Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Supine Versus Prone Whole-Breast Radiotherapy in Thai Women After Breast-Conserving Surgery (SPAR-Breast)

10 novembre 2026 aggiornato da: Mahidol University

Dosimetric Comparison of Supine Versus Prone Whole-Breast Radiotherapy in Thai Women After Breast-Conserving Surgery: A Prospective Paired Study

This study aims to compare two positions used for whole-breast radiation therapy in Thai women who have undergone breast-conserving surgery: lying on the back (supine) and lying face down (prone).

Radiation therapy after breast-conserving surgery helps reduce the risk of breast cancer returning. However, some radiation may reach nearby organs, particularly the heart and lungs. The position used during treatment may affect how much radiation these organs receive.

In this study, 24 women will undergo radiation treatment planning CT scans in both the supine and prone positions. Researchers will create a radiation treatment plan for each position and compare how well the plans cover the breast while minimizing radiation exposure to the heart and lungs. Each participant will receive actual radiation treatment in only one of the two positions, selected based on treatment planning results and clinical suitability.

The study will also assess patient comfort, positioning accuracy, treatment setup time, and treatment-related side effects.

The findings may help identify which patients are more likely to benefit from prone positioning and support individualized breast radiation treatment planning in Thai women.

Panoramica dello studio

Stato

Non ancora reclutamento

Condizioni

Intervento / Trattamento

Descrizione dettagliata

This is a prospective paired within-patient dosimetric study comparing supine and prone whole-breast radiotherapy in Thai women after breast-conserving surgery.

Each participant will undergo CT simulation in both the supine and prone positions. A three-dimensional conformal radiotherapy plan will be generated for each position using the same planning approach. The two plans will first be evaluated for acceptable target coverage. They will then be compared according to radiation exposure to organs at risk, with primary consideration given to the heart and ipsilateral lung and secondary consideration given to the contralateral lung and contralateral breast.

The treatment position used for actual radiotherapy will be selected using a predefined plan-comparison algorithm based on target coverage and organ-at-risk dose criteria. If both plans are otherwise comparable, patient preference may be used as a final decision factor. The participant will receive treatment in only one selected position.

The study will also explore whether anatomical characteristics, including chest wall and breast-related measurements, are associated with greater dosimetric benefit from prone positioning. Additional assessments include treatment setup time, positioning accuracy, patient comfort and preference, and treatment-related toxicity.

The study is intended to provide institution-specific data on individualized selection of breast radiotherapy position in Thai women rather than assuming that either supine or prone positioning is preferable for all patients.

Tipo di studio

Interventistico

Iscrizione (Stimato)

24

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Femmina

Descrizione

Inclusion Criteria:

  • Histologically confirmed breast carcinoma or ductal carcinoma in situ (DCIS)
  • Status post breast-conserving surgery
  • Planned adjuvant breast-only radiotherapy
  • No indication for regional nodal irradiation
  • Preoperative breast size corresponding to bra cup A-B, defined by the patient's preoperative bra size or a bust-minus-underbust circumference difference of <14 cm
  • Age ≥18 years

Exclusion Criteria:

  • Planned treatment using Deep Inspiration Breath Hold (DIBH)
  • Bilateral breast cancer
  • Previous radiotherapy to the ipsilateral breast
  • Unable to tolerate either the prone or supine position
  • Breast volume >750 cm³
  • Pre-existing heart disease or lung disease
  • Active connective tissue disease
  • Pregnant or found to be pregnant

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Supine and Prone Whole-Breast Radiotherapy Planning

All participants will undergo CT simulation and treatment planning in both the supine and prone positions. The two plans will be compared for target coverage and radiation dose to organs at risk, including the heart and ipsilateral lung. Actual whole-breast radiotherapy will be delivered in only one selected position based on predefined plan-selection criteria and clinical suitability.

Participants will undergo CT simulation in both supine and prone positions after breast-conserving surgery. Whole-breast radiotherapy plans will be generated for both positions using 3-dimensional conformal radiotherapy (3D-CRT). Target coverage and organ-at-risk dosimetric parameters will be compared between the two plans. The treatment position will be selected according to predefined target coverage and organ-at-risk criteria. Participants will receive actual radiotherapy in the selected position only. The prescribed whole-breast dose is 40 Gy in 15 fractions, with a simultaneous integrated boost to 48 Gy in selected patients.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Mean Heart Dose in Supine Versus Prone Treatment Plans
Lasso di tempo: within 4 weeks after both CT simulations

Mean radiation dose to the heart, measured in Gray (Gy), will be obtained from the dose-volume histogram for both the supine and prone treatment plans within the same participant. The mean heart dose will be compared between the two positions while maintaining acceptable target coverage.

within 4 weeks after both CT simulations
Mean Ipsilateral Lung Dose in Supine Versus Prone Treatment Plans
Lasso di tempo: within 4 weeks after both CT simulations

Radiation dose to the lung on the same side as the treated breast will be assessed from the dose-volume histogram for both supine and prone treatment plans. Dosimetric parameters will include mean ipsilateral lung dose, and will be compared within the same participant while maintaining acceptable target coverage.

within 4 weeks after both CT simulations

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
PTV_Eval V95 in Supine Versus Prone Treatment Plans
Lasso di tempo: within 4 weeks after both CT simulations

PTV_Eval V95, defined as the percentage of PTV_Eval receiving at least 95% of the prescribed dose, will be obtained from the dose-volume histogram for both the supine and prone treatment plans within the same participant. PTV_Eval V95 will be compared between the two positions. The unit of measure is percentage (%).

within 4 weeks after both CT simulations
Treatment time from initial setup to treatment completion
Lasso di tempo: within 4 weeks after treatment completion

Time required for patient positioning and setup until treatment is completed will be recorded and compared between the supine and prone positions. Time will be reported in minutes.

within 4 weeks after treatment completion
translational X Positioning Accuracy
Lasso di tempo: within 4 weeks after treatment completion

Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational X axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).

within 4 weeks after treatment completion
translational Y Positioning Accuracy
Lasso di tempo: within 4 weeks after treatment completion

Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational Y axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).

within 4 weeks after treatment completion
translational Z Positioning Accuracy
Lasso di tempo: within 4 weeks after treatment completion

Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational Z axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).

within 4 weeks after treatment completion
Patient Satisfaction Score
Lasso di tempo: within 1 hours after both CT simulations, and within 1 hours after treatment completion

Patient satisfaction will be assessed using a study-specific questionnaire. Comfort and satisfaction will be rated using a 5-point Likert scale ranging from 1 to 5, with higher scores indicating greater comfort and satisfaction with the position.

within 1 hours after both CT simulations, and within 1 hours after treatment completion
Radiation Therapist Satisfaction
Lasso di tempo: within 1 hours after treatment completion

Radiation therapist satisfaction with patient positioning will be assessed using a study-specific 5-point Likert satisfaction scale for the supine and prone positions. Scores range from 1 to 5, with higher scores indicating greater radiation therapist satisfaction with the positioning technique.

within 1 hours after treatment completion
Acute Skin Toxicity using CTCAE Version 5.0 graing scale
Lasso di tempo: Weekly during radiotherapy for about 3 weeks and at 1 month after treatment completion

Acute radiation-related skin toxicity will be assessed using the National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE), Version 5.0. Radiation dermatitis will be graded from Grade 0 to Grade 5, with higher grades indicating greater severity of skin toxicity.

Weekly during radiotherapy for about 3 weeks and at 1 month after treatment completion

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Investigatore principale: Tanun Jitwatcharakomol, MD, Mahidol University

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 dicembre 2026

Completamento primario (Stimato)

31 dicembre 2027

Completamento dello studio (Stimato)

31 dicembre 2028

Date di iscrizione allo studio

Primo inviato

28 ottobre 2026

Primo inviato che soddisfa i criteri di controllo qualità

10 novembre 2026

Primo Inserito (Effettivo)

16 novembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

16 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

10 novembre 2026

Ultimo verificato

1 ottobre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 683/2569(IRB1)

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .