Die Wirkung von Niedrigfluss- und Hochflussanästhesie auf den intrakraniellen Druck
Vergleichende Effekte von High-Flow- und Low-Flow-Anästhesie auf den Durchmesser der Sehnervenscheide und die zerebrale Oxygenierung während laparoskopischer Hysterektomie
This prospective randomized study was conducted to evaluate the effects of low-flow and high-flow anesthesia on intracranial dynamics and cerebral oxygenation in patients undergoing laparoscopic hysterectomy in the Trendelenburg position. Intracranial pressure was assessed noninvasively using optic nerve sheath diameter (ONSD), and cerebral oxygenation was monitored using near-infrared spectroscopy (NIRS). Changes in these parameters were assessed under standardized pneumoperitoneum and positioning conditions, and comparisons between anesthesia flow groups were performed according to the predefined study protocol.
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
Laparoscopic surgical procedures commonly involve the establishment of pneumoperitoneum (PP) and the application of the Trendelenburg position (TP) to optimize surgical exposure. These interventions are known to increase intra-abdominal pressure and may influence venous return, intrathoracic pressure, and cerebral hemodynamics. The combined use of pneumoperitoneum and Trendelenburg positioning is considered to have the potential to increase intracranial pressure (ICP). Therefore, the intraoperative assessment of intracranial dynamics is of clinical importance.
Optic nerve sheath diameter (ONSD) measurement is a noninvasive, reproducible, and bedside-applicable method used to assess changes in intracranial pressure. ONSD is considered to correlate with ICP alterations. Cerebral oxygenation can be evaluated using near-infrared spectroscopy (NIRS), a noninvasive technique that enables continuous monitoring of cerebral tissue oxygenation.
Low-flow anesthesia is based on the reduction of fresh gas flow rates and offers several advantages, including decreased anesthetic gas consumption, preservation of heat and humidity in the respiratory tract, and reduced environmental impact. However, data regarding the effects of low-flow anesthesia on cerebral physiology and intracranial dynamics remain limited. In surgical settings where pneumoperitoneum and Trendelenburg positioning are applied, evaluating the impact of different fresh gas flow rates on intracranial pressure and cerebral oxygenation is particularly important.
This prospective, randomized study was conducted in patients scheduled for elective laparoscopic hysterectomy at Bursa City Hospital. Patients aged between 18 and 75 years with an American Society of Anesthesiologists (ASA) physical status of I-II were included. Patients meeting predefined exclusion criteria were not enrolled in the study. Written informed consent was obtained from all participants prior to inclusion.
Patients were randomized into two groups using the closed-envelope method to receive either low-flow or high-flow anesthesia. Standard monitoring, including electrocardiography, noninvasive blood pressure, peripheral oxygen saturation, and NIRS monitoring, was applied to all patients. General anesthesia induction and maintenance were performed according to standardized protocols. Mechanical ventilation was provided in volume-controlled mode, and ventilator parameters were maintained within standard ranges.
Pneumoperitoneum was established using carbon dioxide (CO₂) insufflation at a predefined pressure range and was maintained throughout the surgical procedure. Following the establishment of pneumoperitoneum, patients were placed in the Trendelenburg position at a predefined angle, which was maintained during the operation.
Optic nerve sheath diameter measurements were performed using ultrasonography with minimal pressure applied to the globe. Measurements were obtained at predefined time points. Cerebral oxygenation was continuously monitored using NIRS throughout the intraoperative period. In addition, hemodynamic and respiratory parameters, including heart rate, arterial blood pressure, end-tidal carbon dioxide (EtCO₂), and ventilatory variables, were recorded.
Within the scope of this study, the effects of low-flow and high-flow anesthesia on intracranial dynamics and cerebral oxygenation were planned to be comparatively evaluated, and the study was conducted in accordance with the predefined protocol.
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Bursa, Türkei (türkiye), 16110
- Bursa City Hospital
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria
- Female patients aged 18-75 years
- Scheduled for elective laparoscopic hysterectomy
- American Society of Anesthesiologists (ASA) physical status I-II
- Ability to provide written informed consent
Exclusion Criteria
- Septicemia
- Risk of malignant hyperthermia
- Uncontrolled diabetes mellitus
- Chronic alcohol use
- Prolonged fasting
- Body mass index (BMI) > 40 kg/m²
- Intracranial space-occupying lesions (e.g., tumors, metastases, abscesses, hematomas, aneurysms)
- History of head trauma or cerebrovascular stroke within the preceding six months
- Known heart failure
- Diagnosis of glaucoma
- Prior carotid surgery or carotid artery stenosis
- ASA physical status ≥ III
- Requirement for massive blood transfusion
- Conversion from volume-controlled to pressure-controlled mechanical ventilation during surgery
- Intraoperative conversion to open surgery
- Patient refusal to participate
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Sonstiges
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Keine (Offenes Etikett)
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Experimental: LOW-FLOW ANESTHESİA
Patients in this group received general anesthesia with sevoflurane. Fresh gas flow was initially set at 3 L/min until a minimum alveolar concentration (MAC) of 1.0 was achieved, after which it was reduced to 1 L/min and maintained throughout the procedure. |
Patients assigned to the low-flow anesthesia group initially received a fresh gas flow of 3 L/min with a mixture of 50% oxygen and 50% air until a minimum alveolar concentration (MAC) of 1.0 was achieved. Subsequently, the fresh gas flow was reduced to 1 L/min, with oxygen and air concentrations maintained at 50-60% and 40-50%, respectively. Anesthesia was maintained with sevoflurane and a continuous remifentanil infusion. |
|
Experimental: HIGH-FLOW ANESTESIA
Patients assigned to the high-flow anesthesia group received general anesthesia with sevoflurane using a fresh gas flow rate of 3 L/min throughout the procedure. A gas mixture consisting of 50% oxygen and 50% air was administered, with a target minimum alveolar concentration (MAC) of 1.0. Remifentanil was administered as a continuous intravenous infusion at 0.05-0.1 μg/kg/min |
Patients assigned to the high-flow anesthesia group received a fresh gas flow of 3 L/min throughout the procedure, using a mixture of 50% oxygen and 50% air. Anesthesia was maintained with sevoflurane at a target minimum alveolar concentration (MAC) of 1.0, together with a continuous remifentanil infusion. |
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Optic Nerve Sheath Diameter
Zeitfenster: 1-4 hour
|
To determine the differences between the two groups of trendelenburg and pneumoperitoneum, which increase intracranial pressure. |
1-4 hour
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Cerebral Oxygenation
Zeitfenster: 1-4 hour
|
To determine the effects of low-flow and high-flow anesthesia on cerebral oxygenation in conditions that increase intracranial pressure. |
1-4 hour
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Ishiyama T, Kotoda M, Asano N, Ikemoto K, Shintani N, Matsuoka T, Matsukawa T. Effects of hyperventilation on cerebral oxygen saturation estimated using near-infrared spectroscopy: A randomised comparison between propofol and sevoflurane anaesthesia. Eur J Anaesthesiol. 2016 Dec;33(12):929-935. doi: 10.1097/EJA.0000000000000507.
- Mermer A, Kozanhan B. Comparison of the effects of low-flow and normal-flow anesthesia on intracranial pressure, cerebral oxygenation and bispectral index in laparoscopic cholecystectomy operation. Eur Rev Med Pharmacol Sci. 2023 Sep;27(18):8514-8522. doi: 10.26355/eurrev_202309_33776.
- Hanel F, Blobner M, Bogdanski R, Werner C. Effects of carbon dioxide pneumoperitoneum on cerebral hemodynamics in pigs. J Neurosurg Anesthesiol. 2001 Jul;13(3):222-6. doi: 10.1097/00008506-200107000-00007.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- 2023-17/2
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Beschreibung des IPD-Plans
Protecting patient privacy and ensuring the security of patient personal information is paramount. However, in our study, some data can be shared without compromising patient safety.
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .