Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Supine Versus Prone Whole-Breast Radiotherapy in Thai Women After Breast-Conserving Surgery (SPAR-Breast)

10. November 2026 aktualisiert von: Mahidol University

Dosimetric Comparison of Supine Versus Prone Whole-Breast Radiotherapy in Thai Women After Breast-Conserving Surgery: A Prospective Paired Study

This study aims to compare two positions used for whole-breast radiation therapy in Thai women who have undergone breast-conserving surgery: lying on the back (supine) and lying face down (prone).

Radiation therapy after breast-conserving surgery helps reduce the risk of breast cancer returning. However, some radiation may reach nearby organs, particularly the heart and lungs. The position used during treatment may affect how much radiation these organs receive.

In this study, 24 women will undergo radiation treatment planning CT scans in both the supine and prone positions. Researchers will create a radiation treatment plan for each position and compare how well the plans cover the breast while minimizing radiation exposure to the heart and lungs. Each participant will receive actual radiation treatment in only one of the two positions, selected based on treatment planning results and clinical suitability.

The study will also assess patient comfort, positioning accuracy, treatment setup time, and treatment-related side effects.

The findings may help identify which patients are more likely to benefit from prone positioning and support individualized breast radiation treatment planning in Thai women.

Studienübersicht

Status

Noch keine Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

This is a prospective paired within-patient dosimetric study comparing supine and prone whole-breast radiotherapy in Thai women after breast-conserving surgery.

Each participant will undergo CT simulation in both the supine and prone positions. A three-dimensional conformal radiotherapy plan will be generated for each position using the same planning approach. The two plans will first be evaluated for acceptable target coverage. They will then be compared according to radiation exposure to organs at risk, with primary consideration given to the heart and ipsilateral lung and secondary consideration given to the contralateral lung and contralateral breast.

The treatment position used for actual radiotherapy will be selected using a predefined plan-comparison algorithm based on target coverage and organ-at-risk dose criteria. If both plans are otherwise comparable, patient preference may be used as a final decision factor. The participant will receive treatment in only one selected position.

The study will also explore whether anatomical characteristics, including chest wall and breast-related measurements, are associated with greater dosimetric benefit from prone positioning. Additional assessments include treatment setup time, positioning accuracy, patient comfort and preference, and treatment-related toxicity.

The study is intended to provide institution-specific data on individualized selection of breast radiotherapy position in Thai women rather than assuming that either supine or prone positioning is preferable for all patients.

Studientyp

Interventionell

Einschreibung (Geschätzt)

24

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Weiblich

Beschreibung

Inclusion Criteria:

  • Histologically confirmed breast carcinoma or ductal carcinoma in situ (DCIS)
  • Status post breast-conserving surgery
  • Planned adjuvant breast-only radiotherapy
  • No indication for regional nodal irradiation
  • Preoperative breast size corresponding to bra cup A-B, defined by the patient's preoperative bra size or a bust-minus-underbust circumference difference of <14 cm
  • Age ≥18 years

Exclusion Criteria:

  • Planned treatment using Deep Inspiration Breath Hold (DIBH)
  • Bilateral breast cancer
  • Previous radiotherapy to the ipsilateral breast
  • Unable to tolerate either the prone or supine position
  • Breast volume >750 cm³
  • Pre-existing heart disease or lung disease
  • Active connective tissue disease
  • Pregnant or found to be pregnant

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Supine and Prone Whole-Breast Radiotherapy Planning

All participants will undergo CT simulation and treatment planning in both the supine and prone positions. The two plans will be compared for target coverage and radiation dose to organs at risk, including the heart and ipsilateral lung. Actual whole-breast radiotherapy will be delivered in only one selected position based on predefined plan-selection criteria and clinical suitability.

Participants will undergo CT simulation in both supine and prone positions after breast-conserving surgery. Whole-breast radiotherapy plans will be generated for both positions using 3-dimensional conformal radiotherapy (3D-CRT). Target coverage and organ-at-risk dosimetric parameters will be compared between the two plans. The treatment position will be selected according to predefined target coverage and organ-at-risk criteria. Participants will receive actual radiotherapy in the selected position only. The prescribed whole-breast dose is 40 Gy in 15 fractions, with a simultaneous integrated boost to 48 Gy in selected patients.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Mean Heart Dose in Supine Versus Prone Treatment Plans
Zeitfenster: within 4 weeks after both CT simulations

Mean radiation dose to the heart, measured in Gray (Gy), will be obtained from the dose-volume histogram for both the supine and prone treatment plans within the same participant. The mean heart dose will be compared between the two positions while maintaining acceptable target coverage.

within 4 weeks after both CT simulations
Mean Ipsilateral Lung Dose in Supine Versus Prone Treatment Plans
Zeitfenster: within 4 weeks after both CT simulations

Radiation dose to the lung on the same side as the treated breast will be assessed from the dose-volume histogram for both supine and prone treatment plans. Dosimetric parameters will include mean ipsilateral lung dose, and will be compared within the same participant while maintaining acceptable target coverage.

within 4 weeks after both CT simulations

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
PTV_Eval V95 in Supine Versus Prone Treatment Plans
Zeitfenster: within 4 weeks after both CT simulations

PTV_Eval V95, defined as the percentage of PTV_Eval receiving at least 95% of the prescribed dose, will be obtained from the dose-volume histogram for both the supine and prone treatment plans within the same participant. PTV_Eval V95 will be compared between the two positions. The unit of measure is percentage (%).

within 4 weeks after both CT simulations
Treatment time from initial setup to treatment completion
Zeitfenster: within 4 weeks after treatment completion

Time required for patient positioning and setup until treatment is completed will be recorded and compared between the supine and prone positions. Time will be reported in minutes.

within 4 weeks after treatment completion
translational X Positioning Accuracy
Zeitfenster: within 4 weeks after treatment completion

Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational X axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).

within 4 weeks after treatment completion
translational Y Positioning Accuracy
Zeitfenster: within 4 weeks after treatment completion

Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational Y axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).

within 4 weeks after treatment completion
translational Z Positioning Accuracy
Zeitfenster: within 4 weeks after treatment completion

Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational Z axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).

within 4 weeks after treatment completion
Patient Satisfaction Score
Zeitfenster: within 1 hours after both CT simulations, and within 1 hours after treatment completion

Patient satisfaction will be assessed using a study-specific questionnaire. Comfort and satisfaction will be rated using a 5-point Likert scale ranging from 1 to 5, with higher scores indicating greater comfort and satisfaction with the position.

within 1 hours after both CT simulations, and within 1 hours after treatment completion
Radiation Therapist Satisfaction
Zeitfenster: within 1 hours after treatment completion

Radiation therapist satisfaction with patient positioning will be assessed using a study-specific 5-point Likert satisfaction scale for the supine and prone positions. Scores range from 1 to 5, with higher scores indicating greater radiation therapist satisfaction with the positioning technique.

within 1 hours after treatment completion
Acute Skin Toxicity using CTCAE Version 5.0 graing scale
Zeitfenster: Weekly during radiotherapy for about 3 weeks and at 1 month after treatment completion

Acute radiation-related skin toxicity will be assessed using the National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE), Version 5.0. Radiation dermatitis will be graded from Grade 0 to Grade 5, with higher grades indicating greater severity of skin toxicity.

Weekly during radiotherapy for about 3 weeks and at 1 month after treatment completion

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Hauptermittler: Tanun Jitwatcharakomol, MD, Mahidol University

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Dezember 2026

Primärer Abschluss (Geschätzt)

31. Dezember 2027

Studienabschluss (Geschätzt)

31. Dezember 2028

Studienanmeldedaten

Zuerst eingereicht

28. Oktober 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

10. November 2026

Zuerst gepostet (Tatsächlich)

16. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

16. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

10. November 2026

Zuletzt verifiziert

1. Oktober 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 683/2569(IRB1)

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .