Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Nasogastric Tube Insertion Using Cook Airway Exchange Catheter in Anesthetized Patients

3. Februar 2013 aktualisiert von: Hyeon-Jeong Lee, Pusan National University Hospital
we first examined whether use of tube exchange catheter during NGT insertion could increase the success rate on the first attempt of NGT insertion compared with conventional technique. We then addressed the question of whether the use of tube exchange catheter might decrease the possible occurrence of complication associated with YOON insertion.

Studienübersicht

Studientyp

Interventionell

Einschreibung (Voraussichtlich)

100

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Yangsan, Korea, Republik von
        • Rekrutierung
        • Pnuyh Anesthesia
        • Unterermittler:
          • JI WOOK YOON, PhD

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

20 Jahre bis 70 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • ASA physical status of I or II who were scheduled to undergo elective surgery of gastrointestinal tract with NGT insertion under general anesthesia were enrolled

Exclusion Criteria:

  • Patients with maxillofacial trauma, inability to adequately protect airway, and esophageal abnormalities were excluded. Pregnant patients were also excluded from the study.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Kein Eingriff: CONTROL
In the control group (Group A) inserting the lubricated NG tube through the nostril, at that time head maintained in the neutral position.
Aktiver Komparator: tube-exchanger
The tube-exchanger group (Group B) made use of tube-exchanger G36402 (CAEC, [cook medical, Bloomington, IN]) as a stylet that was lubricated and inserted within 20-F NGT until the tip of the tube-exchanger was at the tip of the NGT
Andere Namen:
  • TUBE EXCHANGER USAGE

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Number of attempt of NGT insertion
Zeitfenster: after successful insertion of NGT, within 1 hr

After anesthetic induction, in the control group inserting the lubricated NG tube through the nostril, at that time head maintained in the neutral position. The tube-exchanger group made use of tube-exchanger as stylet within 20-F NGT. Success of appropriate NGT insertion through the nostrils until 70cm of NGT was considered with gurgling sounds on the auscultation over the epigastrium when 10ml of air was injected through the NGT and gastric contents aspiration via NGT. Total number of attempts until successful NGT insertion was recorded and tried at least three times, and was considered to have failed.

Thus, procedure time would be the dependent factor of primary endpoin which could increse the success rate of NGT.

after successful insertion of NGT, within 1 hr
Procedure time of NGT insertion
Zeitfenster: after successful insertion of NGT, within 1 hr
After anesthetic induction, in the control group inserting the lubricated NG tube through the nostril, at that time head maintained in the neutral position. The tube-exchanger group made use of tube-exchanger as stylet within 20-F NGT. Success of appropriate NGT insertion was considered with gurgling sounds on the auscultation over the epigastrium when 10ml of air was injected through the NGT and gastric contents aspiration via NGT. NGT insertion time recorded when the NGT begun to insert gently through the nostrils until 70cm of NGT.
after successful insertion of NGT, within 1 hr

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
presence of bleeding of the larynx, and knotting or kinking of NGT under laryngoscopic view
Zeitfenster: after successful insertion of NGT within the time of completion of surgery, expected average within 6 hours
The investigators examined the occurrence of complication associated with NGT insertion. After successful NGT insertion, we recorded presence of bleeding of the larynx, and knotting or kinking of NGT using laryngoscopy.
after successful insertion of NGT within the time of completion of surgery, expected average within 6 hours

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn

1. Januar 2013

Primärer Abschluss (Voraussichtlich)

1. Februar 2014

Studienabschluss (Voraussichtlich)

1. Februar 2014

Studienanmeldedaten

Zuerst eingereicht

24. Januar 2013

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

31. Januar 2013

Zuerst gepostet (Schätzen)

4. Februar 2013

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Schätzen)

5. Februar 2013

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

3. Februar 2013

Zuletzt verifiziert

1. Februar 2013

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • PNU03-2013-002
  • PNUYH03-2013-002 (Andere Kennung: PUSAN NATIONAL UNIVERSITY YANGSAN HOSPITAL)

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur TUBE EXCHANGER

Abonnieren