Evaluierung eines Prostata-zielgerichteten PET-Bildgebungssystems (P-PET) zur Erkennung von Prostatakrebs (P-PET)

Eine Pilotstudie zur Bewertung der Bildgebungsfähigkeit eines neuartigen Prostata-zielgerichteten PET-Systems (P-PET) zur Erkennung von Prostatakrebs

The goal of this study is to evaluate the imaging capabilities of a new prostate-targeted PET system (P-PET) and determine whether it could be useful in detecting prostate cancer by comparing SOC whole body PET imaging. This pilot study will include adult men who have been diagnosed with or are suspected to have prostate cancer. Participants will undergo a standard-of-care PET/CT scan followed by an additional P-PET scan designed to provide detailed images of the prostate. The images from the two scans to assess how well the P-PET system can detect prostate cancer.

Studienübersicht

Status

Noch keine Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

This pilot study will evaluate the performance of a novel prostate-targeted positron emission tomography (PET) imaging system (P-PET) in men undergoing PET imaging for primary staging of prostate cancer. This study is designed to assess the feasibility and diagnostic performance of this new imaging approach.

Participants will receive the standard-of-care PET radiotracer fluroine-18 PSMA-1007 (18F-PSMA-1007) as part of routine clinical PET imaging. While the tracer is circulating in the body, a research dynamic imaging sequence will be performed, followed by the standard-of-care whole body PET scan. Immediately after completion of the standard imaging, participants will undergo the research P-PET scan during the same imaging visit. No additional radiotracer will be administered for the P-PET scan, as it used the same tracer injection given for the standard-of-care PET imaging.

Images obtained from the P-PET system will undergo comparative analysis with the standard-of-care PET scan images to assess lesion detection, image quality and overall imaging performance. The findings from this study will provide preliminary data on feasibility and potential diagnostic value of the P-PET system and may guide future research in prostate-targeted PET imaging.

Studientyp

Interventionell

Einschreibung (Geschätzt)

25

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Studienorte

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Kind
  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Männlich

Beschreibung

Inclusion Criteria:

  • Qualitative comparison of PET scans acquired by the P-PET vs. WB PET

Exclusion Criteria:

  • Unable to comply with the length of scan time due to the study imaging.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Diagnose
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Standard-of-care PET Scan with Additional Dynamic and P-PET imaging.

This is a prospective, single-arm, pilot diagnostic study to evaluate the diagnostic study to evaluate the diagnostic accuracy of using dynamic PET, and P-PET in 25 patients with biopsy proven prostate cancer. This study will take place during the scheduled routine clinical PSMA PET/CT scan.

Participants will undergo a prostate-targeted PET scan to detect prostate cancer. This research scan is performed after the standard-of-care PET scan to evaluate its imaging capability. While the radioisotope is still active.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Qualitative comparison of PET scans acquired by the P-PET vs. WB PET
Zeitfenster: Baseline (Day1)

The primary outcome is the detection of prostate cancer lesions by the research prostate-targeted P-PET scan. Images from the P-PET scan will be compared to standard-of-care PET scan images to evaluate the sensitivity and clarity of the new imaging system in identifying cancerous lesions in the prostate.

Baseline (Day1)

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Number of Prostate Lesions Detected by P-PET Compared with Standard-of-care Whole-Body PET
Zeitfenster: Baseline (Day 1)

The number of pelvic lesions detected by P-PET in comparison with the number of lesions detected by standard-of-care whole body PET/CT.

Baseline (Day 1)

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Mitarbeiter

Ermittler

  • Hauptermittler: Stephen Pautler, BSc MD FRCSC, St. Joseph Health Care London

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

30. Dezember 2026

Primärer Abschluss (Geschätzt)

31. März 2028

Studienabschluss (Geschätzt)

1. April 2028

Studienanmeldedaten

Zuerst eingereicht

17. März 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

31. März 2026

Zuerst gepostet (Tatsächlich)

6. April 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

25. September 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

22. September 2026

Zuletzt verifiziert

1. September 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 15142

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .