Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

AI-Based Assessment of Chest Diseases on Chest X-ray Imaging Using DenseNet-121 and a CheXpert-Trained Model

17 de septiembre de 2026 actualizado por: Ibrahim Mohamed Ibrahim, Assiut University

AI-Based Assessment of Chest Diseases on Chest X-ray Imaging Using DenseNet-121 and a CheXpert-Trained Model: A Comparative Diagnostic Accuracy Study

Chest X-rays are widely used to detect thoracic and lung conditions, but reviewing high volumes of radiographs can lead to workload strain and variation between interpreters. Artificial intelligence (AI), particularly deep learning neural networks like DenseNet-121, has shown strong potential to assist clinicians with automated image interpretation. However, AI models trained on large international datasets, such as CheXpert, may perform differently across distinct patient populations due to variations in imaging technique, patient demographics, and disease presentation.

The primary purpose of this study is to compare the diagnostic accuracy of a DenseNet-121 model trained or fine-tuned on local data against a DenseNet-121 model pretrained on the CheXpert dataset for identifying thoracic pathologies. Both models will evaluate de-identified frontal chest radiographs from adult patients. Model predictions will be compared against a reference standard established by expert radiologist consensus, with discordant findings resolved using chest computed tomography (CT). Findings will evaluate whether local model adaptation improves diagnostic precision and workflow efficiency in clinical settings.

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Tipo de estudio

De observación

Inscripción (Estimado)

100

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

N/A

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

The study population comprises adult patients aged 18 years and older who undergo frontal chest radiography within institutional radiology departments. Eligible subjects have de-identified, diagnostic-quality frontal chest X-ray images with available reference diagnostic labels verified through expert radiologist consensus and chest CT adjudication. Pediatric cases, non-diagnostic images, incomplete metadata, and duplicate scans are excluded.

Descripción

Inclusion Criteria:

  • Adult patients aged 18 years or older.
  • Undergoing frontal chest radiography.
  • Diagnostic-quality frontal chest radiographs.
  • Availability of reference diagnostic labels (verified by expert radiologist consensus or chest CT).

Exclusion Criteria:

  • Pediatric patients (under 18 years of age).
  • Non-diagnostic or poor-quality chest radiographs.
  • Incomplete clinical or imaging metadata.
  • Duplicate radiographic images or repeat patient entries.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: COHORT
  • Perspectivas temporales: CROSS_SECTIONAL

Cohortes e Intervenciones

Grupo / Cohorte
Adult Frontal Chest Radiography Cohort

This cohort includes adult patients aged 18 years and older who undergo diagnostic-quality frontal chest radiography with available reference diagnostic labels. De-identified chest radiographs from this group are evaluated by two deep learning architectures: a study-trained/fine-tuned DenseNet-121 convolutional neural network and a CheXpert-pretrained DenseNet-121 model. Model predictions are evaluated against reference standards derived from expert radiologist consensus, with discordant cases adjudicated via chest computed tomography (CT).

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Area Under the Receiver Operating Characteristic Curve (AUROC)
Periodo de tiempo: Baseline

AUROC will be calculated to assess and compare the diagnostic performance of the study-trained DenseNet-121 model versus the CheXpert-pretrained DenseNet-121 model in detecting thoracic pathologies on frontal chest radiographs. AI predictions will be compared against the reference standard of expert radiologist consensus, with discordant findings adjudicated by chest CT. AUROC values range from 0.5 (no discrimination) to 1.0 (perfect discrimination).

Baseline

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de octubre de 2026

Finalización primaria (Estimado)

1 de octubre de 2027

Finalización del estudio (Estimado)

1 de noviembre de 2027

Fechas de registro del estudio

Enviado por primera vez

17 de septiembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

17 de septiembre de 2026

Publicado por primera vez (Actual)

22 de septiembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

22 de septiembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

17 de septiembre de 2026

Última verificación

1 de septiembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • AI Chest X-Ray Assessment

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .