Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Device Validation of Augmented-Reality ICG Fluorescence Imaging for Sentinel Lymph Node Detection in Breast Cancer

28 de junio de 2026 actualizado por: Borislav Kondov, Ss. Cyril and Methodius University of Skopje

Validation of Augmented-Reality/Virtual-Reality Goggle-Based Near-Infrared Fluorescence Imaging for Sentinel Lymph Node Detection in Patients With Breast Cancer

This study evaluates how accurately augmented-reality goggles with indocyanine green (ICG) near-infrared fluorescence can identify sentinel (first-draining) lymph nodes during breast cancer surgery. The goggles and ICG signal are used to mark candidate sentinel nodes, and an additional observer may record near-infrared images during the operation for device-performance assessment. These imaging findings do not change the surgical procedure. The candidate nodes and all removed tissue are examined by histopathology, which serves as the reference standard. Two hundred patients undergoing breast cancer surgery will take part. The study measures how well the goggle-based imaging detects nodes that contain cancer, compared with final pathology.

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Intervención / Tratamiento

Descripción detallada

This is a prospective observational device-validation study in patients undergoing breast cancer surgery with axillary evaluation. Augmented-reality goggle-based near-infrared fluorescence imaging with ICG is used to visualize and mark candidate sentinel lymph nodes. Intraoperative near-infrared imaging may be performed by an observer who is not the operating surgeon, solely to assess device performance; observer findings are not communicated to the operating surgeon before wound closure and do not influence the operation. All marked nodes and removed tissue undergo histopathology, which serves as the blinded reference standard. Device performance is assessed on consecutive eligible patients within defined enrollment windows; for each near-infrared imaging device, sensitivity, specificity, positive and negative predictive value, and node-level ROC analysis are estimated against final histopathology, with confidence intervals accounting for clustering of nodes within patients. The study is non-interventional: the imaging does not alter surgical management.

Tipo de estudio

De observación

Inscripción (Estimado)

200

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

Ubicaciones de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Método de muestreo

Muestra no probabilística

Población de estudio

Patients with histologically proven breast cancer undergoing surgery with axillary lymph node evaluation at the participating center, enrolled consecutively.

Descripción

Inclusion Criteria:

  • Histologically proven breast cancer
  • Age 18 years or older
  • Undergoing breast cancer surgery with sentinel lymph node evaluation and/or axillary lymph node dissection
  • Provides written informed consent

Exclusion Criteria:

  • Pregnancy
  • Neoadjuvant chemotherapy
  • Prior breast surgery
  • Iodine or seafood allergy
  • Indocyanine green (ICG) allergy
  • Declines or is unable to provide informed consent

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Breast cancer patients undergoing surgery with AR-ICG node imaging
Patients undergoing breast cancer surgery in whom AR-ICG goggle-based near-infrared imaging is used to mark candidate sentinel nodes, with optional observer near-infrared imaging for device-performance assessment; histopathology is the reference standard.
Augmented-reality goggle-based near-infrared fluorescence imaging with indocyanine green (ICG), used to visualize and mark candidate sentinel lymph nodes during breast cancer surgery. Intraoperative near-infrared imaging may also be recorded by an observer for device-performance assessment. Imaging does not alter surgical management; histopathology serves as the reference standard.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Node-level diagnostic accuracy of AR-ICG fluorescence imaging versus histopathology
Periodo de tiempo: From surgery to final histopathology (up to ~2 weeks after surgery)
Sensitivity, specificity, positive and negative predictive value, and area under the ROC curve for goggle-based near-infrared fluorescence detection of tumor-positive lymph nodes, using final histopathology as the reference standard, with confidence intervals accounting for clustering of nodes within patients.
From surgery to final histopathology (up to ~2 weeks after surgery)

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Patient-level sentinel-node detection rate
Periodo de tiempo: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of patients in whom at least one sentinel lymph node is identified by AR-ICG near-infrared fluorescence imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Concordance of device-marked nodes with histopathology
Periodo de tiempo: Final histopathology (up to approximately 2 weeks after surgery)
Agreement between lymph nodes marked by AR-ICG fluorescence imaging and nodal status confirmed on final histopathology.
Final histopathology (up to approximately 2 weeks after surgery)
Per-device diagnostic performance across near-infrared imaging systems
Periodo de tiempo: Through study completion (up to approximately 24 months)
Sensitivity, specificity, positive predictive value, negative predictive value, and area under the ROC curve estimated separately for each near-infrared imaging device evaluated, using final histopathology as the reference standard, on consecutive eligible patients within defined enrollment windows.
Through study completion (up to approximately 24 months)
False-negative rate of AR-ICG fluorescence node detection
Periodo de tiempo: Final histopathology (up to approximately 2 weeks after surgery)
Proportion of pathology-confirmed tumor-positive lymph nodes not identified as fluorescent by AR-ICG imaging.
Final histopathology (up to approximately 2 weeks after surgery)
Number of candidate sentinel nodes identified per patient
Periodo de tiempo: Intraoperative (day of surgery)
Number of candidate sentinel lymph nodes marked by AR-ICG fluorescence imaging per patient (count).
Intraoperative (day of surgery)

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de julio de 2026

Finalización primaria (Estimado)

1 de julio de 2028

Finalización del estudio (Estimado)

31 de diciembre de 2028

Fechas de registro del estudio

Enviado por primera vez

28 de junio de 2026

Primero enviado que cumplió con los criterios de control de calidad

28 de junio de 2026

Publicado por primera vez (Actual)

6 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

6 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

28 de junio de 2026

Última verificación

1 de junio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • UKIM-AR-ICG-BREAST-VALID-2026

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

This is a single-center observational device-validation study. Individual participant data are not planned to be shared. De-identified data may be made available from the principal investigator on reasonable request, subject to institutional approval.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .