Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Evaluation of Maxillary Buccal Miniscrew Insertion Using Digital Guides

7 de julio de 2026 actualizado por: Can Tho University of Medicine and Pharmacy
This randomized split-mouth clinical trial aims to compare the accuracy and clinical outcomes of CAD/CAM 3D-printed surgical guides with the conventional free-hand technique for orthodontic miniscrew placement in the posterior maxilla. Each participant will receive miniscrew placement using both techniques on opposite sides of the maxilla following random allocation. The primary outcome is placement accuracy assessed by three-dimensional positional and angular deviations between planned and actual miniscrew positions. Secondary outcomes include miniscrew stability, success rate after three months, postoperative pain, procedural time, patient satisfaction, and complications. The study also evaluates maxillary posterior cortical bone thickness using cone-beam computed tomography (CBCT) and investigates its relationship with miniscrew placement accuracy and stability

Descripción general del estudio

Estado

Terminado

Condiciones

Intervención / Tratamiento

Descripción detallada

Orthodontic miniscrews have become an effective source of temporary skeletal anchorage because they provide absolute anchorage with minimal dependence on patient compliance. However, the success of orthodontic miniscrews largely depends on accurate insertion while avoiding adjacent anatomical structures, particularly dental roots and the maxillary sinus. Incorrect placement may lead to root damage, instability, or failure of the miniscrew Cone-beam computed tomography (CBCT) allows three-dimensional evaluation of alveolar bone morphology and cortical bone thickness before miniscrew insertion. Digital technologies combining CBCT, intraoral scanning, CAD/CAM planning, and three-dimensional printing have enabled fabrication of customized surgical guides designed to improve insertion accuracy This study is designed as a randomized split-mouth controlled clinical trial. Patients requiring bilateral orthodontic miniscrews in the posterior maxilla will receive one miniscrew inserted using a CAD/CAM 3D-printed surgical guide and the contralateral miniscrew inserted using the conventional free-hand technique. The side allocated to each intervention and the order of insertion will be randomized Placement accuracy will be evaluated by superimposing preoperative planning data with postoperative digital models using Geomagic Studio software. Three-dimensional deviations, including coronal and apical positional deviations and angular deviations, will be calculated. Miniscrew stability, success rate after three months, postoperative pain measured by the Visual Analog Scale (VAS), patient satisfaction, operative time, and treatment-related complications will also be evaluated. Additionally, CBCT will be used to measure cortical bone thickness at multiple posterior maxillary interradicular sites, and correlations between cortical bone thickness and miniscrew accuracy and stability will be analyzed

Tipo de estudio

Intervencionista

Inscripción (Actual)

33

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Can Tho, Vietnam, +84
        • Can Tho University of Medicine and Pharmacy

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

Sí

Descripción

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Patients requiring bilateral orthodontic miniscrew placement in the posterior maxilla as part of orthodontic treatment.
  • Availability of high-quality cone-beam computed tomography (CBCT) images suitable for evaluation and digital planning.
  • Good general health and ability to undergo orthodontic treatment.
  • Healthy periodontal tissues at the planned miniscrew insertion sites.
  • Ability and willingness to provide written informed consent.

Exclusion Criteria:

  • Systemic diseases or medications affecting bone healing or bone metabolism.
  • Bleeding disorders or contraindications to minor oral surgery.
  • Active periodontal disease or local infection at the planned insertion site.
  • Poor-quality or incomplete CBCT images.
  • Contraindications to CBCT imaging.
  • Pregnancy or lactation.
  • Previous orthodontic miniscrew placement in the planned insertion area.
  • Refusal or inability to provide informed consent.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Único

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: CAD/CAM-Guided Miniscrew Placement
Miniscrew placement using a customized CAD/CAM 3D-printed surgical guide.
A customized tooth-supported CAD/CAM-designed and 3D-printed surgical guide fabricated from CBCT and intraoral scan data to assist accurate orthodontic miniscrew insertion in the posterior maxilla according to the preoperative digital treatment plan.
Comparador activo: Free-Hand Miniscrew Placement
Conventional free-hand orthodontic miniscrew placement.
Orthodontic miniscrews are inserted manually using the conventional free-hand technique without the assistance of a surgical guide, based on the clinician's clinical judgment and anatomical landmarks.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Accuracy of Orthodontic Miniscrew Placement
Periodo de tiempo: Immediately after miniscrew placement
Placement accuracy will be assessed by comparing the planned and actual miniscrew positions using digital superimposition. Coronal and apical three-dimensional deviations together with angular deviations will be calculated using Geomagic Studio software.
Immediately after miniscrew placement

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Miniscrew Success Rate
Periodo de tiempo: 3 months
Clinical success defined as stable miniscrews remaining functional for orthodontic anchorage.
3 months
Miniscrew Stability
Periodo de tiempo: Immediately after insertion, 1 week, 1 month, and 3 months.
Clinical assessment of miniscrew stability after insertion.
Immediately after insertion, 1 week, 1 month, and 3 months.
Three-Dimensional Miniscrew Displacement
Periodo de tiempo: 3 months.
Changes in miniscrew position between immediate postoperative and 3-month evaluations
3 months.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Lam Nguyen Le, Assoc. Prof., Faculty of Odonto-Stomatology, Can Tho University of Medicine and Pharmacy

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de noviembre de 2025

Finalización primaria (Actual)

1 de junio de 2026

Finalización del estudio (Actual)

1 de junio de 2026

Fechas de registro del estudio

Enviado por primera vez

7 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

7 de julio de 2026

Publicado por primera vez (Actual)

13 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

13 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

7 de julio de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • LeNguyenLam

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .