Piting auricular a corto plazo y hemodinámica después de una cirugía cardíaca (STAPH-CS)
Estudio de Staph-CS: estimulación auricular a corto plazo y hemodinámica después de una cirugía cardíaca: una evaluación aleatoria prospectiva de estimulación auricular de tasa variable después de cirugía cardíaca con derivación cardiopulmonar
The goal of this clinical trial is to learn whether temporary atrial pacing improves heart function after cardiac surgery under cardiopulmonary bypass (CPB). It will also help determine the best pacing rate during the first 24 hours after surgery. The main questions it aims to answer are:
- Does atrial pacing improve cardiac output after surgery?
- Is 70, 80, or 90 bpm the most effective pacing rate?
- Does pacing reduce the risk of atrial fibrillation after surgery?
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
Cardiac surgery under cardiopulmonary bypass (CPB) frequently leads to immediate postoperative rhythm or conduction disturbances, especially atrial fibrillation or atrioventricular block (AV Block), along with hemodynamic instability and transient reduction in cardiac output due to myocardial contractility impairment.
Temporary pacing wires are placed in the operating room and have been used since the 1960s to manage cardiac conduction disorders in these patients, allowing for atrial (AAI) or dual-chamber (DDD) pacing if necessary. Atrial pacing, by restoring synchronized atrial contraction with ventricular filling, helps maintain optimal cardiac output.
Cardiac output is defined as the product of heart rate (HR) and stroke volume (SV). To optimize cardiac output, increasing heart rate is possible, hence the need for atrial pacing.
A pacing rate slightly higher than spontaneous sinus rhythm appears to prevent pauses, limit rhythm instability, and reduce the risk of atrial fibrillation. However, the optimal pacing rate postoperatively has not been clearly defined, and data comparing different rates (70, 80, or 90 bpm) are scarce.
In our center, postoperative atrial pacing is nearly routine and commonly set at 90 bpm, a rate we consider optimal due to its alignment with the Frank-Starling curve. This rate maximizes venous return and stroke volume, thereby optimizing postoperative cardiac output.
Nevertheless, several studies have suggested that routine postoperative temporary pacing wire insertion may not always be necessary and should be reserved for patients identified as high-risk for postoperative rhythm disturbances.
Nowadays, in many international centers, the absence of routine temporary pacing has become the norm. Although 90 bpm is theoretically the optimal rate for atrial pacing, important questions remain: Is postoperative pacing absolutely necessary? If so, could a rate lower than 90 bpm suffice to maintain adequate hemodynamic profile (HDP)?
This study aims at determining whether routine temporary pacing is necessary during the first 24 hours after cardiac surgery under CPB, and what the optimal pacing rate is (AAI or DDD: 70 bpm vs. 80 bpm vs. 90 bpm) in terms of its impact on the HDP.
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Beirut, Líbano
- Department of Anesthesia and Critical Care, Hôtel-Dieu de France Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Patients aged 18 years or older
- Cardiac surgery under CPB (coronary artery bypass grafting, valve replacement or repair, or combined procedures)
- Placement of epicardial atrioventricular pacing wires during surgery
- Placement of a Swan-Ganz catheter intraoperatively
- Signed informed consent
Exclusion Criteria:
- Emergency surgery
- Patients with an internal pacemaker
- History of permanent atrial fibrillation
- Complete atrioventricular block upon weaning from CPB
- Junctional rhythm upon weaning from CPB
- Sinus rhythm < 50 bpm upon weaning from CPB
- Failure of atrial or dual-chamber pacing (patients paced in ventricular mode VVI)
- Contraindication to Swan-Ganz catheter placement
- Hemodynamic instability defined by significant bleeding or tamponade requiring surgical re-intervention, or the need for escalating doses of vasopressors (Norepinephrine > 1 μg/kg/min, Dobutamine > 10 μg/kg/min)
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Doble
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Comparador de placebos: Pacing Group
Patients in this group receive continuous atrial pacing at 90 bpm during the first 24 postoperative hours (outside of evaluation sequences). |
At four standardized time points (H0: arrival in the ICU, H6, H12, H24), a transient pacing sequence at 70, 80, and 90 bpm is conducted, with each rate applied for 10 minutes to allow stabilization, followed by recording of the hemodynamic profile and blood pressure, as follows:
|
|
Comparador activo: Non-Pacing Group
Patients in this group remain in their spontaneous sinus rhythm outside of the evaluation sequences. |
At H0, H6, H12, and H24, they will undergo transient pacing at 70, 80, and 90 bpm, following the same measurement protocol (10 minutes per rate), followed by recording of the hemodynamic profile and blood pressure, as follows:
Outside the pacing periods at different rates, patients in the non-pacing group will remain on their spontaneous sinus rhythm. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Evaluate the impact of different pacing rates on cardiac index measured by Swan-Ganz catheter in the postoperative period following cardiac surgery under cardiopulmonary bypass at H0, H6, H12, and H24.
Periodo de tiempo: 24 hours after the surgery
|
To evaluate the impact of different pacing rates (50-69 bpm [Category 1], 70-79 bpm [Category 2], 80-89 bpm [Category 3], ≥ 90 bpm [Category 4]) on cardiac index measured by Swan-Ganz catheter in the postoperative period following cardiac surgery under cardiopulmonary bypass (CPB), at H0, H6, H12, and H24. |
24 hours after the surgery
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Determinar si la estimulación auricular reduce la incidencia de fibrilación auricular en el grupo de estimulación en comparación con el grupo de no rayos en el período postoperatorio después de la cirugía cardíaca bajo CPB
Periodo de tiempo: 24 horas después de la cirugía
|
24 horas después de la cirugía
|
|
Evaluar el impacto de las diferentes tasas de estimulación (50-69, 70-79, 80-89, ≥ 90 lpm) en el índice cardíaco medido por el catéter Swan-Gánz en pacientes con insuficiencia cardíaca después de la cirugía cardíaca bajo CPB
Periodo de tiempo: 24 horas después de la cirugía
|
24 horas después de la cirugía
|
|
Evaluar el impacto de las diferentes tasas de estimulación (50-69, 70-79, 80-89, ≥ 90 lpm) sobre la presión arterial media en el período postoperatorio después de la cirugía cardíaca bajo CPB
Periodo de tiempo: 24 horas después de la cirugía
|
24 horas después de la cirugía
|
|
Evaluar el impacto de las diferentes tasas de estimulación (50-69, 70-79, 80-89, ≥ 90 lpm) en la resistencia vascular sistémica medida por el catéter Swan-Gánz en el período postoperatorio después de la cirugía cardíaca bajo CPB
Periodo de tiempo: 24 horas después de la cirugía
|
24 horas después de la cirugía
|
|
Evaluar el impacto de las diferentes tasas de estimulación (50-69, 70-79, 80-89, ≥ 90 lpm) en el volumen de accidente cerebrovascular medido por el catéter Swan-Ganz en el período postoperatorio después de la cirugía cardíaca bajo CPB
Periodo de tiempo: 24 horas después de la cirugía
|
24 horas después de la cirugía
|
|
Evaluar el impacto de las diferentes tasas de estimulación (50-69, 70-79, 80-89, ≥ 90 lpm) en el trabajo ventricular izquierdo y derecho medido por el catéter Swan-Gánz en el período postoperatorio después de la cirugía cardíaca bajo CPB
Periodo de tiempo: 24 horas después de la cirugía
|
24 horas después de la cirugía
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Silla de estudio: Samia Jebara, Saint Joseph University of Beirut
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
Otros números de identificación del estudio
- CEHDF-2702
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .