Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Validation of the Artificial Pancreas Diabeloop Algorithm in the Hospital (WP6-1)

Diabeloop WP6-1 : Validation of the Artificial Pancreas Diabeloop Algorithm in the Hospital

To assess whether the DIABELOOP algorithm provides better glycemic control than the usual algorithm of T1D patients on pump therapy:

  • at meals, with CHO roughly assessed by the patient.
  • during and after physical activity sessions qualified as moderate by the patient.

Primary endpoint : time within the glycemic reference range. The study will be conduct with 15 patients at the following investigation centers : Corbeil Hospital, CHU of Grenoble, and CHU of Montpellier.

Studienübersicht

Status

Abgeschlossen

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

The 15 patients will have 2 visits during 24 hours (day and night), once with their usual algorithm and once with the Diabeloop system.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

17

Phase

  • Phase 2
  • Phase 3

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Evry, Frankreich, 91058
        • Centre Hospitalier du Sud Francillien
      • Grenoble, Frankreich, 38043
        • University hospital of Grenoble
      • Montpellier, Frankreich, 34295
        • University Hospital of Montpellier

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Patient type 1 diabetic for at least one year
  • Patient treated by external insulin pump for at least 6 months
  • Patients with HbA1c <9%
  • Patient affiliated with Social Security.
  • Patient able to perform two tests of physical activity of 30 minutes (one event in each treatment period);
  • aged at least 18 years Patient;
  • Patient who signed consent

Exclusion Criteria:

  • All serious disease that could interfere with the study
  • BMI > 30 kg/m2
  • insulin requirement > 2 U/kg/day
  • Patient benefiting from a measure of legal protection;
  • Pregnant or likely to be women.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Versorgungsforschung
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Kein Eingriff: unsual treatment
The patient will have his usual treatment in this arm
Experimental: The Diabeloop algorithm
In this arm, the insulin Asp(B28) dose is calculated by the algorithm based on the usual treatment of the patient, the ratio I / C, the intensity of physical activity and blood glucose sensor.
the insulin dose is calculated by the "Diabeloop" algorithm and then administered to the patient
Andere Namen:
  • NovoRapid insulin

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Time spent in blood glucose range [70-180 mg/dl]
Zeitfenster: up to 24 hours after each treatment period
comparing the time spent in [70-180 mg/dl] with usual algorithm vs Diabeloop algorithm.
up to 24 hours after each treatment period

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Time spent Blood Glucose range [80-140 mg/dl]
Zeitfenster: 24 hours after each treatment period
Comparing the time spent in range [80-140 mg/dl] with usual algorithm vs Diabeloop algorithm
24 hours after each treatment period
time spent below 70 mg/dl and above 180 mg/dl
Zeitfenster: up to 24 hours after each treatment period
up to 24 hours after each treatment period

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Sylvia Franc, MD, Centre d'Etudes et de Recherche pour l'Intensification du Traitement du Diabète
  • Hauptermittler: Ahmed DAOUDI, MD, Centre d'Etudes et de Recherche pour l'Intensification du Traitement du Diabète
  • Hauptermittler: Pierre-Yves BENHAMOU, Pr, CHU of Grenoble
  • Hauptermittler: Sandrine LABLANCHE, MD, CHU of Grenoble
  • Hauptermittler: Eric RENARD, Pr, CHU of MONTPELLIER
  • Hauptermittler: Anne FARRET, MD, CHU of MONTPELLIER

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn

1. Mai 2014

Primärer Abschluss (Tatsächlich)

1. Februar 2015

Studienabschluss (Tatsächlich)

1. Februar 2015

Studienanmeldedaten

Zuerst eingereicht

21. März 2014

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

28. März 2014

Zuerst gepostet (Schätzen)

2. April 2014

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Schätzen)

30. Juli 2015

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

29. Juli 2015

Zuletzt verifiziert

1. Juli 2015

Mehr Informationen

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Diabetes Typ 1

Klinische Studien zur Insulin, Asp(B28)-

Abonnieren