Insulin Sensitivity, Impaired Counterregulation, and Glucose Variability (BPK005)
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Virginia
-
Charlottesville, Virginia, Estados Unidos, 22903
- University of Virginia, Center for Diabetes Technology
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Type I diabetes mellitus (TIDM) (as defined by the American Diabetes Association criteria or judgment of a physician) for at least two years prior to the enrollment in the study.
- Use of an insulin pump to treat their diabetes for at least six months prior to the study.
- Ability to use a bolus calculator function with the current insulin pump with pre-defined parameters for glucose goal, carbohydrate ratio, and insulin sensitivity factor.
- Age 21 - 64 years. Adults age 65 and over are likely to have medical exclusions for the follow-up Phase 2 study, which involves induced hypoglycemia.
- Completed Phase 1 of the Institutional Review Board (IRB) #14956 "Development of a Behavioral Observer for Type 1 Diabetes Mellitus"
- Willingness to use lispro (Humalog) insulin two days prior to and during inpatient admission.
- Willingness to perform Self-Monitoring Blood Glucose (SMBG) 4 times per day at times before meals and bedtime.
- Demonstration of proper mental status and cognition for completion of the study.
Exclusion Criteria:
- Pregnancy
- Psychiatric disorders that would interfere with study tasks (e.g. mental retardation, substance abuse)
- History of a systemic deep tissue infection with methicillin-resistant staph aureus or Candida albicans
- Known bleeding diathesis or dyscrasia
- Active enrollment in another clinical trial
- Medical condition that would make operating an insulin pump difficult (e.g. blindness, severe arthritis, extensive scar tissue at sites where devices are inserted).
- Anemia (hematocrit <36% [females], <38% [males]),
- Allergy or adverse reaction to lispro (Humalog) insulin
- Conditions which may increase the risk of induced hypoglycemia such as symptomatic heart disease, congestive heart failure, history of a cerebrovascular event, atrial fibrillation, renal insufficiency (creatinine >1.5) or uncontrolled hypertension (resting blood pressure >140/90).
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: Insulin Sensitivity
Single arm.
Each subject will consume a mixed meal beverage along with insulin administration in order to calculate insulin sensitivity.
|
The subject will undergo a mixed meal and insulin challenge as follows: an insulin bolus will be administered and a mixed meal nutrition drink will be consumed over 1-5 minutes.
The mixed meal nutrition drink will be selected for that individual to be most likely to raise the glucose levels by 100mg/dl and then return to baseline within a four-hour time period.
The nutrition drink will selected from the following types of product lines: Boost products (Nestle Nutrition), Ensure products (Abbott Nutrition), Carnation Instant Breakfast (Nestle Nutrition) or Glucerna (Abbott Nutrition).The pre-meal insulin bolus will be calculated to bring the subject to ~100mg/dl at 1100.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Insulin Sensitivity
Periodo de tiempo: 24 hours
|
Measure insulin sensitivity following a mixed meal across admissions.
Insulin sensitivity was measured based on the minimal model of glucose kinetics using plasma glucose and insulin obtained frequently (approximately every 5-15 minutes) in response to mixed meal challenge.
|
24 hours
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Colaboradores
Colaboradores
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
- Trastornos del metabolismo de la glucosa
- Enfermedades metabólicas
- Enfermedades del sistema inmunológico
- Enfermedades autoinmunes
- Enfermedades del sistema endocrino
- Hiperinsulinismo
- Diabetes mellitus
- Diabetes Mellitus, Tipo 1
- Resistencia a la insulina
- Agentes hipoglucemiantes
- Efectos fisiológicos de las drogas
- Insulina
Otros números de identificación del estudio
Otros números de identificación del estudio
- 15131
- R01DK085623 (Subvención/contrato del NIH de EE. UU.)
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .