Comparison of Non-Calibrated Splinting Bodies and T-Marker for Complete-Arch Implant Scanning

8 de septiembre de 2026 actualizado por: Mohammed El-Sawy, Menoufia University

Accuracy of Complete-Arch Implant Scans Obtained Using Non-Calibrated Splinting Bodies and a Mobile Phone-Based Photogrammetry System (T-Marker): A Randomized Crossover Clinical Trial

This randomized crossover clinical trial aims to compare the accuracy and scanning efficiency of two digital techniques for recording implant positions in completely edentulous patients receiving implant-supported full-arch prostheses. Each participant will undergo digital impressions using both a non-calibrated splinting scan body system (IoConnect) with an intraoral scanner and a mobile phone-based photogrammetry system (T-Marker). The order of the two scanning methods will be randomized.

The primary outcome is the accuracy (trueness) of implant position recording, assessed by comparing each digital impression with a verified reference model. Secondary outcomes include the time required to complete each digital impression. The findings of this study may help determine whether these digital workflows provide accurate and efficient alternatives for complete-arch implant impressions, thereby supporting clinical decision-making in implant prosthodontics.

Descripción general del estudio

Estado

Reclutamiento

Condiciones

Intervención / Tratamiento

Descripción detallada

Detailed Description

Accurate recording of implant positions is essential for the fabrication of passively fitting implant-supported full-arch prostheses. Although intraoral scanners have demonstrated acceptable accuracy for single implants and short-span restorations, complete-arch implant scanning remains challenging because of the absence of stable anatomical landmarks, long interimplant distances, and cumulative image stitching errors. To overcome these limitations, several digital impression techniques have been developed, including splinted implant scan body systems and photogrammetry-based workflows.

Recently, non-calibrated splinting scan body systems have been introduced to improve the stability of implant scan bodies during intraoral scanning without requiring scanner-specific calibration. In parallel, mobile phone-based photogrammetry systems have emerged as simplified and more accessible alternatives for capturing implant positions. However, clinical evidence directly comparing these technologies is limited.

This prospective randomized crossover clinical trial will compare the accuracy and scanning efficiency of a non-calibrated splinting scan body workflow (IoConnect) with a mobile phone-based photogrammetry system (T-Marker) for complete-arch implant impressions. Twenty-four completely edentulous patients rehabilitated with four implant-supported multiunit abutments will undergo digital impressions using both techniques. The order of the scanning procedures will be randomized using a computer-generated randomization sequence, allowing each participant to serve as their own control.

A verified conventional splinted impression and master cast will be fabricated for each participant and digitized with a high-accuracy laboratory scanner to generate the reference dataset. Digital impressions obtained with both workflows will be compared with the reference model using three-dimensional metrology software. Trueness will be evaluated by measuring linear and angular deviations of implant positions after standardized replacement of the scan bodies with their corresponding CAD library files and construction of an identical virtual implant-supported bar for all datasets.

The primary objective is to compare the trueness of implant position acquisition between the two digital workflows. The secondary objective is to compare the effective chairside scanning time required for implant position acquisition. The results of this study are expected to provide clinical evidence regarding the accuracy and efficiency of these emerging digital workflows and to support evidence-based selection of digital impression techniques for complete-arch implant rehabilitation.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

40

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Ubicaciones de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria

  • Adults aged 18 years or older.
  • Completely edentulous maxilla rehabilitated with four well-integrated implants connected to multiunit abutments.
  • Patients presenting with a screw-retained interim implant-supported prosthesis or requiring a definitive implant-supported prosthesis.
  • Adequate implant osseointegration with no clinical signs of implant failure.
  • Ability to understand the study procedures and provide written informed consent.

Exclusion Criteria

  • Fewer than four implants supporting the maxillary prosthesis.
  • Implants located outside the maxillary arch.
  • Failed implants or implants exhibiting mobility.
  • Active peri-implant infection or suppuration.
  • Inability to tolerate intraoral scanning or comply with study procedures.
  • Refusal or inability to provide written informed consent.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Diagnóstico
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación cruzada
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Experimental: IoConnect → T-Marker
Participants first undergo complete-arch digital implant impressions using the non-calibrated splinting workflow (IoConnect), followed by the mobile phone-based photogrammetry workflow (T-Marker).
A non-calibrated splinting scan body system used with an intraoral scanner to record complete-arch implant positions. The workflow uses splinted scan bodies that are digitally merged with the soft-tissue scan to generate the definitive implant impression.
Otros nombres:
  • IoConnect Flags; True Abutment; Medit i700
A smartphone-based photogrammetry system used to capture complete-arch implant positions through optical markers attached to multiunit abutments. The system generates a digital implant position dataset for prosthetic workflow and accuracy assessment.
Otros nombres:
  • T-Marker; TruAbutment T-Marker; iPhone 15 Pro Max
Experimental: Experimental: T-Marker → IoConnect
Participants first undergo complete-arch digital implant impressions using the mobile phone-based photogrammetry workflow (T-Marker), followed by the non-calibrated splinting workflow (IoConnect).
A non-calibrated splinting scan body system used with an intraoral scanner to record complete-arch implant positions. The workflow uses splinted scan bodies that are digitally merged with the soft-tissue scan to generate the definitive implant impression.
Otros nombres:
  • IoConnect Flags; True Abutment; Medit i700
A smartphone-based photogrammetry system used to capture complete-arch implant positions through optical markers attached to multiunit abutments. The system generates a digital implant position dataset for prosthetic workflow and accuracy assessment.
Otros nombres:
  • T-Marker; TruAbutment T-Marker; iPhone 15 Pro Max

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Trueness of Complete-Arch Implant Position Recording
Periodo de tiempo: Immediately after completion of each digital impression (during the 1 day study visit).
Trueness will be assessed by comparing each experimental digital implant impression with a verified reference dataset generated from a conventional splinted impression. Three-dimensional analysis will be performed using reverse-engineering software to calculate the linear (µm) and angular (degrees) deviations of implant positions. Lower deviation values indicate greater trueness.
Immediately after completion of each digital impression (during the 1 day study visit).
Angular Deviation of Complete-Arch Implant Position Recording
Periodo de tiempo: Immediately after completion of each digital impression (during the 1 day study visit).
Angular trueness will be assessed by comparing each experimental digital implant impression with a verified reference dataset. Three-dimensional analysis will be performed using reverse-engineering software to calculate the angular deviation (degrees) of implant axes. Lower values indicate greater trueness.
Immediately after completion of each digital impression (during the 1 day study visit).

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Effective Chairside Scanning Time
Periodo de tiempo: Immediately after completion of each digital impression (during the 1 day study visit).
Time required to capture and register implant positions using each digital impression workflow, measured in seconds. Only the implant position acquisition phase will be included; soft-tissue scanning, STL export, and data processing will be excluded.
Immediately after completion of each digital impression (during the 1 day study visit).

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Mohammed Elsawy, PhD, Menoufia University

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de abril de 2026

Finalización primaria (Estimado)

1 de diciembre de 2026

Finalización del estudio (Estimado)

1 de enero de 2027

Fechas de registro del estudio

Enviado por primera vez

18 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

22 de julio de 2026

Publicado por primera vez (Actual)

23 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

9 de septiembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

8 de septiembre de 2026

Última verificación

1 de septiembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • ADMNF-0226

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .