Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Flow Dynamics During Simulated Hemostasis at the Proximal and Distal Radial Arteries (FLOW-PRADA)

1 de julio de 2026 actualizado por: Jung-Woo Son, Wonju Severance Christian Hospital

Flow Dynamics During Simulated Hemostasis at the Proximal and Distal Radial Arteries: The FLOW-PRADA Study

Transradial access (TRA) has been widely adopted for coronary angiography and percutaneous coronary intervention, as it has been shown to significantly reduce bleeding complications, vascular complications, and mortality compared with transfemoral access (TFA). Based on this evidence, recent international guidelines recommend TRA as the preferred access strategy.

Radial artery occlusion (RAO), a potential complication following TRA, is often clinically silent and therefore underestimated. However, RAO has important clinical implications, particularly in patients who may require repeated coronary procedures, those in whom the radial artery may be used as a conduit for coronary artery bypass grafting, or patients with chronic kidney disease requiring arteriovenous fistula formation. Therefore, maintaining radial artery patency after the procedure is of considerable clinical importance.

Distal radial access (DRA), which utilizes the radial artery at the anatomical snuffbox, is a relatively recent approach. Multiple studies and meta-analyses have demonstrated that DRA provides comparable procedural success rates to TRA while significantly reducing bleeding complications and the incidence of RAO. Notably, despite the generally accepted association between smaller vessel diameter and higher risk of occlusion, DRA paradoxically shows a lower incidence of RAO. The underlying mechanism for this observation remains incompletely understood.

Sgueglia et al. evaluated peak systolic velocity using Doppler ultrasonography under conditions of arterial compression and reported that antegrade blood flow was better preserved during distal radial artery compression compared with proximal radial artery compression. This finding suggests a potential mechanistic explanation for the lower incidence of RAO observed with DRA.

However, there is a paucity of studies that systematically evaluate hemodynamic changes under simulated real-world hemostatic conditions at both proximal and distal radial arteries.

Therefore, the aim of this study is to quantitatively assess hemodynamic changes induced by simulated occlusive hemostasis at the proximal and distal radial arteries using Doppler ultrasonography, and to elucidate the mechanisms underlying the lower incidence of RAO observed with DRA.

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Intervención / Tratamiento

Tipo de estudio

De observación

Inscripción (Estimado)

220

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

  • Nombre: Jung-Woo Son
  • Número de teléfono: +82-33-741-0910
  • Correo electrónico: soneycar@gmail.com

Ubicaciones de estudio

    • Gangwon-do
      • Wŏnju, Gangwon-do, Corea del Sur, 26426
        • Wonju Severance Christian Hospital
        • Contacto:
          • Jung-Woo Son, MD
          • Número de teléfono: +82-33-741-0920
          • Correo electrónico: soneycar@gmail.com
        • Contacto:

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Niño
  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

Sí

Método de muestreo

Muestra no probabilística

Población de estudio

Adults (≥19 years) scheduled for coronary angiography for atypical chest pain, stable angina, or acute coronary syndrome, undergoing pre-procedural transthoracic echocardiography, with palpable proximal and distal radial arteries; excluding those with cardiogenic shock, prior distal radial coronary angiography before echocardiography, inability/refusal to consent, ipsilateral arteriovenous fistula, or pregnancy/breastfeeding.

Descripción

Inclusion Criteria:

A. Adults aged ≥19 years B. Patients scheduled for coronary angiography due to atypical chest pain, stable angina, or acute coronary syndrome C. Patients undergoing transthoracic echocardiography for assessment of cardiac function prior to coronary angiography D. Palpable proximal and distal radial arteries

Exclusion Criteria:

A. Cardiogenic shock B. Patients who have undergone coronary angiography via distal radial access prior to echocardiographic evaluation C. Refusal or inability to provide informed consent D. Presence of an ipsilateral arteriovenous fistula E. Pregnant or breastfeeding women

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Patent hemostasis of distal radial artery
Patent hemostasis of distal radial artery using TR band
Simulated patent hemostasis using air-filled TR band
Patent hemostasis of proximal radial artery
Patent hemostasis of proximal radial artery using TR band
Simulated patent hemostasis using air-filled TR band

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Difference in end-diastolic velocity
Periodo de tiempo: Periprocedural
Difference in end-diastolic velocity between proximal and distal radial arteries during patent hemostasis by Doppler ultrasound
Periprocedural

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Flow preservation ratio
Periodo de tiempo: Periprocedural
Flow preservation ratio in proximal and distal radial arteries
Periprocedural
Blood flow volume
Periodo de tiempo: Periprocedural
Blood flow volume in proximal and distal radial arteries
Periprocedural
Flow volume per beat
Periodo de tiempo: Periprocedural
Flow volume per beat in proximal and distal radial arteries
Periprocedural
Pulsatility index
Periodo de tiempo: Periprocedural
Pulsatility index in proximal and distal radial arteries
Periprocedural
Resistance index
Periodo de tiempo: Periprocedural
Resistance index in proximal and distal radial arteries
Periprocedural
Peak systolic velocity
Periodo de tiempo: Periprocedural
Peak systolic velocity in proximal and distal radial arteries
Periprocedural
Velocity time integral
Periodo de tiempo: Periprocedural
Velocity time integral in proximal and distal radial arteries
Periprocedural
Radial artery occlusion
Periodo de tiempo: up to 1 month
Radial artery occlusion
up to 1 month

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Investigadores

  • Investigador principal: Jung-Woo Son, Yonsei University Wonju College of Medicine, Wonju Severance Christian Hospital

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de julio de 2026

Finalización primaria (Estimado)

31 de diciembre de 2026

Finalización del estudio (Estimado)

31 de diciembre de 2026

Fechas de registro del estudio

Enviado por primera vez

24 de junio de 2026

Primero enviado que cumplió con los criterios de control de calidad

1 de julio de 2026

Publicado por primera vez (Actual)

6 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

6 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

1 de julio de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • CR326050

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .