Temporale Interferenzmethoden für die nicht-invasive Tiefenhirnstimulation, Studie 1.1
Temporale Interferenzmethoden für die nicht-invasive Tiefenhirnstimulation
In its totality, this grant aims to develop a line of research using temporal interference (TI) electrical neurostimulation technology to understand the causal role of deep brain structures in cognition. In the short term, the investigators aim to validate and characterize the effects of TI on brain activity as measured by fMRI and demonstrate its ability to focally stimulate deep brain regions without affecting overlying cortex. In the longer term, investigators aim to use these data to resolve longstanding debates about the function of deeper brain regions and lay the foundation for future clinical applications of TI for treating addiction, Obsessive-Compulsive Disorder (OCD), Parkinson's disease, and other disorders involving deep brain dysfunction. The grant supports 2 distinct aims, each of which will be evaluated through a series of independent studies.
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
Through the grant's duration, the investigators hypothesize that temporal interference (TI) electrical neurostimulation will be well tolerated and effective at focally manipulating deep brain activity as measured by functional MRI (fMRI) BOLD signals. The investigators will investigate whether TI stimulation can increase BOLD activity in targeted deep brain regions including the nucleus accumbens (NAcc) and dorsal anterior cingulate cortex (dACC), and whether this stimulation can influence cognitive functions controlled by these regions. TI works by applying alternating currents of slightly different frequencies through multiple electrode pairs, creating an interference pattern that can stimulate deep brain regions without significantly affecting superficial cortical areas. This method is similar to traditional transcranial direct current stimulation (tDCS), however TI can stimulate deeper brain structures that tDCS cannot reach effectively. The study is broken up into two main aims with multiple sub-studies. In Aim 1, the investigators will characterize the effects of TI on fMRI BOLD signals, test different beat frequencies, and compare TI effects in the nucleus accumbens versus dorsal anterior cingulate cortex. In Aim 2, the investigators will apply TI to the dorsal anterior cingulate cortex to test causal theories about its role in cognitive control, conflict monitoring, risk avoidance, and foraging behavior using established cognitive tasks while subjects undergo fMRI scanning.
Study 1.1 (Aim 1, Study 1) will test the ability to focally activate the nucleus accumbens without activating the overlying cortex, and also its effects on functional connectivity. Healthy subjects (n=30) will present for a single study visit during which they will be placed in the fMRI scanner and administered a temporal interference protocol. Specifically, subjects will have two pairs of carbon fiber electrodes attached to the scalp with conductive gel. They will receive one 8-minute block of stimulation at 2mA per electrode pair. The stimulation sequence will be 2 minutes on, 2 minutes off, 2 minutes on, and 2 minutes off with 30 second ramp up and ramp down beginning at the start of each 2-minute period. The first block will apply active TI stimulation with 2000Hz in one channel and 2020Hz in the other channel. The second block will be a sham TI stimulation, identical to the first block but with the "on" condition immediately ramping down as soon as it reaches 2mA after ramp up. The third and fourth blocks will be identical to the first and second blocks, except that both electrode pairs will stimulate at 2000Hz, resulting in a "NO-TI active" and "NO-TI sham" conditions. The order of blocks, and whether the "on" or "off" condition occurs first within a block, will be counterbalanced across subjects.
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Indiana
-
Bloomington, Indiana, Vereinigte Staaten, 47408
- Indiana University Bloomington, Imaging Research Facility
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Between the ages of 18 and 50
- Must have at least a 6th grade education
- Ability to speak and read English for all phases
Exclusion Criteria:
- Currently taking psychotropic medications for ADHD, other mental illness, or medications for cancer
- History of epilepsy or seizure disorders
- History of migraines or other neurological syndromes
- History of AIDS (due to potential cognitive deficits)
- History of head trauma or cognitive impairments
- Personal experiences consistent with symptoms of psychosis (e.g., hallucinations, delusions of control or special powers)
- History of skull defects (e.g., holes bored into the skull or known cranial fissures)
- Metal implants in the head or under the scalp
- Does not meet fMRI safety screening criteria (e.g., metal implants in the body, permanent jewelry, tattoos on the head or neck)
- Uses an intrauterine device (IUD) for birth control and cannot provide documentation to verify MRI safety
- Pregnancy (self-reported; no pregnancy test administered)
- Weight over 440 lbs (scanner weight limit)
- Presence of pacemakers
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Grundlegende Wissenschaft
- Zuteilung: Zufällig
- Interventionsmodell: Crossover-Aufgabe
- Maskierung: Single
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Aktiver Komparator: NAcc TI Active, then NAcc TI Sham, then NAcc No-TI Active, then NAcc No-TI Sham
Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc TI Active, then NAcc TI Sham, then NAcc No-TI Active, then NAcc No-TI Sham. |
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
|
|
Aktiver Komparator: NAcc No-TI Active, then NAcc No-TI Sham, then NAcc TI Active, then NAcc TI Sham
Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc No-TI Active, then NAcc No-TI Sham, then NAcc TI Active, then NAcc TI Sham. |
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
|
|
Aktiver Komparator: NAcc TI Sham, then NAcc TI Active, then NAcc No-TI Sham, then NAcc No-TI Active
Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc TI Sham, then NAcc TI Active, then NAcc No-TI Sham, then NAcc No-TI Active. |
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
|
|
Aktiver Komparator: NAcc No-TI Sham, then NAcc No-TI Active, then NAcc TI Sham, then NAcc TI Active
Participants in this Arm receive temporal interference (TI) electrical stimulation with two pairs of carbon fiber electrodes in this order: NAcc No-TI Sham, then NAcc No-TI Active, then NAcc TI Sham, then NAcc TI Active. |
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Active condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies (e.g., 2000 Hz and 2020 Hz) at up to 2 mA per electrode. This stimulation creates a beat frequency interference pattern (e.g., 20 Hz) that focally stimulates deep brain regions without activating overlying cortex. For the NAcc TI Sham condition, 2000Hz will be administered in one channel and 2020Hz in the other. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the Active TI condition), the stimulation in the NAcc TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Active condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles with a 30 second ramp up and ramp down beginning at the start of each 2 minute period.
Andere Namen:
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using the same current frequencies at up to 2 mA per electrode. For the NAcc No-TI Sham condition, 2000Hz will be administered in both channels. These frequencies will be administered in 2 minutes on/2 minutes off cycles, however, instead of the 30 second ramp up and ramp down at the beginning of each 2 minute period (as seen in the NAcc No-TI Active condition), the stimulation in the NAcc No-TI Sham condition will immediately ramp down as soon as it reaches 2mA after ramp up.
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change From Baseline (no Stimulation) in Brain Activity in the Nucleus Accumbens During Active Versus Sham Stimulation
Zeitfenster: During fMRI scanning for each study session (active and sham stimulation), approximately 60 minutes
|
Brain activity in the nucleus accumbens was measured using functional magnetic resonance imaging (fMRI) during active temporal interference (TI) brain stimulation compared to sham stimulation. Activity change from baseline (no stimulation) was quantified using region-of-interest (ROI) beta estimates extracted from the nucleus accumbens. The beta estimates were derived from blood-oxygen-level-dependent (BOLD) signal changes measured during fMRI and reflect the magnitude of task-related neural activation within the ROI. Higher beta values indicate greater task-related activation. Whole-brain voxelwise analyses did not identify statistically significant activation clusters after correction for multiple comparisons; therefore, descriptive ROI-level beta estimates are reported. |
During fMRI scanning for each study session (active and sham stimulation), approximately 60 minutes
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change From Baseline (no Stimulation) in Brain Activity in the Nucleus Accumbens During No-TI Active Versus No-TI Sham High-frequency Stimulation
Zeitfenster: During fMRI scanning for each study session (active and sham no-TI stimulation conditions), approximately 60 minutes
|
Brain activity in the nucleus accumbens was measured using functional magnetic resonance imaging (fMRI) during no-temporal interference (no-TI) control stimulation, in which both electrode pairs delivered the same frequency. Change in activity from baseline (no stimulation) was quantified using region-of-interest (ROI) beta estimates extracted from the nucleus accumbens during NO-TI active versus NO-TI sham high-frequency stimulation to determine whether high-frequency stimulation alone altered brain activity. The beta estimates were derived from blood-oxygen-level-dependent (BOLD) signal changes measured during fMRI and reflect the magnitude of task-related neural activation within the ROI. Higher beta values indicate greater task-related activation. Whole-brain voxelwise analyses did not identify statistically significant activation differences after correction for multiple comparisons; therefore, descriptive ROI-level beta estimates are reported. |
During fMRI scanning for each study session (active and sham no-TI stimulation conditions), approximately 60 minutes
|
|
Change From Baseline (no Stimulation) in Brain Activity in the Nucleus Accumbens During Active TI Stimulation Versus Active No-TI Stimulation
Zeitfenster: During fMRI scanning for each study session (active TI and active no-TI stimulation conditions), approximately 60 minutes
|
Brain activity in the nucleus accumbens was compared between active temporal interference (TI) stimulation and active high-frequency no-temporal interference (no-TI) stimulation using functional magnetic resonance imaging (fMRI). Change in activity from baseline (no stimulation) was quantified using region-of-interest (ROI) beta estimates extracted from the nucleus accumbens to determine whether TI stimulation produced greater task-related activation than high-frequency stimulation alone. The beta estimates were derived from blood-oxygen-level-dependent (BOLD) signal changes measured during fMRI and reflect the magnitude of task-related neural activation within the ROI. Higher beta values indicate greater task-related activation. Whole-brain voxelwise analyses did not identify statistically significant activation differences after correction for multiple comparisons; therefore, descriptive ROI-level beta estimates are reported. |
During fMRI scanning for each study session (active TI and active no-TI stimulation conditions), approximately 60 minutes
|
|
Change in Brain Connectivity Between the Nucleus Accumbens and Other Brain Regions During Stimulation
Zeitfenster: During fMRI scanning for each study session (active and sham stimulation conditions), approximately 60 minutes
|
Functional connectivity between the nucleus accumbens and other brain regions was planned to be evaluated using fMRI-based psycho-physiological interaction (PPI) analyses during active versus sham temporal interference (TI) stimulation. Higher correlation values indicate stronger functional connectivity between brain regions. The primary test statistic was the whole-brain interaction term between seed-region BOLD activity and stimulation condition (active vs. sham TI). This analysis was not performed because no statistically significant activation clusters were identified from which to define a seed region. |
During fMRI scanning for each study session (active and sham stimulation conditions), approximately 60 minutes
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Mitarbeiter
Mitarbeiter
Ermittler
Ermittler
- Hauptermittler: Joshua W Brown, PhD, Indiana University, Bloomington
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Grossman N, Bono D, Dedic N, Kodandaramaiah SB, Rudenko A, Suk HJ, Cassara AM, Neufeld E, Kuster N, Tsai LH, Pascual-Leone A, Boyden ES. Noninvasive Deep Brain Stimulation via Temporally Interfering Electric Fields. Cell. 2017 Jun 1;169(6):1029-1041.e16. doi: 10.1016/j.cell.2017.05.024.
- Violante IR, Alania K, Cassara AM, Neufeld E, Acerbo E, Carron R, Williamson A, Kurtin DL, Rhodes E, Hampshire A, Kuster N, Boyden ES, Pascual-Leone A, Grossman N. Non-invasive temporal interference electrical stimulation of the human hippocampus. Nat Neurosci. 2023 Nov;26(11):1994-2004. doi: 10.1038/s41593-023-01456-8. Epub 2023 Oct 19.
- Modak P, Fine J, Colon B, Need E, Cheng H, Hulvershorn L, Finn P, Brown JW. Temporal interference electrical neurostimulation at 20 Hz beat frequency leads to increased fMRI BOLD activation in orbitofrontal cortex in humans. Brain Stimul. 2024 Jul-Aug;17(4):867-875. doi: 10.1016/j.brs.2024.07.014. Epub 2024 Jul 24.
Nützliche Links
- <p>Lab website for study. The Cognitive Control Lab aims to understand the neural mechanisms of goal-directed behavior, using a combination of fMRI, computational neural modeling, and neurostimulation methods in healthy and clinical human populations.</p>
- <p>Project details for the NIMH-funded study on temporal interference stimulation, including abstract, funding, and key personnel.</p>
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- 26941, Study 1.1
- 1R21MH140210-01 (US NIH Stipendium/Vertrag)
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .