma North America Inc)

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .