The Use of Ultrasound to Assess the Airway Anatomy Regarding Pharyngeal Seal and Its Protective Role Throw a Chemical Test for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus) (LMA)
Ultrasonographic Mapping of the Pharyngeal Seal and Its Protective Role for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus)
The goal of this clinical trial is to to evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP), while simultaneously testing relevant safety features of regurgitation risk through salivary pH measurement.
The findings from this investigation may contribute to improved device selection and enhanced patient safety during procedures requiring supraglottic airway management.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
- Otro: evaluate the sealing quality (ProSeal LMA)using ultrasonography and a biochemical non invasive test to evaluate regurgitation
- Otro: evaluate the sealing quality of SGA device ( i-gel)using ultrasonography and a biochemical test for assessment of regurgitation
- Otro: evaluate the sealing quality of SGA device ( i-gel plus )using ultrasonography and a biochemical test for assessment of regurgitation
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Cairo, Egipto
- Faculty of medicine ain shams university
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Age 18-55 years ASA physical status I or II, BMI 18-35 kg/m² Scheduled for elective surgery that requires around (2-3 hours) duration requiring general anesthesia with an SGAD.
Exclusion Criteria:
- History of gastroesophageal reflux disease (GERD) Known or anticipated difficult airway, pathology of the mouth/oropharynx/neck, risk of aspiration.
Pregnancy.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Poner en pantalla
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Comparador activo: Group P: ProSeal.
Using computer-generated random numbers to assign patients to one of the three device groups: First group is Group P: ProSeal |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Otros nombres:
|
|
Comparador activo: Group I: i-gel.
Using computer-generated random numbers to assign patients to one of the three device groups: Second group Group I: i-gel. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Otros nombres:
|
|
Comparador activo: Group I+: i-gel Plus.
Using computer-generated random numbers to assign patients to one of the three device groups: Third group Group I+: i-gel Plus. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Ultrasound mapping of sealing efficacy with correlation to OLP
Periodo de tiempo: The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP).
|
The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Assessment for Regurgitation and microaspiration
Periodo de tiempo: Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Post insertion of device, place a Salivary Collection Device in the oropharynx via the drainage channel for 5 minutes to collect secretion. Post-operatively A sample of saliva will be collected by the anesthesiologist, and the sample PH will be checked. |
Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Ahn, J. H., Jeong, J. S., Kang, S. H., Yeon, J. E., Cho, E. A., Choi, G. S., ... & Kim, G. S. (2021). Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy: A randomized, controlled, non-inferiority study. Medicine, 100(24), e26287. Jung, Y., Jung, S., Yu, S., Jeong, M. A., & Kim, C. L. (2024). Gastric distension and atelectasis after using a supraglottic airway-A case report. Anesthesia and Pain Medicine, 19(3), 261-265. O'Riordan, C., Van De Ven, P., Nelson, J., McCreesh, K., & Clifford, A. (2016). Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging. Ultrasound, 24(3), 154-162. Solanki, S. L., Johnson, J. E., & Samantaray, A. (2020). Supraglottic airway devices: Placement and pharyngeal seal matters!. Indian Journal of Anaesthesia, 64(8), 649-652. Werner, J., Klementova, O., Bruthans, J., Macoun, J., Gaszynski, T., Henlin, T., ... & Michalek, P. (2024). Evaluation of the i-gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study. Anaesthesia, 79(12), 1284-1291. Zhang, K., Zhou, M., Zou, Z., Zhu, C., & Jiang, R. (2024). Supraglottic airway devices: a powerful strategy in airway management. American journal of cancer research, 14(1), 16., ISO 690.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- FMASU317/2025
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .