Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Integrating Wearable Monitoring and Clinical Data for Stroke Early Warning (WISE)

2 de noviembre de 2026 actualizado por: Affiliated Hospital of Nantong University

Integrating Wearable Monitoring and Clinical Data for Stroke Early Warning: The WISE Study

Stroke is a leading global cause of death and disability. In 2021 there were 11.9 million incident strokes (10.7-13.2 million) and 93.8 million prevalent stroke survivors (89.0-99.3 million) worldwide. The burden in China is particularly severe: stroke is the leading cause of disability-adjusted life years lost, at 45.9 million, and causes more than 2 million deaths each year. Recurrence is common after a first stroke, with reported recurrence rates ranging from 5.7% to 51.3%; approximately 7.7% of patients recur within 3 months and 10.4% within 12 months, and a cohort study of 500,000 Chinese adults found that 41% (95% CI 41%-42%) of stroke survivors had a recurrence at 5 years. Recurrent stroke is associated with higher mortality, greater disability and increased consumption of health care resources, making secondary prevention after stroke the core element of reducing recurrence and improving prognosis.

Current stroke prevention and control systems remain largely reactive. Monitoring relies mainly on the patient's subjective perception after symptom onset, emergency response is triggered by telephone calls, and there is no mechanism for pre-symptomatic active sensing or active intervention at onset. The median onset-to-door time in China is still 180-240 minutes and reperfusion treatment rates (2.4%-7%) lag behind those of developed countries. Existing risk assessment tools such as the Framingham score are static models based on demographic characteristics; they cannot reflect the spatiotemporal evolution of physiological parameters in the 24-72 hours before onset and therefore cannot detect a 'recent high-risk state'. Digital health management is mostly one-way information push without bidirectional, agent-driven interaction, resulting in low patient adherence and warning messages that rarely translate into protective action.

Wearable health-monitoring devices combined with agentic artificial intelligence offer continuous, real-time and quantifiable physiological monitoring in everyday life. However, the effectiveness, feasibility and safety of such warning and intervention systems for stroke patients, especially for secondary prevention after discharge, have not been systematically evaluated. This study therefore evaluates a stroke early-warning system based on wearable monitoring and clinical data fusion, in order to provide evidence for a digital management model for stroke prevention.

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Intervención / Tratamiento

Descripción detallada

OBJECTIVES To evaluate, in a real-world setting, the effectiveness of a stroke early-warning system based on wearable-device dynamic monitoring combined with bidirectional interaction through agentic artificial intelligence, in predicting the risk of stroke - covering both the risk of a first-ever stroke in a high-risk population and the risk of recurrence in patients after ischemic stroke. A secondary aim is to construct a stroke risk early-warning model based on fusion of wearable monitoring and clinical data.

STUDY DESIGN This is a prospective, real-world, observational cohort study with a single study group; all enrolled participants wear the wearable device and are supported by the AI early-warning system. The primary outcome measure is the incidence of stroke within 12 months. The study enrolls two clinical populations: (a) out-of-hospital individuals at high risk of stroke, and (b) patients hospitalized in the Department of Neurology of the Affiliated Hospital of Nantong University with imaging-confirmed ischemic stroke who require long-term secondary prevention medication after discharge. Recruitment takes place in the Tangzha community and at the Affiliated Hospital of Nantong University and continues until the target total sample size is reached. Enrolled participants are followed at 3, 6 and 12 months.

STUDY PROCEDURES

  1. Screening and enrollment. The research team periodically reviews the list of patients hospitalized for stroke within the previous 6 months and the stroke high-risk population screening data, and applies the pre-specified inclusion and exclusion criteria to identify potentially eligible participants.

  2. Introduction and informed consent. Trained research staff explain the purpose, procedures, potential benefits and risks, and the rights and obligations of participants to eligible individuals and their caregivers. Written informed consent is obtained voluntarily after the individual demonstrates full understanding.

  3. Baseline data collection. After enrollment, investigators collect baseline information including demographic characteristics (age, sex, education), medical history, medication use, lifestyle and related clinical data.

  4. Wearable monitoring. On top of health education and standardized discharge instructions, participants receive intensified management for prevention of first or recurrent stroke, based on dynamic monitoring with a smart band and bidirectional interaction with an AI early-warning agent. This comprises:

    • Device issue and configuration: research staff issue the smart band and complete device binding before discharge (for ischemic stroke patients) or after identification (for high-risk individuals), install the companion mobile application, and configure the personal profile and individualized discharge prescription in the system.
    • Intelligent medication reminders and adherence management: the system generates a medication reminder schedule automatically from the individualized discharge prescription or post-screening medication guidance. During follow-up the smart band sends reminders at pre-set times by vibration, on-screen prompts or mobile push notifications. The research team reviews medication records remotely at regular intervals; for participants whose adherence declines (for example, three or more consecutive missed doses), the team proactively intervenes through in-application messages or telephone contact to identify the reason and provide a targeted solution.
    • Dynamic physiological monitoring and intelligent early warning: the band continuously monitors heart rate, physical activity, sleep and other physiological parameters. When monitored values persistently deviate from individualized baseline thresholds (for example, an abnormal rise in resting heart rate or a sudden drop in daytime activity) and there is concurrent abnormality in medication records, the system uses the AI agent to push structured warning information to the patient, including a risk notice and recommended actions. If the patient does not respond to the warning or the abnormal state persists, the system simultaneously notifies the research team for manual review and proactive telephone follow-up.
    • Bidirectional proactive interaction with the AI agent: during follow-up the AI agent periodically initiates dialogue to deliver stroke knowledge question-and-answer content, lifestyle guidance and emotional support, and interacts bidirectionally with the patient (for example, asking about recent condition, feeding back abnormalities, and collecting subjective symptoms). Subsequent content and frequency are adjusted dynamically according to patient feedback, forming a closed loop of sensing - warning - interaction - action.

DATA COLLECTION Data are collected through face-to-face interviews conducted by trained neurologists or stroke center physicians with the participant or a first-degree relative. Collected information includes demographic data, lifestyle, personal disease history, medication history, imaging data, family history of stroke and other traditional risk factors. Blood pressure and heart rate are measured. The National Institutes of Health Stroke Scale (NIHSS) is used to assess the degree of neurological impairment and stroke severity, and the modified Rankin Scale (mRS) is used to assess functional status. Routine laboratory results including blood cell counts, blood lipids and fasting glucose are collected and recorded. Data are collected at baseline and at the 3-, 6- and 12-month visits as specified in the outcome measures.

PREDICTION MODELLING

The study constructs deep-learning models for stroke event early warning based on environmental, wearable and in-hospital biochemical and imaging data, including:

  • A spatiotemporal graph neural network model, in which each patient is modelled as a dynamically evolving 'risk factor graph' whose nodes represent risk factors from demographics, wearable monitoring and laboratory tests and whose edges represent physiological associations between factors (for example, coordinated change in blood pressure and blood glucose). A dual-branch architecture is planned: the spatial branch builds an initial graph structure from medical priors and introduces adaptive graph learning to adjust node connection weights dynamically; the temporal branch uses gated graph convolution to extract spatial features and then a bidirectional LSTM to model feature evolution over multiple pre-warning time windows (1-72 hours). The two branches are fused through an attention mechanism to output a risk probability. Interpretability is addressed at the node level (GNNExplainer identifies the highest-contributing risk factors), the edge level (abnormal changes in association weights before warning reveal coordinated deterioration patterns) and the temporal level (attention weights localize the key warning window).
  • A multimodal Transformer fusion model, which treats wearable time-series signals, medical imaging spatial features and structured data (demographics, laboratory tests) as three heterogeneous modalities and learns cross-modal complementary relationships through cross-modal attention, with adaptive integration of the differing time granularity of each modality (minute-level wearable data, static image structure, subclinical biochemical change). A three-encoder/fusion-decoder structure is planned: a SwinTransformer time-series encoder for multiscale temporal patterns, a 3D CNN imaging encoder for spatial anatomical features, a fully connected structured-data encoder, and a cross-modal fusion layer with multi-head cross-attention. Interpretability covers modality-level attention weights, SHAP attribution, Grad-CAM heatmaps and LIME-generated individualized explanation reports.
  • A hybrid CNN-LSTM-Attention time-series early-warning model, focused on the temporal dynamics of wearable monitoring data with demographic and laboratory data as a static baseline, designed as a lightweight model suitable for real-time deployment. The planned structure is three stacked layers: a 1D-CNN for sliding-window convolution over multi-channel physiological signals, a bidirectional LSTM (or lightweight GRU) for long-range dependencies from hours to days, and self-attention over LSTM hidden states, with time-series features concatenated with the static baseline encoding before the classification layer. Interpretability focuses on the temporal dimension through visualization of temporal attention weights, SHAP ranking of input channels, individualized heatmaps, and joint validation using Shapley values and attention scores.

MODEL PERFORMANCE EVALUATION The planned effectiveness metrics are AUC-ROC, sensitivity, specificity and PR-AUC. AUC-ROC measures the model's overall ability to discriminate between participants who do and do not experience a stroke, with a pre-specified minimum acceptable threshold of AUC >= 0.75; interpretation is AUC = 0.5 no discrimination, 0.5 < AUC < 0.7 low, 0.7 <= AUC < 0.9 moderate, AUC >= 0.9 high, AUC = 1.0 perfect. AUC will be reported with its 95% confidence interval, and time-dependent ROC methods will be used where prediction at multiple time points (3 months, 6 months, 1 year) is evaluated. Sensitivity (true positive rate) is the primary concern for stroke early warning because a missed high-risk individual may miss the optimal window for intervention, while high specificity avoids unnecessary intervention, resource use and patient anxiety; both will be reported with 95% confidence intervals at the same optimal diagnostic threshold, with the threshold chosen according to clinical need (for example, a lower threshold when sensitivity is prioritized). Because stroke is a low-incidence event, PR-AUC will be reported alongside AUC-ROC to present performance from both the balanced perspective and the minority-class perspective.

Tipo de estudio

De observación

Inscripción (Estimado)

5000

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Qiuhong Ji
  • Número de teléfono: +86-13962916293
  • Correo electrónico: jiqiuhong@ntu.edu.cn

Ubicaciones de estudio

    • Jiangsu
      • Nantong, Jiangsu, Porcelana, 226000
        • Affiliated Hospital of Nantong University
        • Contacto:

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

N/A

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

(a) imaging-confirmed ischemic stroke by cranial CT or MRI within the past 6 months, with at least one of hypertension, diabetes mellitus or atrial fibrillation; OR (b) high risk of stroke, defined as a 10-year stroke risk >= 7% calculated with the China-PAR (Prediction for ASCVD Risk in China) stroke-specific model.

Descripción

Inclusion Criteria:

  • Age >= 18 years.

  • Either (a) imaging-confirmed ischemic stroke by cranial CT or MRI within the past 6 months, with at least one of hypertension, diabetes mellitus or atrial fibrillation; OR (b) high risk of stroke, defined as a 10-year stroke risk >= 7% calculated with the China-PAR (Prediction for ASCVD Risk in China) stroke-specific model. All participants must therefore satisfy the China-PAR study inclusion requirements and provide the data needed for calculation:

    (i) age >= 35 years; (ii) no known history of cardiovascular disease (for example myocardial infarction, stroke, coronary heart disease); (iii) complete basic health data, including sex, age, current residence (urban/rural), region (north/south, delimited by the Yangtze River), waist circumference, total cholesterol, high-density lipoprotein cholesterol, systolic blood pressure, diastolic blood pressure, use of antihypertensive medication, fasting blood glucose, presence of diabetes mellitus, use of glucose-lowering medication, current smoking status, and family history of stroke.

  • Sufficient language and communication ability to understand the study and willingness to sign the informed consent form voluntarily.

  • The participant, or the participant's primary caregiver, is able to operate the smart wearable device (smart band and companion mobile application) and is willing to complete the entire follow-up schedule as required by the study.

Exclusion Criteria:

  • Expected survival < 6 months, or severe cardiac, hepatic, renal or other organ insufficiency or other severe systemic disease that, in the investigator's judgment, makes the participant unsuitable for follow-up.
  • Severe cognitive impairment, aphasia, psychiatric illness or disturbance of consciousness that prevents cooperation with the study, where no stable caregiver is available to assist with the study procedures.
  • Severe limb dysfunction, or skin allergy or another reason that prevents long-term wearing or normal use of the smart wearable device.
  • Current participation in another interventional clinical study that could affect the stroke recurrence outcome.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: COHORT
  • Perspectivas temporales: PROSPECTIVE

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Wearable monitoring with AI early-warning system

All enrolled participants at high risk of stroke and patients discharged after imaging-confirmed ischemic stroke - receive: standard health education and standardized discharge instructions, a smart band (Huawei HAY20, a Class II medical device with certified sleep apnea screening and pulse-wave atrial fibrillation/premature-beat notification software) with the companion mobile application; automated intelligent medication reminders and adherence management; continuous dynamic physiological monitoring with individualized baseline thresholds and intelligent early warning; and periodic bidirectional proactive interaction with an AI agent. Participants are followed at 3, 6 and 12 months.

Continuous wearable physiological monitoring and AI-based stroke early warning - smart band (Huawei HAY20) worn continuously, monitoring heart rate, physical activity, sleep, blood oxygen and arrhythmia screening, with the companion mobile application and AI agent providing medication reminders, structured risk warnings and bidirectional interaction.

Medication adherence management delivered by the system and the research team (automated reminders; proactive contact after three or more consecutive missed doses). Health education, lifestyle guidance and emotional support delivered through periodic bidirectional AI agent dialogue

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Number of Participants with Stroke Events within 12 Months after Enrollment
Periodo de tiempo: 12 months

Stroke Events comprise: (1) ischemic stroke, (2) hemorrhagic stroke, (3) transient ischemic attack (TIA), and (4) subarachnoid hemorrhage. Each event is adjudicated on the basis of an explicit diagnosis issued by the Department of Neurology of a secondary- or higher-level hospital together with supporting outpatient or inpatient medical records and imaging evidence.

12 months

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Number of Participants with other major cardiovascular events within 12 months after Enrollment
Periodo de tiempo: 12 months

Other major cardiovascular events within 12 months, namely (1) non-fatal myocardial infarction - defined by elevation of a cardiac biomarker, preferably troponin (cTn), with dynamic change, together with at least one piece of evidence of myocardial ischemia among symptoms, ECG changes and imaging, documented in medical records; and (2) non-fatal heart failure - defined as changes in cardiac structure and function resulting from initial myocardial injury of various causes, ultimately leading to reduced ventricular pumping function, documented in medical records.

12 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de diciembre de 2026

Finalización primaria (Estimado)

1 de diciembre de 2028

Finalización del estudio (Estimado)

30 de junio de 2029

Fechas de registro del estudio

Enviado por primera vez

27 de octubre de 2026

Primero enviado que cumplió con los criterios de control de calidad

27 de octubre de 2026

Publicado por primera vez (Actual)

2 de noviembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

4 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

2 de noviembre de 2026

Última verificación

1 de octubre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 2026-K300-01
  • 2026-K300-01 (Otro identificador: the Affiliated Hospital of Nantong University)

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .