Studying the Performance of OCT C-scan in the Screening for Retinopathy Related to Synthetic Antimalarials (PERFOCTAPS)
Maculopathy induced by retinal toxicity of synthetic antimalarials is to be screened at the sub-clinical stage. Indeed, when the first visual symptoms appear, macular damage is already irreversible and the clinical picture may even continue to deteriorate for several years after the end of synthetic antimalarial use. In opposition, the early termination of hydroxychloroquine in patients showing recent alterations on the multifocal electroretinogram (nfERG) allowed he reversibility of toxic damage over a six month period. It is therefore critical to detect early retinal anatomic changes during retinotoxicity screening before the occurrence of irreversible anatomical and functional consequences.
The usual patient monitoring consists of an annual eye examination, detecting subjective functional abnormalities (visual acuity, color vision, central visual field testing) or macular lesions (eye fundus). These abnormalities show a constituted infringement and do not contribute to the early diagnosis of synthetic antimalarial maculopathy.
The mfERG is an objective examination, able to detect retinal damage whilst still reversible. It is recommended during the annual monitoring and is, today, the gold standard for the screening and diagnosis of synthetic antimalarial maculopathy. However, its realization is time consuming, requires a good patient cooperation and is difficult to access due to the few ophthalmology centers offering it. In practice, it is rarely done as a systematic annual screening for patients on long-term synthetic antimalarial treatment. It is often limited to second-line studies (for patients already showing functional or anatomical abnormalities) whereas its interest lies in the detection of early lesions.
The Optical Coherence Tomography Spectral Domain (OCT-SD) is a non-invasive eye examination, commonly used since nearly 10 years. A special image analysis provides a panoramic viewing of the state of the photoreceptor layer, and a non-invasive detection of any anatomical changes, even subtle, within this layer.
The concordance between the "en face" OCT and the mfERG in the screening of synthetic antimalarial maculopathy is considered in this study.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Paris, Francia, 75019
- Fondation ophtalmique Adolphe de Rothschild
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- patients treated with synthetic antimalarials for at least 5 years
Exclusion Criteria:
- state of ocular structures preventing the realization of exams
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Poner en pantalla
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: OCT C-scan
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
concordance between mfERG and SD OCT C-scan
Periodo de tiempo: 2 years
|
measure of kappa coefficient
|
2 years
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- MMT_2015_45
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .