Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Gepulste Feldablation im Vergleich zur konventionellen Hochfrequenzkatheterablation für wiederholte PVI bei Patienten mit paroxysmalem Vorhofflimmern (REPEAT-AF)

24. November 2026 aktualisiert von: University Medical Center Groningen

Gepulste Feldablation im Vergleich zur konventionellen Hochfrequenzkatheterablation zur Wiederholung

Various methods exist for performing pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF), including thermal ablation and pulse-field ablation (PFA). However, in cases requiring a second PVI for recurrent AF, radiofrequency ablation (RFA) is utilized in nearly 95% of instances post-acquiring a 3D high-density map from the left atrium (LA). Up to 85% of patients experiencing recurrent AF after the initial PVI exhibit pulmonary vein (PV) reconnections, often identified as the cause of AF.

PFA has demonstrated its safety and efficiency compared to RFA as a swift technique for performing ablation. Yet, whether PFA or RFA stands out as superior or safer when applied for a second PVI remains unclear, as no randomized controlled trial has investigated this comparison. The proposed REPEAT-AF trial aims to randomize 154 AF patients experiencing recurrent AF after the initial PVI, assigning them in a 1:1 ratio to either RFA or PFA. Each patient will receive an implantable cardiac monitor to precisely detect any AF recurrences.

Studienübersicht

Status

Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

All participating patients are required to provide written (or equivalent) informed consent, indicated by a dated signature of the subject or legal representative. The consent process must comply with applicable national regulations and use language understandable by the patient.

The study will be conducted at 6 clinical centres/investigational sites across the Netherlands. Patients will be randomized (1:1) into a PFA or point-by-point RF ablation arm. Randomization will occur prior to the ablation procedure. A implantable cardiac monitor will be implanted in all randomised patients one month before ablation to accurately monitor any AF/atrial flutter (AFL)/ atrial tachycardia (AT) recurrence. Treatment allocation will be processed through the Dutch 'National Heart Registry' (NHR) data platform.

Patients randomized to both arms of the study will be evaluated for PV isolation at the start of the ablation procedure. If PV reconnection is identified in patients in the point-by-point RF arm, re-ablation will occur according to the study protocol. Patients in the PFA arm will have PV reconnection determined using the FARAWAVE catheter. Those with no PV reconnection (100% PV isolation/durable PVI) will be followed in an observational registry.

The PFA ablation arm involves the use of the Farastar generator system, Farawave ablation catheter, and Faradrive steering catheter for the procedure. The RF point-by-point ablation arm (control) involves RF ablation following standard practice.

Studientyp

Interventionell

Einschreibung (Geschätzt)

154

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Studienorte

    • Provincie Groningen
      • Groningen, Provincie Groningen, Niederlande, 9713GZ

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 80 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Subjects who meet all of the following inclusion criteria at screening will be eligible for enrolment:

  • Patient had 1 previous PVI with either cryoballoon, RF ablation or PFA
  • Index PVI occurred within <5 years prior to enrolment
  • Documented AF recurrence >30 seconds
  • Symptomatic AF
  • Paroxysmal AF
  • Age >18 and <80 years
  • Willing and capable to provide informed consent
  • Able and willing to participate in all examinations and follow-up visits and tests associated with this clinical study

Subjects who meet ANY of the following exclusion criteria will be excluded from the study:

  • Persistent AF (by diagnosis of duration >7 days)

  • Concomitant/ prior diagnosis for atrial tachycardia (AT) and/or atrial flutter (AFl). Note typical cavotricuspid isthmus dependent flutter is not an exclusion criterium.

  • Underwent additional ablations outside the pulmonary veins during index AF ablation

  • AF secondary to electrolyte imbalance, thyroid disease, alcohol abuse, or other reversible/non-cardiac causes

  • Contraindication to, or unwillingness to use, systematic anticoagulation

  • Left ventricular ejection fraction (LVEF) <30% as documented by transthoracic echo (TTE) (within <3 months prior)

  • Left atrial volume index >60 ml/m2

  • Clinically significant arrhythmias other than AF

  • Previous surgery for AF

  • New York Heart Association (NYHA) Functional Class III or IV

  • Presence of intramural thrombus, tumour or other abnormality that precludes safe catheter introduction or manipulation

  • BMI >35 kg/m2

  • Significant or symptomatic hypotension, bradycardia, or chronotropic incompetence

  • Chronic renal insufficiency of <15 mL/min/1.73 m2 or any history of renal dialysis, or history of renal transplant

  • Hemodynamically significant valvular disease

  • Presence of patent foramen ovale (PFO) or atrial septal defect (ASD) closure device

  • History of abnormal bleeding and/or clotting disorder

  • History of rheumatic fever

  • Severe lung disease, pulmonary hypertension, or any lung disease. Only if involving abnormal blood gases or significant dyspnoea

  • Clinically significant systemic infection or sepsis

  • Life expectancy <1 year

  • Sensitivity to contrast media not controlled by pre-medication

  • Any of the following within the 3 months prior to enrolment:

    • Myocardial infarction
    • Unstable angina
    • Percutaneous coronary intervention
    • Heart failure hospitalization
    • Stroke or TIA
    • Significant bleeding
    • Pericarditis/effusions
    • Left atrial thrombus
  • Coronary artery bypass grafting/atriotomy within 6 months prior

  • Organ or haematologic transplant, or currently being evaluated for an organ transplant

  • Women who are pregnant or breastfeeding

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Single

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: Radiofrequency ablation

In this group, patients will undergo the acquisition of a 3D high-density map. If pulmonary vein (PV) reconnection is identified, radiofrequency ablation (RFA) will be employed for pulmonary vein isolation (PVI). Should PV reconnection not be detected, the operator will have the discretion to determine the necessary ablation strategies. Patients falling into this category will be included in a concurrent registry.

Patients randomised to RFA will undergo PVI with point-by-point RFA.

Experimental: Pulsed field ablation

In this group, pulmonary vein (PV) reconnection is identified by the FARAWAVE system. If reconnection is observed, pulsed field ablation (PFA) will be employed for pulmonary vein isolation (PVI). Should PV reconnection not be detected, the operator will have the discretion to determine the necessary ablation strategies. Patients falling into this category will be included in a concurrent registry.

Patients randomised to PFA will undergo PVI with PFA.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
To compare the efficacy of repeat pulmonary vein isolation (PVI) with PFA or point-by-point RF ablation.
Zeitfenster: 12 months

12-month incidence of AF/AFl/AT recurrence.

12 months

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
To compare the efficacy of repeat pulmonary vein isolation (PVI) with PFA or point-by-point RF ablation.
Zeitfenster: 24 months

24-month incidence of AF/AFl/AT recurrence.

24 months
Repeat PVI within 12 and 24 months of randomization
Zeitfenster: 12 and 24 months

Repeat PVI

12 and 24 months
AF burden with and without 3 months blanking period
Zeitfenster: 12 and 24 months

Proportion of cumulative time in AF divided by the total time accrued over follow-up

12 and 24 months
Change in quality of life
Zeitfenster: 12 and 24 months

As measured by EuroQol-5D-5L questionnaire

12 and 24 months
Change in quality of life as affected by AF
Zeitfenster: 12 and 24 months

As measured by AF Effect On Quality-Of-Life (AFEQT) questionnaire

12 and 24 months
AF hospitalisation / urgent visit
Zeitfenster: 12 and 24 months

Hospitalization/urgent visit for atrial fibrillation

12 and 24 months
Cost-effectiveness
Zeitfenster: 12 and 24 months

Cost-effectiveness

12 and 24 months
Rate of ischemic stroke
Zeitfenster: 12 and 24 months (efficacy)

Rate of ischemic stroke

12 and 24 months (efficacy)
Complications of ablation
Zeitfenster: 0-30 days post ablation

Death, stroke, pericarditis, cardiac tamponade, vascular access complications etc.

0-30 days post ablation

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Mitarbeiter

Ermittler

  • Hauptermittler: Yuri Blaauw, Dr., University Medical Center Groningen

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

20. September 2024

Primärer Abschluss (Geschätzt)

1. Januar 2029

Studienabschluss (Geschätzt)

1. Januar 2029

Studienanmeldedaten

Zuerst eingereicht

1. Dezember 2023

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

9. Januar 2024

Zuerst gepostet (Tatsächlich)

10. Januar 2024

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

25. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

24. November 2026

Zuletzt verifiziert

1. November 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • REPEAT-AF trial

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .