The Feasibility of Florbetapir Quantitation
The Feasibility and Reliability of Utilizing Commercially Available Quantitative Analysis Software as an Adjunct to the Clinical Qualitative Interpretation of Amyvid Brain Scans
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- Fase 4
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Pennsylvania
-
Philadelphia, Pennsylvania, Estados Unidos, 19103
- Research Site
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
- Niño
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Readers have undergone Amyvid reader training
- Readers have minimal experience with quantitation of amyloid PET scans
Exclusion Criteria:
- Readers have previously been trained to quantitate amyloid PET scans
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Único
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: Physician Readers
Physician readers will interpret Amyvid scans using qualitative analysis followed by the use of quantitation.
No subjects will be exposed to Florbetapir F 18 as part of this study.
|
No Florbetapir F 18 will be administered in this study.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Change in Total Accuracy (MIMNeuro Software, Low Accuracy Readers)
Periodo de tiempo: Scan acquired 50-60 min post-injection
|
Evaluate whether the addition of quantitation as an adjunct to qualitative interpretations (VisQ) significantly improved the total accuracy of Amyvid scan interpretation in lower accuracy readers.
Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
|
Scan acquired 50-60 min post-injection
|
|
Change in Total Accuracy (Siemens Syngo.PET Software, Experimental Arm Low Accuracy Readers)
Periodo de tiempo: Scan acquired 50-60 min post-injection
|
Evaluate whether the addition of quantitation as an adjunct to qualitative interpretations (VisQ) significantly improved the total accuracy of Amyvid scan interpretation in lower accuracy readers.
Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
|
Scan acquired 50-60 min post-injection
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Change in Total Accuracy (MIMNeuro Software, All Readers)
Periodo de tiempo: Scan acquired 50-60 min post-injection
|
Evaluate whether the total accuracy of Amyvid VisQ interpretation was non-inferior to the qualitative scan interpretation alone.
Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
|
Scan acquired 50-60 min post-injection
|
|
Change in Reliability (MIMNeuro Software)
Periodo de tiempo: Scan acquired 50-60 min post-injection
|
Evaluate whether VisQ interpretation significantly improved the reliability of Amyvid scan interpretation compared with qualitative scan interpretation alone.
The scan interpretation reliability will be evaluated using Fleiss' Kappa statistics.
|
Scan acquired 50-60 min post-injection
|
|
Change in Total Accuracy (Siemens Syngo.PET Software, Experimental Arm All Readers)
Periodo de tiempo: Scan acquired 50-60 min post-injection
|
Evaluate whether the total accuracy of Amyvid VisQ interpretation was non-inferior to the qualitative scan interpretation alone.
Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
|
Scan acquired 50-60 min post-injection
|
|
Change in Reliability (Siemens Syngo.PET Software)
Periodo de tiempo: Scan acquired 50-60 min post-injection
|
Evaluate whether VisQ interpretation significantly improved the reliability of Amyvid scan interpretation compared with qualitative scan interpretations alone.
The scan interpretation reliability will be evaluated using Fleiss' Kappa statistics.
|
Scan acquired 50-60 min post-injection
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- 18F-AV-45-QP01
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .