Efficacy of Aflibercept With Sequential Laser Photocoagulation for Macular Edema Secondary to Retinal Artery Macroaneurysm.
Efficacy of Aflibercept (8 mg) With Sequential Laser Photocoagulation for Macular Edema Secondary to Retinal Artery Macroaneurysm: Retrospective Study"
Retinal arterial macroaneurysm (RAM) is an acquired dilatation of a retinal arteriole that can rupture or leak, causing hemorrhage, exudation, macular edema, and vision loss. No standardized treatment exists, and options range from observation to laser photocoagulation, anti-VEGF therapy, or both.
Laser photocoagulation closes the aneurysm directly and stops leakage. It risks vascular occlusion, temporary worsening of exudate, and scotomas, especially in an actively leaking or edematous macula.
Anti-VEGF therapy reduces vascular permeability and exudation, improving visual acuity and central macular thickness. It does not reliably close the aneurysm itself.
High-dose aflibercept 8 mg has outperformed aflibercept 2 mg in fluid resolution, durability, and dosing interval length in neovascular AMD and diabetic macular edema (PULSAR and PHOTON trials). Its role in RAM-related macular edema, particularly as a pre-laser step to reduce edema and inflammation, has not been studied.
Study rationale: The study will test whether three monthly aflibercept 8 mg loading injections followed by targeted laser to the leaking RAM is a more effective, safer, and more durable sequential strategy than either treatment alone.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
Retinal arterial macroaneurysm (RAM) is an acquired focal dilatation of a retinal arteriole, typically within the first three bifurcations, that may rupture or leak to cause hemorrhagic or exudative maculopathy with secondary macular edema and vision loss [1]. Despite its clinical significance, no standardized treatment protocol currently exists; management options range from observation to focal laser photocoagulation, anti-VEGF therapy, or a combination of both [1,2]. Laser photocoagulation directly targets the aneurysmal wall to induce closure and halt leakage, but carries risks of vascular occlusion, transient exudate worsening, and scotoma formation, particularly when applied to an actively leaking or edematous macula [2]. Anti-VEGF agents, by contrast, reduce vascular permeability and reabsorb exudation, improving visual acuity and central macular thickness, but do not reliably induce anatomical closure of the aneurysm itself [1,2].
High-dose intravitreal aflibercept 8 mg has recently demonstrated superior fluid resolution, durability, and extended dosing intervals compared with aflibercept 2 mg in neovascular age-related macular degeneration and diabetic macular edema in the pivotal PULSAR and PHOTON trials [3,4]. However, its role in RAM-associated macular edema, particularly as a pre-laser adjunct to reduce edema and inflammation before aneurysm ablation, remains unexplored.
This gap provides the rationale for the present study: to evaluate whether a loading phase of three monthly aflibercept 8 mg injections, followed by targeted laser photocoagulation of the leaking RAM site, offers a more effective, safer, and durable sequential treatment strategy for RAM-related macular edema than either modality alone
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
15 patients who were diagnosed with RAM and fulfilling study certria
Descripción
Inclusion criteria;
- Age ≥ 18 years, of either sex.
- Clinical and imaging-confirmed diagnosis of retinal arterial macroaneurysm
- Presence of macular edema secondary to RAM.
- Treatment-naïve eyes.
- Signed informed consent
Exclusion criteria:
- RAM leakage site inaccessible to laser photocoagulation.
- Significant vitreous hemorrhage.
- Known hypersensitivity to aflibercept.
- Pregnancy or breastfeeding.
- Systemic conditions precluding safe intravitreal injection.
- Media opacity precluding adequate visualization.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: COHORT
- Perspectivas temporales: RETROSPECTIVE
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Change in central macular thickness (CMT), measured by spectral-domain optical coherence tomography (SD-OCT), from baseline to the final follow-up visit following sequential aflibercept 8 mg loading doses and laser photocoagulation
Periodo de tiempo: 5 mnoths
|
Spectral-domain optical coherence tomography (SD-OCT) Heidelberg machine: central macular thickness Best-corrected visual acuity (BCVA) is measured using the ETDRS/log MAR chart. |
5 mnoths
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Colaboradores
Colaboradores
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- EASLPMESRAM
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .