Enhancing Voluntary Motion in Broad Patient Populations With Modular Powered Orthoses Renewal

22. Juni 2026 aktualisiert von: Robert D Gregg, University of Michigan
The overall goal of this project is to establish a novel design and control paradigm for modular, partial-assist powered orthoses (exoskeletons) to enhance voluntary lower-limb motion and manage pain in broad patient populations. Building upon a previous study period that addressed weakness from advanced age or muscle fatigue, this current period extends the technology to novel powered unloader orthoses designed to manage knee osteoarthritis (OA) pain. The investigators hypothesize that by providing 15-30% of biological joint torque, these motorized devices can reduce muscular contributions to painful loads on the joint's surfaces during activities of daily living (ADLs). The project aims to develop a task-agnostic, neural network-based controller and establish the feasibility of reducing knee pain and muscle effort in individuals with multi-compartment knee osteoarthritis.

Studienübersicht

Status

Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

The overall goal of this project is to develop modular, lower-limb, powered orthoses that fit to user-specific joints and control torque in a manner that enhances voluntary motion and mitigates musculoskeletal pain. Commercial exoskeletons typically use actuation and control methods that force the human user to follow specific, rigid gait patterns. This has prevented emerging wearable robotics from effectively addressing the weakness and pain associated with mild to moderate impairments, such as knee osteoarthritis (OA). These populations require partial, task-agnostic assistance that works harmoniously with their voluntary motion rather than constraining it.

To bridge this gap, this project utilizes a quasi-direct drive actuation paradigm, a high-torque motor combined with a low-ratio transmission, integrated into conventional knee stabilizer and unloader braces. This hardware is uniquely capable of producing large output torques without causing perceptible resistance when backdriven by the human joint. To control the device across various activities of daily living (ADLs) without requiring pre-programmed trajectories, the investigators are developing a neural network-based formulation of "energy shaping" (effectively combining virtual springs, dampers, and gravity/inertia compensation) trained on multi-activity human data.

The specific objectives of this study period are to:

  1. Integrate the modular quasi-direct drive actuator and miniaturized electronics into both a modified knee stabilizer brace and a modified unloader knee brace.
  2. Implement and validate the neural network-based energy shaping controller to provide task-agnostic, biomimetic torque assistance with able-bodied subjects.
  3. Establish the clinical feasibility of this technology in individuals with multi-compartment knee OA.

The investigators hypothesize that the biomimetic torque assistance provided by these motorized braces will significantly reduce quadriceps effort, knee joint moment loads, and subjective pain across ADLs.

Studientyp

Interventionell

Einschreibung (Geschätzt)

65

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Studienorte

    • Michigan
      • Ann Arbor, Michigan, Vereinigte Staaten, 48109
        • Rekrutierung
        • Rehab Lab
        • Kontakt:
        • Hauptermittler:
          • Robert Gregg

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Ja

Beschreibung

Inclusion Criteria:

Inclusion criteria for able-bodied, young participants will be:

  • Aged between 18 to 65 years
  • Weigh less than 300 lbs (due to challenges in bracing heavier participants)
  • BMI < 40 (due to challenges in bracing heavier participants)

Inclusion criteria for knee osteoarthritis participants will be:

  • Aged between 30 to 85 years
  • Medical diagnosis of patellofemoral and tibiofemoral osteoarthritis
  • Patient reported pain ≥ 4 out of 10 during activities of daily life (to avoid floor effects)
  • Weigh less than 300 lbs (due to challenges in bracing heavier participants)
  • BMI < 40 (due to challenges in bracing heavier participants)
  • Ability to walk 6 minutes without assistance from a person (may use walking aid)
  • Ability to ascend/descend ramps and stairs with or without the use of handrails

Exclusion Criteria:

Exclusion criteria for able-bodied, young adult participants will be:

  • Pregnant (self-report)
  • Any significant neuromuscular or musculoskeletal disorder that would interfere with the study
  • Unable to walk for 20 minutes
  • History of any cardiovascular, vestibular, or visual diseases and/or impairments that may interfere with the study
  • Cognitive deficits that would impair their ability to give informed consent or impair their ability to follow simple instructions during the experiments. Cognitive deficits will be determined by a Mini-Mental State Examination (MMSE) score of <22.
  • Adults with a known allergy to medical grade tape

Exclusion criteria for knee osteoarthritis participants will be:

  • Pregnant (self-report)
  • Any recent lower-extremity fracture (within 6 months)
  • Significant limitation on knee joint range of motion
  • Significant neurological (e.g., stroke) or cardiovascular disorder that may affect the ability to walk
  • Advised by a physician not to walk or exercise
  • Uncontrolled hypertension or diabetes
  • Use of opioids
  • Cognitive deficits or visual impairment that would impair their ability to give informed consent or impair their ability to follow simple instructions during the experiments. Cognitive deficits will be determined by a Mini-Mental State Examination (MMSE) score of <22.
  • Adults with a known allergy to medical grade tape

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Sonstiges
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Exoskeleton

Experimental: Exoskeleton

Participants in this arm of the study will perform various tasks while wearing the modular powered orthosis

In dieser Studie werden modulare, angetriebene Orthesen für die unteren Gliedmaßen untersucht, die sich an benutzerspezifisch geschwächte Gelenke anpassen und Kraft/Drehmoment auf eine Weise steuern, die die willkürliche Bewegung bei breiten Patientenpopulationen verbessert. Die zentrale Hypothese ist, dass motorische Systeme mit hohem Drehmoment und geringer Trägheit, die mit energetischen Zielen gesteuert werden, es modularen Orthesen ermöglichen, die Gelenke teilweise zu unterstützen. Elektromotoren mit hohem Drehmoment in Kombination mit minimalen Getrieben können durch menschliche Gelenke frei gedreht (d. h. rückwärts angetrieben) werden, was den Einsatz einer neuen Methode zur Drehmomentsteuerung namens Energieformung ermöglicht, um das wahrgenommene Gewicht/die Trägheit des Körpers bei jeder Bewegung zu reduzieren. Durch die Montage dieser modularen Aktuatoren an handelsüblichen Orthesen kann diese Technologie von Ärzten problemlos verschrieben/konfiguriert werden.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Muscle effort
Zeitfenster: Baseline and through study completion, an average of 2 months
Muscle activity will be measured by surface EMG electrodes, and EMG sites will be averaged by flexors and extensors. For each condition (no orthosis vs. powered orthosis), signals will be normalized by their peaks during the no-orthosis condition, and then averaged over cycle, repetitions, and tasks to obtain overall muscle effort (focusing on knee extension for the powered knee orthosis, hip extension and flexion for the powered hip orthosis, and ankle plantarflexion for the powered ankle orthosis).
Baseline and through study completion, an average of 2 months
Joint moment load
Zeitfenster: Baseline and through study completion, an average of 2 months
Biological torques will be estimated by subtracting the assistive torques from the total joint torques computed via inverse dynamics (using OpenSim). Biological torques will be divided into flexion and extension. For each condition (no orthosis vs. powered orthosis), signals will be normalized by their peaks during the no-orthosis condition, and then averaged over cycle, repetitions, and tasks to obtain overall joint moment load (focusing on knee extension for the powered knee orthosis, hip extension and flexion for the powered hip orthosis, and ankle plantarflexion for the powered ankle orthosis).
Baseline and through study completion, an average of 2 months
Pain score
Zeitfenster: Baseline and through study completion, an average of 2 months

The Knee Injury and Osteoarthritis Outcome Score (KOOS) will be used to assess perceived pain for a multi-activity circuit test and isolated activity tests.

The KOOS evaluates both short-term and long-term consequences of knee injury. It holds 42 items in 5 separately scored subscales; Pain, other Symptoms, Function in daily living (ADL), Function in Sport and Recreation (Sport/Rec), and knee-related Quality of Life (QOL). It is an extension of the WOMAC Osteoarthritis Index. A Likert scale is used and all items have five possible answer options scored from 0 (No Problems) to 4 (Extreme Problems) and each of the five scores is calculated as the sum of the items included. Scores are transformed to a 0-100 scale, with zero representing extreme knee problems and 100 representing no knee problems as common in orthopaedic assessment scales and generic measures.

Baseline and through study completion, an average of 2 months

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
10-meter walk test
Zeitfenster: Baseline and through study completion, an average of 2 months
A 10-meter walk test on an overground walkway will assess self-selected walking speed across three conditions: no orthosis, conventional orthosis, and powered orthosis at their preferred assistance level.
Baseline and through study completion, an average of 2 months
Joint range of motion
Zeitfenster: Baseline and through study completion, an average of 2 months
Joint range of motion for each task will be recorded using optical motion capture and averaged over cycle and repetitions. Motion capture data will be recorded during study visits and used to calculate joint angle, which will then be averaged over gait cycles and activity repetitions to get a range of motion value.
Baseline and through study completion, an average of 2 months
Joint compressive forces
Zeitfenster: Baseline and through study completion, an average of 2 months
In Aim 3, joint compressive forces for each task will be modeled using OpenSim / inverse dynamics and
Baseline and through study completion, an average of 2 months
Difficulty score
Zeitfenster: Baseline and through study completion, an average of 2 months

The Knee Injury and Osteoarthritis Outcome Score (KOOS) will be used to assess perceived difficulty for a multi-activity circuit test and isolated activity tests.

The KOOS evaluates both short-term and long-term consequences of knee injury. It holds 42 items in 5 separately scored subscales; Pain, other Symptoms, Function in daily living (ADL), Function in Sport and Recreation (Sport/Rec), and knee-related Quality of Life (QOL). It is an extension of the WOMAC Osteoarthritis Index. A Likert scale is used and all items have five possible answer options scored from 0 (No Problems) to 4 (Extreme Problems) and each of the five scores is calculated as the sum of the items included. Scores are transformed to a 0-100 scale, with zero representing extreme knee problems and 100 representing no knee problems as common in orthopaedic assessment scales and generic measures.

Baseline and through study completion, an average of 2 months
QUEST
Zeitfenster: Baseline and through study completion, an average of 2 months

We will administer the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0) survey after each orthosis condition to assess comfort and satisfaction with the device.

The QUEST 2.0 is a highly-validated, 12-item self-report questionnaire designed to measure how satisfied a person is with a wide range of assistive technology. It contains 12 items divided into 2 primary categories: device subscale and services subscale. Participants rate each item using a 5-point Likert scale: 1 = Not satisfied at all, 2 = Not very satisfied, 3 = More or less satisfied, 4 = Quite satisfied, 5 = Very satisfied. To calculate the final metrics, the scores of the items are summed and divided by the total number of valid responses. This yields three separate scores ranging from 1.0 to 5.0: a Device Score, a Services Score, and a Total QUEST Score. Higher scores indicate a better outcome (greater satisfaction with the technology).

Baseline and through study completion, an average of 2 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Mitarbeiter

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

18. Juli 2025

Primärer Abschluss (Geschätzt)

30. März 2030

Studienabschluss (Geschätzt)

31. März 2030

Studienanmeldedaten

Zuerst eingereicht

16. Juni 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

22. Juni 2026

Zuerst gepostet (Tatsächlich)

29. Juni 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

29. Juni 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

22. Juni 2026

Zuletzt verifiziert

1. Juni 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • HUM00201957_Period2
  • R01EB031166 (US NIH Stipendium/Vertrag)

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

UNENTSCHIEDEN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .