Low-Current Stimulation for Recurrent Laryngeal Nerve Protection During Thyroid Surgery
Clinical Utility of Low-Current Stimulation for Recurrent Laryngeal Nerve Protection During Thyroid Surgery: A Single-Center Prospective Randomized Interventional Study
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Yunnan
-
Kunming, Yunnan, Porcelana, 650000
- The Second Affiliated Hospital of Kunming Medical University
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Patients scheduled for thyroid surgery.
- No history of prior thyroid or neck surgery.
- Normal bilateral vocal cord mobility on preoperative electronic laryngoscopy.
- Written informed consent provided before enrollment.
Exclusion Criteria:
- Preoperative recurrent laryngeal nerve dysfunction.
- Previous neck surgery.
- Incomplete clinical data.
- Severe comorbidities precluding standardized perioperative assessment.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Prevención
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Sin intervención: Control group
Participants underwent conventional anatomical identification and preservation of the recurrent laryngeal nerve during thyroid surgery.
|
|
|
Experimental: 3 mA group
Participants underwent 3 mA low-current stimulation-assisted recurrent laryngeal nerve identification in addition to conventional anatomical identification.
|
Low-current stimulation at 3 mA was used as an adjunct to anatomical recurrent laryngeal nerve identification.
Response was judged according to visible or palpable laryngeal twitch.
|
|
Experimental: 5 mA group
Participants underwent 5 mA low-current stimulation-assisted recurrent laryngeal nerve identification in addition to conventional anatomical identification.
|
Low-current stimulation at 5 mA was used as an adjunct to anatomical recurrent laryngeal nerve identification.
Response was judged according to visible or palpable laryngeal twitch.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Number of Participants With Permanent Recurrent Laryngeal Nerve Injury Confirmed by Electronic Laryngoscopy
Periodo de tiempo: 6 months after surgery
|
Permanent recurrent laryngeal nerve injury is defined as unilateral or bilateral vocal cord paresis or paralysis detected after surgery and still present at the 6-month postoperative assessment, as confirmed by electronic laryngoscopy.
The number of participants meeting this definition will be reported.
|
6 months after surgery
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Number of Participants With Vocal Cord Paresis or Paralysis Persisting at 6 Months, as Assessed by Electronic Laryngoscopy
Periodo de tiempo: 6 months after surgery
|
Permanent recurrent laryngeal nerve injury is defined as unilateral or bilateral vocal cord paresis or paralysis detected after surgery and still present at the 6-month postoperative assessment, as confirmed by electronic laryngoscopy.
The number of participants meeting this definition will be reported.
|
6 months after surgery
|
|
Total Operative Duration in Minutes
Periodo de tiempo: Intraoperative period
|
Total operative duration will be measured in minutes from the initial skin incision to completion of skin closure.
|
Intraoperative period
|
|
Intraoperative blood loss
Periodo de tiempo: Intraoperative period
|
Estimated intraoperative blood loss measured in milliliters.
|
Intraoperative period
|
|
Duration of Postoperative Hospital Stay in Days
Periodo de tiempo: From the date of surgery until hospital discharge, assessed up to 30 days after surgery
|
Postoperative hospital stay will be calculated as the number of calendar days from the date of surgery to the date of hospital discharge.
|
From the date of surgery until hospital discharge, assessed up to 30 days after surgery
|
|
Number of Participants With Stimulation-Related Adverse Events
Periodo de tiempo: From initiation of intraoperative nerve stimulation through 30 days after surgery
|
The number of participants experiencing at least one stimulation-related adverse event will be reported.
Stimulation-related adverse events include suspected thermal injury, arrhythmia, hemodynamic instability, muscle burn, overstimulation, or suspected false-negative nerve localization, as documented in the intraoperative and postoperative medical records.
|
From initiation of intraoperative nerve stimulation through 30 days after surgery
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Siqi Li, The Second Affiliated Hospital of Kunming Medical University
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
- Enfermedades del sistema endocrino
- Enfermedades del Sistema Nervioso
- Heridas y Lesiones
- Enfermedades de las vías respiratorias
- Enfermedades Otorrinolaringológicas
- Trauma craneoencefálico
- Trauma, Sistema Nervioso
- Enfermedades de los nervios craneales
- Enfermedades de la laringe
- Lesiones de los nervios craneales
- Lesiones del nervio vago
- Lesiones del nervio laríngeo
- Enfermedades de la tiroides
- Lesiones del nervio laríngeo recurrente
Otros números de identificación del estudio
Otros números de identificación del estudio
- RLN-LCS-2024-001
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .