Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Studying Heart Rhythms With a Wearable Sensor to Detect and Predict Seizures in People With Epilepsy (EpHR-DP)

16 de septiembre de 2026 actualizado por: Acibadem University

Heart Rhythm Analysis, Seizure Detection and Prediction Using a Textile-Based Wearable Sensor in Patients With Epilepsy

The goal of this observational study is to understand heart rhythm changes in adults with epilepsy. It will also explore whether computer programs can use heart recordings to detect or predict seizures.

The study will include 20 adults with temporal lobe epilepsy and 20 healthy volunteers. Participants with epilepsy will have ongoing seizures despite treatment with at least two suitable medicines. All participants will be 18 years or older.

In temporal lobe epilepsy, seizures start in a specific region of the brain. These seizures may spread to both sides of the brain, causing muscle stiffening and rhythmic jerking. Researchers will focus on these spreading seizures when developing seizure detection and prediction methods.

The main questions are:

  • How do heart rate and heartbeat timing differ between people with and without epilepsy?
  • How do these measures change before, during, and after seizures?
  • Can computer programs learn patterns in heart recordings to detect seizures or predict them before they start?

Researchers will compare heart rate and heart rate variability between the two groups. Heart rate variability describes changes in the time between one heartbeat and the next. They will compare recordings during rest, wakefulness, and sleep.

Participants will:

  • Wear a fabric chest band that records the heart's electrical activity.
  • Have brain activity recorded through sensors on the scalp, alongside video recording.
  • Rest quietly while awake for one hour during the recording period.

Participants with epilepsy will have recordings during their usual hospital monitoring. Healthy volunteers will have 24 hours of recording at the same hospital.

Researchers will use the brain recordings and video to identify when seizures happen. They will develop and test computer programs that learn patterns in the heart recordings.

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Intervención / Tratamiento

Descripción detallada

This prospective, single-center observational study will characterize heart rate and heart rate variability (HRV) in adults with drug-resistant temporal lobe epilepsy and explore their use in detecting and predicting focal to bilateral tonic-clonic seizures. The study combines comparisons between epilepsy participants and healthy volunteers with analyses of physiological changes surrounding seizures and development of computational models.

The planned sample comprises 20 adults with epilepsy and 20 healthy volunteers. Recruitment will use non-probability sampling. Epilepsy participants will be recruited from patients admitted for clinically indicated inpatient video-electroencephalography (video-EEG) monitoring. Healthy volunteers will be recruited through the researchers' university and professional networks, with age and sex distributions as similar as feasible to those of the epilepsy group.

Recordings will take place at Sancaktepe Şehit Prof. Dr. İlhan Varank Training and Research Hospital. A textile-based wearable chest band will record electrocardiography (ECG) simultaneously with video-EEG. Epilepsy participants will be recorded during their routine inpatient monitoring, while healthy volunteers will undergo 24 hours of recording at the same hospital. Similar equipment and recording conditions will be used in both groups to reduce methodological differences related to the recording environment, physical burden and comfort.

Both groups will complete a standardized one-hour awake resting recording on the first morning, between 09:00 and 12:00, following a 15-minute adaptation period. The timing of the last meal and caffeine and nicotine use will be recorded. Neurologists will review video-EEG recordings from both epilepsy participants and healthy volunteers to identify sleep and wakefulness. In epilepsy participants, they will evaluate interictal epileptiform discharges, seizure onset and offset, seizure classification and postictal EEG changes. In healthy volunteers, they will verify the absence of electrographic seizure activity during the recording. Analyses by sleep stage will be limited to periods that can be reliably classified.

Heart rate and HRV will be compared between groups during standardized rest, sleep and wakefulness. Within epilepsy participants, analyses will examine interictal, preictal, ictal and postictal changes while accounting for repeated observations from the same participant. Medication type, dose and timing relative to the recordings will also be considered in the analysis and interpretation of heart rate and HRV findings. Effect sizes and confidence intervals will accompany the comparisons.

Textile ECG will be the primary data source for seizure detection and prediction models. Synchronized EEG and video will provide reference annotations and may also contribute complementary information through transfer learning and multimodal modelling. Conventional machine learning and deep learning approaches will be compared, including transfer learning, adaptation using limited examples from a new patient (few-shot learning), evaluation in previously unseen patients without adaptation (zero-shot evaluation) and anomaly detection. Where appropriate, models using ECG, EEG and video separately and in combination will be compared to assess the contribution of each modality. Suitable external datasets may support model pretraining.

Model performance will be evaluated offline using separate test recordings. Patient-independent evaluations will separate participants between development and testing, while patient-specific evaluations will preserve the chronological separation of training or adaptation data from later test recordings. Related segments from the same seizure will not be split between training and testing. Recordings will be assigned to training, validation and test sets before being divided into analysis windows. Model development and tuning will exclude test recordings. Results will be summarized across cross-validation folds or repeated runs.

The sample size reflects the exploratory nature of the study and experience from related research. Statistical power to detect moderate effects may be limited. The study is intended to characterize physiological patterns, estimate effect sizes and obtain preliminary model performance estimates to inform subsequent studies. Routine clinical care will remain unchanged, and study recordings and model outputs will not guide medical decisions.

Tipo de estudio

De observación

Inscripción (Estimado)

40

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

Ubicaciones de estudio

      • Istanbul, Turquía (Türkiye), 34785
        • Sancaktepe Şehit Prof. Dr. İlhan Varank Training and Research Hospital
        • Contacto:
          • Özdem Ertürk Çetin, MD
          • Número de teléfono: +90 506 912 47 06
          • Correo electrónico: ozdemerturk@yahoo.com
        • Investigador principal:
          • Özdem Ertürk Çetin, MD

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

The planned study population comprises 20 adults with drug-resistant temporal lobe epilepsy and 20 healthy adult volunteers, all aged 18 years or older. Epilepsy participants will be recruited among people admitted for clinically indicated video-EEG monitoring at Sancaktepe Şehit Prof. Dr. İlhan Varank Training and Research Hospital in Istanbul, Türkiye. Healthy volunteers will be recruited through the researchers' university and professional networks and assessed against the eligibility criteria. They will be selected to achieve age and sex distributions as similar as feasible to those of the epilepsy group.

Descripción

Inclusion Criteria:

Epilepsy group:

  • Age 18 years or older.
  • Diagnosis of temporal lobe epilepsy and admission to the epilepsy monitoring unit for video-electroencephalography (video-EEG) monitoring.
  • Ongoing seizures despite treatment with at least two appropriately selected and tolerated antiseizure medicines at adequate doses and for adequate durations.
  • History or clinical suspicion of focal to bilateral tonic-clonic seizures.
  • Provision of written informed consent.

Healthy volunteer group:

  • Age 18 years or older.
  • No known epilepsy or history of seizures.
  • Provision of written informed consent.

Exclusion Criteria:

Epilepsy group:

  • A neurodevelopmental disorder that prevents cooperation or following instructions.
  • A physical condition that prevents placement of the chest band.
  • Inability to securely attach the electrocardiography (ECG) or EEG sensors for reliable recording.
  • Absence of an epilepsy diagnosis or identification of psychogenic nonepileptic seizures.
  • Pregnancy or breastfeeding.
  • An implanted cardiac or neurostimulation device, such as a pacemaker, vagus nerve stimulator (VNS), or deep brain stimulation (DBS) device.
  • Allergy, skin sensitivity, or a skin lesion that prevents use of the electrodes or chest band.
  • A concomitant disease or medication use that may substantially affect heart rate or heart rate variability (HRV).
  • Having been diagnosed with major depressive disorder.

Healthy volunteer group:

  • A history of epilepsy or seizures.
  • Cardiovascular disease, a condition that may cause autonomic neuropathy, or medication use that may substantially affect heart rate or HRV.
  • Allergy, skin sensitivity, or a skin lesion that prevents use of the electrodes or chest band.
  • Having been diagnosed with major depressive disorder.
  • Pregnancy or breastfeeding.

Analysis-specific provisions:

The absence of a recorded target seizure during monitoring will not by itself exclude an epilepsy participant from the study; these recordings may contribute to heart rate and HRV analyses. Recordings from participants with one or two target seizures may also contribute to patient-independent machine learning models. Patient-specific machine learning models require at least three recorded target seizures from the same participant.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: CASE_CONTROL
  • Perspectivas temporales: PROSPECTIVE

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Drug-resistant temporal lobe epilepsy

20 adults aged 18 years or older with drug-resistant temporal lobe epilepsy undergoing clinically indicated inpatient video-electroencephalography (video-EEG) monitoring. Participants have ongoing seizures despite adequate trials of at least two appropriately selected and tolerated antiseizure medicines, and a history or clinical suspicion of focal to bilateral tonic-clonic seizures. Textile-based wearable electrocardiography (ECG) will be recorded simultaneously with routine video-EEG. Recording includes a one-hour awake resting period. Routine monitoring duration and clinical care will not be changed for the study.

A textile-based wearable chest band will record electrocardiography (ECG) simultaneously with video-EEG. Epilepsy participants will wear the device during their clinically indicated inpatient monitoring, without changes to routine monitoring duration or clinical care. Healthy volunteers will undergo 24 hours of recording at the same hospital. Both groups will complete a standardized one-hour awake resting recording. ECG data will be used for heart rate and heart rate variability analyses and development and offline evaluation of seizure detection and prediction models. Study recordings and model outputs will not guide participants' medical care.

Healthy volunteers

20 healthy adults aged 18 years or older without known epilepsy or a history of seizures. Volunteers will be selected to achieve age and sex distributions as similar as feasible to the epilepsy group. Participants will undergo 24 hours of simultaneous video-electroencephalography (video-EEG) and textile-based wearable electrocardiography (ECG) at the same hospital as the epilepsy group, using a similar recording setup. Recording includes a one-hour awake resting period. Heart rate and heart rate variability will be compared with the epilepsy group.

A textile-based wearable chest band will record electrocardiography (ECG) simultaneously with video-EEG. Epilepsy participants will wear the device during their clinically indicated inpatient monitoring, without changes to routine monitoring duration or clinical care. Healthy volunteers will undergo 24 hours of recording at the same hospital. Both groups will complete a standardized one-hour awake resting recording. ECG data will be used for heart rate and heart rate variability analyses and development and offline evaluation of seizure detection and prediction models. Study recordings and model outputs will not guide participants' medical care.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Mean heart rate by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

Mean heart rate will be calculated in beats per minute for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: SDNN by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

The standard deviation of normal-to-normal heartbeat intervals (SDNN) will be calculated in milliseconds for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: RMSSD by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

The root mean square of successive differences between normal-to-normal heartbeat intervals (RMSSD) will be calculated in milliseconds for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: pNN50 by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

pNN50 is the percentage of successive normal-to-normal heartbeat interval pairs that differ by more than 50 milliseconds. It will be calculated for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: low-frequency power by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

Low-frequency (LF) power of normal-to-normal heartbeat interval variability will be calculated in milliseconds squared for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: high-frequency power by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

High-frequency (HF) power of normal-to-normal heartbeat interval variability will be calculated in milliseconds squared for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: LF/HF ratio by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

The ratio of low-frequency power to high-frequency power (LF/HF) of normal-to-normal heartbeat interval variability will be calculated for each analyzed recording period. The ratio is dimensionless. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: SD1 by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

Poincare plot SD1 is the standard deviation of normal-to-normal heartbeat interval pairs perpendicular to the line of identity. It will be calculated in milliseconds for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: SD2 by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

Poincare plot SD2 is the standard deviation of normal-to-normal heartbeat interval pairs along the line of identity. It will be calculated in milliseconds for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Heart rate variability: sample entropy by recording state
Periodo de tiempo: During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).

Sample entropy, a dimensionless measure of the irregularity of normal-to-normal heartbeat interval sequences, will be calculated for each analyzed recording period. Textile-based wearable electrocardiography (ECG) recordings will be used. Values from the standardized one-hour awake resting recording will be compared between the epilepsy and healthy volunteer groups. Sleep and wakefulness will also be compared between groups, with sleep stage analyses limited to reliably classified periods. Within epilepsy participants, interictal, preictal, ictal and postictal values will be compared using video-EEG reference annotations and accounting for repeated observations. Equal-length, technically usable segments will be analyzed under prespecified rules. Effect sizes and confidence intervals will be reported.

During one monitoring admission: approximately 48-72 hours for epilepsy participants and 24 hours for healthy volunteers, including the one-hour awake resting recording on the first morning (09:00-12:00).
Event-level sensitivity for focal to bilateral tonic-clonic seizure detection
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The percentage of eligible focal to bilateral tonic-clonic seizures confirmed by video-EEG that are correctly detected by each model: correctly detected seizures divided by all eligible reference seizures in the test recordings, multiplied by 100. Reference events will be annotated independently of ECG changes and model outputs. Alarm-to-event matching rules will be specified before outcome analysis. Performance will be evaluated by internal validation on held-out recordings, with participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Results will be reported separately by model approach, with variability across validation folds or repeated runs.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
False alarms per hour for seizure detection
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The number of detection alarms not matched to a reference seizure, divided by the total evaluable monitoring time in hours. Reference seizures will be established by independent video-EEG annotation. Alarm-to-event matching and alarm-merging rules will be specified before outcome analysis and applied consistently to held-out recordings. Performance will be evaluated by internal validation on held-out recordings, with participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Results will be reported separately by model approach, with variability across validation folds or repeated runs.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Event-level sensitivity for focal to bilateral tonic-clonic seizure prediction
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The percentage of eligible lead focal to bilateral tonic-clonic seizures correctly preceded by a model warning within the prespecified prediction timing rules. Correctly predicted lead seizures will be divided by all eligible lead seizures in the test recordings and multiplied by 100. Independent targets must be preceded by at least two seizure-free hours. The prediction horizon, seizure occurrence period and alarm-to-event matching rules will be specified before outcome analysis. Performance will be evaluated by internal validation on held-out recordings, with participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Results will be reported separately by model approach, with variability across validation folds or repeated runs.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
False alarms per hour for seizure prediction
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The number of prediction alarms not followed by an eligible reference seizure within the prespecified seizure occurrence period, divided by the total evaluable monitoring time in hours. Lead seizure eligibility, prediction horizon, seizure occurrence period and alarm-matching rules will be specified before outcome analysis. Video-EEG annotations will provide the reference events. Performance will be evaluated by internal validation on held-out recordings, with participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Results will be reported separately by model approach, with variability across validation folds or repeated runs.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Window-level classification sensitivity
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The percentage of reference-positive analysis windows classified as positive: true-positive windows divided by all reference-positive windows, multiplied by 100. Reference-positive windows represent seizure activity for detection and the prespecified preictal target for prediction. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level classification specificity
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The percentage of reference-negative analysis windows classified as negative: true-negative windows divided by all reference-negative windows, multiplied by 100. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level positive predictive value
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The percentage of positive model classifications that are reference-positive: true-positive windows divided by all predicted-positive windows, multiplied by 100. This measure is also called precision. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level negative predictive value
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The percentage of negative model classifications that are reference-negative: true-negative windows divided by all predicted-negative windows, multiplied by 100. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level F1 score
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The F1 score is the harmonic mean of window-level precision and sensitivity. It is dimensionless, ranges from 0 to 1, and is higher when classification performance is better. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level balanced accuracy
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

Balanced accuracy is the arithmetic mean of window-level sensitivity and specificity, expressed as a percentage. It gives equal weight to performance on positive and negative reference classes. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level receiver operating characteristic area under the curve
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The area under the receiver operating characteristic curve (ROC-AUC) will summarize discrimination across classification thresholds using window-level prediction scores. It is dimensionless and ranges from 0 to 1. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level precision-recall area under the curve
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The area under the precision-recall curve (AUPRC) will summarize the relationship between precision and sensitivity across classification thresholds using window-level prediction scores. It is dimensionless and ranges from 0 to 1. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Window-level classification accuracy
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The percentage of all analysis windows classified correctly: the sum of true-positive and true-negative windows divided by all evaluated windows, multiplied by 100. Accuracy will be interpreted alongside the other metrics because seizures are much less frequent than non-seizure periods. Calculated separately for seizure detection and seizure prediction classification tasks and for each model approach, using prespecified reference window labels derived from video-EEG. Evaluation will use held-out recordings, preserving participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Values will be summarized across validation folds or repeated runs, with standard deviations or appropriate confidence intervals.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Mean seizure detection latency
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

For correctly detected focal to bilateral tonic-clonic seizures, the interval from the clinical seizure onset annotated using video-EEG to the corresponding model alarm will be calculated in seconds. Mean latency will be reported for each detection model, with variability or confidence intervals. Alarm matching will follow prespecified rules. Timing will be assessed offline from time-stamped recordings and algorithm outputs; it does not represent prospective deployment of a clinical alarm. Performance will be evaluated by internal validation on held-out recordings, with participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Results will be reported separately by model approach, with variability across validation folds or repeated runs.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Mean seizure prediction lead time
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

For correctly predicted eligible lead focal to bilateral tonic-clonic seizures, the interval from the corresponding model warning to reference seizure onset will be calculated in minutes. Mean lead time will be reported for each prediction model, with variability or confidence intervals. Reference onset, lead seizure eligibility, prediction horizon, seizure occurrence period and the rule for selecting the matched warning will be specified before outcome analysis. Performance will be evaluated by internal validation on held-out recordings, with participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Results will be reported separately by model approach, with variability across validation folds or repeated runs.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.
Percentage of evaluable recording time spent in seizure warning
Periodo de tiempo: During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

The total duration of the model-defined seizure warning state divided by the total evaluable recording duration, multiplied by 100. Overlapping warning intervals will contribute only once to total warning time. The duration and timing rules defining the warning state will be specified before outcome analysis and applied consistently. This measure will be reported separately for each prediction model alongside event-level sensitivity and false alarms per hour. Performance will be evaluated by internal validation on held-out recordings, with participant-level separation for patient-independent models and separation by seizure event and time for patient-specific models. Results will be reported separately by model approach, with variability across validation folds or repeated runs.

During clinically indicated video-EEG monitoring, ordinarily 48-72 hours per epilepsy participant; performance will be assessed offline using held-out portions of these recordings.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Investigadores

  • Investigador principal: Filiz Onat, MD, PhD, Acibadem University
  • Investigador principal: Mustafa Aykut Kural, MD, PhD, Acibadem University
  • Investigador principal: Berk Can Kantarcı, MD, Acibadem University

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

15 de octubre de 2026

Finalización primaria (Estimado)

15 de octubre de 2028

Finalización del estudio (Estimado)

15 de octubre de 2028

Fechas de registro del estudio

Enviado por primera vez

16 de septiembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

16 de septiembre de 2026

Publicado por primera vez (Actual)

23 de septiembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

23 de septiembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

16 de septiembre de 2026

Última verificación

1 de septiembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 2026-13/585

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .